• Title/Summary/Keyword: Common-Use System

Search Result 1,082, Processing Time 0.027 seconds

Multi-type, multi-sensor placement optimization for structural health monitoring of long span bridges

  • Soman, Rohan N.;Onoufrioua, Toula;Kyriakidesb, Marios A.;Votsisc, Renos A.;Chrysostomou, Christis Z.
    • Smart Structures and Systems
    • /
    • v.14 no.1
    • /
    • pp.55-70
    • /
    • 2014
  • The paper presents a multi-objective optimization strategy for a multi-type sensor placement for Structural Health Monitoring (SHM) of long span bridges. The problem is formulated for simultaneous placement of strain sensors and accelerometers (heterogeneous network) based on application demands for SHM system. Modal Identification (MI) and Accurate Mode Shape Expansion (AMSE) were chosen as the application demands for SHM. The optimization problem is solved through the use of integer Genetic Algorithm (GA) to maximize a common metric to ensure adequate MI and AMSE. The performance of the joint optimization problem solved by GA is compared with other established methods for homogenous sensor placement. The results indicate that the use of a multi-type sensor system can improve the quality of SHM. It has also been demonstrated that use of GA improves the overall quality of the sensor placement compared to other methods for optimization of sensor placement.

Transmission Error Analysis of ZI and ZA Profile Worm Gears (ZI 및 ZA형 웜기어의 치합전달오차 해석)

  • Lee, Tae-Hoon;Suh, Junho;Park, Noh-Gill
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.325-331
    • /
    • 2018
  • Automobiles and systems requiring high gear ratios and high power densities generally use worm gears. In particular, as worm gears have a small volume and self-locking function, home appliances such as refrigerators and washers consist of worm gears. We can classify worm gears into cylindrical worms and rectangular worms. According to the AGMA standard, there are four types of cylindrical worms, ZA, ZN, ZK and ZI, depending on the machining of the worm shaft. It is preferable to use a ZI-type worm shaft, which is a combination of a worm wheel having an involute helical tooth surface and a conjugate tooth surface. However, in many cases, industries mostly use ZK, ZN, and ZA worm shafts because of the ease of processing. This paper presents numerical approaches to produce ZI and ZA worm surfaces and worm wheel. For the analysis of the transmission error of a worm gear system, this study (1) generates surface profile functions of ZI profile worm gear and worm shaft based on the common rack theory, (2) adopts the Newton-Raphson method for the analysis of the gear surface contact condition, and (3) presents and compares the corresponding transmission errors of ZI and ZA worm gears.

A comprehensive review on Tukhme Kunjud (Sesamum indicum Linn.) with special reference to Unani System of Medicine.

  • Khatoon, Rizwana;Abbasi, Hana;Aslam, Mohammad;Chaudhary, Shahid Shah
    • CELLMED
    • /
    • v.9 no.3
    • /
    • pp.2.1-2.7
    • /
    • 2019
  • Sesame (Sesamum indicum L.) is a rich source of edible oil most commonly it is used as a food product mainly in bakeries and also use as a common source of oil in daily kitchen needs. Due to the presence of some special phytochemicals like proteins, fibers, oil, minerals and antioxidants it is highly used for medicinal and therapeutic purposes. It is a good source of energy and act as an antiaging agent. Its seeds are used as Anti-helmintic, antihypertensive, antimicrobial, cytotoxic and Hepatoprotective but its seed coat which is a byproduct of sesame and a cherished source of fibers is normally use for animal feedstuff. In Unani system of medicine it is used both as drug & diet (dawa wa ghida). In classical Unani literature it is indicated in various disorders like Asthma, Dry Cough, Gastritis (due to any drug, excessive use of alcohol), Dryness of Intestine, Dryness in throat, Renal Stone, Bleeding Piles, Amenorrhea, Retention of urine, Dysuria, Orchitis, Sexual Debility, Anorexia. The present review article, an attempt have been made to compile all the pharmacological and Pharmacognostical characters of Sesamum indicum with special reference to Unani literature.

A Mu1ti-Agent Platform for Providing Intelligent Medical Information (지능형 의료 정보 제공을 위한 멀티 에이전트 플랫폼)

  • 최원기;김일곤
    • Journal of Intelligence and Information Systems
    • /
    • v.7 no.1
    • /
    • pp.123-133
    • /
    • 2001
  • Medical domain is very applicable for multi-agent system because medical information systems need much knowledge and close relationship with medical staff, In this paper, we describe design and implementation of an intelligent medical multi-agent platform that provides medical images'information services. This platform supports a physical environment that medical agents can be deployed following FIPA(Foundation for Intelligent Physical Agent)\`s agent management reference model. To use a variety of components on Windows, COM(Common Object Model) interfaces and XML(extensible Markup Language) for encoding ACL(Agent Communication Language) are used for multi-agent communications. Since many kinds of diverse and close relationships with medical staff) are essential, a medical staff is conceptualized as an agent and integrated with multi-agent systems. Also it provides an infrastructure applicable to share necessary knowledge between human agents and software agents in order to make intelligent medical information services easier.

