Pulse-Width Modulation Strategy for Common Mode Voltage Elimination with Reduced Common Mode Voltage Spikes in Multilevel Inverters with Extension to Over-Modulation Mode

  • Pham, Khoa-Dang;Nguyen, Nho-Van
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.727-743
    • /
    • 2019
  • This paper presents a pulse-width modulation strategy to eliminate the common mode voltage (CMV) with reduced CMV spikes in multilevel inverters since a high CMV magnitude and its fast variations dv/dt result in bearing failure of motors, overvoltage at motor terminals, and electromagnetic interference (EMI). The proposed method only utilizes the zero CMV states in a space vector diagram and it is implemented by a carrier-based pulse-width modulation (CBPWM) method. This method is generalized for odd number levels of inverters including neutral-point-clamped (NPC) and cascaded H-bridge inverters. Then it is extended to the over-modulation mode. The over-modulation mode is implemented by using the two-limit trajectory principle to maintain linear control and to avoid look-up tables. Even though the CMV is eliminated, CMV spikes that can cause EMI and bearing current problems still exist due to the deadtime effect. As a result, the deadtime effect is analyzed. By taking the deadtime effect into consideration, the proposed method is capable of reducing CMV spikes. Simulation and experimental results verify the effectiveness of the proposed strategy.

Common Mode Voltage Cancellation in a Buck-Type Active Front-End Rectifier Topology

  • Aziz, Mohd Junaidi Abdul;Klumpner, Christian;Clare, Jon
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.276-284
    • /
    • 2012
  • AC/AC power conversion is widely used to feed AC loads with a variable voltage and/or a variable frequency from a constant voltage constant frequency power grid or to connect critical loads to an unreliable power supply while delivering a very balanced and accurate sinusoidal voltage system of constant amplitude and frequency. The load specifications will clearly impose the requirements for the inverter stage of the power converter, while wider ranges of choices are available for the rectifier. This paper investigates the utilization of a buck-type current source rectifier as the active front-end stage of an AC/AC converter for applications that require an adjustable DC-link voltage as well as elimination of the low-frequency common mode voltage. The proposed solution is to utilize a combination of two or more zero current vectors in the Space Vector Modulation (SVM) technique for Current Sources Rectifiers (CSR).

Common-Mode Voltage Elimination for Medium-Voltage Three-Level NPC Inverters Based on an Auxiliary Circuit

  • Le, Quoc Anh;Lee, Sangmin;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2076-2084
    • /
    • 2016
  • In this paper, a novel scheme to eliminate common-mode voltage (CMV) is proposed for three-level neutral-point clamped (NPC) inverters. In the proposed scheme, a low-power full-bridge converter is utilized to produce compensatory voltage for CMV, which is injected into an NPC inverter through a single-phase four-winding transformer. With the proposed circuit, the power range for applications is not limited, and the maximum modulation index of the inverter is not reduced. These features are suitable for high-power medium-voltage machine drives. The effectiveness of the proposed method is verified by simulation and experimental results.

A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter Induction Motor Drive System Using TMS320F240 (TMS320F240을 이용한 PWM 인버터 유도전동기 구동 시스템의 전도노이즈 저감을 위한 스위칭 기법)

  • 박규현;김이훈;원충연;김규식;최세완;함년근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.89-97
    • /
    • 2003
  • High frequency common mode voltage produced by PWM inverter fed Induction motor is a major cause of conducted EMI, creation motor ground currents, bearing currents and other harmful products. The zero switching states of inverter control invoke large in comparison with the non-zero switching state of Inverter control. We proposed a common mode voltage reduction method based on sinusoidal PWM technique. PWM signal are generated by comparing respective sinusoidal reference signal with three triangular carrier wave displaced of 120$^{\circ}$. Simulation and experimenta1 result show that common mode voltages in the proposed PWM technique are reduced by approximate 66% more than conventional FWM technique.

Analysis of Common Mode Voltages at Diode Rectifier/Z-Source Inverter System (다이오드 정류기/Z-소스 인버터 시스템의 공통모드 전압 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 2009
  • In this paper, when ac motors are driven by the diode rectifier/Z-source inverter system, the common-mode voltages of system are analyzed in details under both the shoot-through state and non-shoot-through state through equivalent circuits. Then a modified space vector modulation strategy is suggested for attenuating the negative common-mode voltage by eliminating the zero voltage vector, and also controlling the shoot-through time. Through the simulation studies with PSIM and experiments with 32-bit DSP, it is verified that the negative common-mode voltage can be reduced by more than 50%.

EMI Noise Reduction with New Active Zero State PWM for Integrated Dynamic Brake Systems

  • Baik, Jae-Hyuk;Yun, Sang-Won;Kim, Dong-Sik;Kwon, Chun-Ki;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.923-930
    • /
    • 2018
  • Based on the application of an integrated dynamic brake (IDB) system that uses a PWM inverter fed-AC motor drive to operate the piston, a new active zero state PWM (AZSPWM) is proposed to improve the stability and reliability of the IDB system by suppressing the conducted electro-magnetic interference (EMI) noise under a wide range of load torque. The new AZSPWM reduces common-mode voltage (CMV) by one-third when compared to that of the conventional space vector PWM (CSVPWM). Although this method slightly increases the output current ripple by reducing the CMV, like the CSVPWM, it can be used within the full range of the load torque. Further, unlike other reduced common-mode voltage (RCMV) PWMs, it does not increase the switching power loss. A theoretical analysis is presented and experiments are performed to demonstrate the effectiveness of this method.

Technique of Common Mode Voltage and Conducted EMI Reduction using Nonzero-vector State in SVPWM Method (SVPWM방식에서의 영벡터 제거에 의한 커먼모드 전압 및 전도성 EMI 저감 기법)

  • Hahm Nyon-Kun;Kim Lee-Hun;Jeon Kee-Young;Chun Kwang-Su;Won Chung-Yuen;Han Kyung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.507-515
    • /
    • 2004
  • With the advent of fast power devices, the high dv/dt voltage produced by PWM inverts have been found to cause EMI noise, shaft voltage and bearing current. This paper describes the application of newly developed Conducted EMI reduction SVPWM technique in induction motor drives. The newly developed common mode voltage reduction SVPWM technique don't use any zero-vector states for inverter control, hence it can restrict the common mode voltage more than conventional PWM technique. The validity of the proposed technique by software approach is verified through simulation and experimental results.

A New Reduced Common-mode Voltage SVM Method for Indirect Matrix Converters with Output Current Ripple Minimization

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.383-384
    • /
    • 2015
  • This paper presents a new space vector modulation (SVM) method for indirect matrix converters (IMCs) to reduce commonmode voltage as well as minimize output current ripple in a high voltage transfer ratio. In the proposed SVM, the three-vector modulation scheme is used in the rectifier stage, while the nonzero state modulation technique, where the three nearest active vectors are selected to synthesize the desired output voltage, is applied to inverter stage to reduce the CMV. The proposed SVM method can significantly reduce the output current ripple and common-mode voltage of the IMC without any extra hardware. Simulated results are provided to demonstrate the effectiveness of the proposed SVM method.

  • PDF

A Model Predictive Control Method to Reduce Common-Mode Voltage for Voltage Source Inverters

  • Vu, Huu-Cong;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.209-210
    • /
    • 2015
  • This paper presents a new model predictive control method without the effect of a weighting factor in order to reduce common-mode voltage (CMV) for a three-phase voltage source inverter (VSI). By utilizing two active states with same dwell time during a sampling period instead of one state used in conventional method, the proposed method can reduce the CMV of VSI without the weighting factor. Simulation is carried out to verify the effectiveness of the proposed predictive control method with the aid of PSIM software.

  • PDF

A Switching Technique for Common Mode Voltage Reduction of 2-Level Inverter

  • Yun Hwan-Kyun;Kim Lee-Hun;Kim Jun-Ho;Won Chung-Yuen;Choi Gi-Su;Bae Joung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.438-442
    • /
    • 2001
  • Much attention has given to EMI effects created by variable speed ac drive system. This paper focuses on the switching technique to mitigate common mode voltage. Zero switching states of inverter control invoke large common mode voltage. Using inversed carrier wave, zero switching states are removed. In addition, proposed technique is easy to apply to existing 2-level inverter design. And common mode mitigation technique for sinusoidal PWM is also presented. Proposed switching technique is implemented with a 2.2kw 1735rpm induction motor.