  • PDF

Field Survey on Construction and Utilization of Home Network - Focusing on Pangyo New Town - (홈네트워크 구축현황 및 이용실태 조사연구 - 판교신도시를 중심으로 -)

  • Yim, Mi-Sook
    • Journal of the Korean housing association
    • /
    • v.27 no.5
    • /
    • pp.25-35
    • /
    • 2016
  • he objective of this study was to investigate home network systems presently applied in multi-housing complexes and resident's usage to improve the utilization of these systems and services as well as maintenance methods. Subjects were 27 housing complexes equipped with home network systems in west Pangyo area. The investigation methods of communal network systems were observed and photographed. Unit systems were investigated through photography, interviews, and observation focusing on the utilization of Wall-Pads by visiting one unit of each housing complex. The results are as follows: (1) Most housing complexes that we investigated were built with high-grade IT infrastructure. Also, remote meter reading, electronic security, vehicle access, and building access systems were established. Wall-Pads with similar functions were installed in 23 housing complexes, excluding private rental housing complexes. (2) Even though people were well aware of the need for common systems within their housing complexes, only 10~20% of Wall-Pad menus were used. (3) Low utilization rates of home network stem from Wall-Pad menus which were user-unfriendly, and a lack of user training for the complex's common system and unit system. Therefore, to promote active use of home network systems, the systems must be diversified in accordance with user characteristics. In addition, the Wall-Pad menus should be reorganized to be user-friendly.

Morphological classification of the moderator band and its relationship with the anterior papillary muscle

  • Lee, Ju-Young;Hur, Mi-Sun
    • Anatomy and Cell Biology
    • /
    • v.52 no.1
    • /
    • pp.38-42
    • /
    • 2019
  • This study investigated and classified the various types of moderator band (MB) in relation to the anterior papillary muscle, with the aim of providing anatomical reference information and fundamental knowledge for use when repairing the congenital defects and understanding the conduction system. The study investigated 38 formalin-fixed human hearts of both sexes obtained from donors aged 38-90 years. The MB was evident in 36 of the 38 specimens (94.7%). The morphology of the MB and its connection with the APM took various forms. The MBs that had a distinct shape were classified into three types according to their shape: cylindrical column, long and thin column, and wide and flat column. Types 2 and 3 were the most common, appearing in 15 (41.7%) and 14 (38.9%) of the 36 specimens, respectively, while type 1 was observed in seven specimens (19.4%). Type 3 was divided into subtypes based on their length. The MB usually originated from a single root (91.7%), with the remainder exhibiting double roots. The pairs of roots in the latter cases had different shapes. The originating point of the MB ranged from the supraventricular crest to the apex of the ventricle. The most-common originating point was in the middle (25 of 36 specimens, 69.4%), followed by the upper third (13.9%), the lower third (11.1%), and the top fifth (5.6%) of the interventricular septum. This study has produced fundamental anatomical and clinical information that will be useful when designing cardiac surgical procedures.

EMC Debugging Technique for Image Equipments (영상기기의 EMC Debugging 기술)

  • Song, Min-jong;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.143-148
    • /
    • 2022
  • For the purpose of treating health checkups and recovery of patients in a super-aged society, hospitals use devices designed with a reduction circuit of electromagnetic waves associated with the specific absorption rate of electromagnetic waves absorbed by the human body. In this paper, we proposed a filter improvement design method capable of reducing electromagnetic waves. As a result of confirming the validity of the proposed technique through simulation and experimental results, the following result values were obtained. Applying the common-mode (CM) inductor 4 mH to a calibration circuit, noise decreased in a multiband spectrum. Using the differential mode(DM) inductor 40 µH element in the primary calibration circuit, the noise decreased by 15 dB or more in the 3 MHz band spectrum. Also, applying the Admittance Capacitance (Y-Cap) 10 nF element in the secondary calibration circuit resulted in the decrease by more than 30 dB in the band spectrum before 2 MHz. After using a common-mode inductor 4 mH element in the tertiary calibration circuit, it decreased by more than 15 dB in the band spectrum after 2 MHz.

New idea about realizing automatic collision avoidance on the sea

  • Yao, Jie;Wu, Zhaolin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2001.10a
    • /
    • pp.65-74
    • /
    • 2001
  • The rapid development of computer technology and widely application of artificial intelligent provide technology support for realizing navigation automation on the sea. which has achieved great success in shipping advanced countries like japan, England, America, Germany and also in the developing country, China. However, it still remains in the studying Period up to now in aspects of collision avoidance decision-making mathematical model and reasoning mechanism. In this paper, approaches are proposed to establish the collision avoidance automation system. One of them is based on the former studies to realize automation system by make use of finite state machine theory and following the International regulations for Preventing Collision at Sea, 1972. The others are to establish the new idea about automatic collision avoidance system by taking advantage of the free flight idea, hybrid system, game theory used in air traffic management studies in recent years and the common characteristics in both air and sea traffic management.

  • PDF

Trends of High Speed Satellite Offline Telemetry Processing (위성 상태 데이터의 고속 후처리 기술 동향)

  • Kang, Ji-Hoon;Koo, In-Hoi;Ahn, Sang-Il
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.15-23
    • /
    • 2010
  • In this paper, the trends of a satellite offline telemetry processing system had been discussed. The satellite offline telemetry processing system is used to analyze an offline telemetry and to check health status of the satellite. Common requirements for the system are high speed processing, processed data visualization, easiness of use, and generality. Regarding to these requirements, how the recent telemetry processing system had been designed and implemented is discussed in detail.

  • PDF

Development of Tool selection System for Machining Model Part of Injection Mold (사출금형 형상부 가공을 위한 공구 선정 시스템 개발)

  • 양학진;김성근;허영무;양진석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.569-574
    • /
    • 2002
  • As consumer's desire becomes various, agility of mold manufacturing is most important factor for competence of manufacturer. In common works to use commercial CAM system to generate tool path, some decision making process is required to produce optimal result of CAM systems, The paper proposes a methodology for computer-assisted tool selection procedures for various cutting type, such as rough, semi-rough and finish cuts. The system provides assist-tool-items for machining of design model part of injection meld die by analyzing sliced CAD model of die cavity and core. Also, the generating NC-code of the tool size is used to calculate machining time. The system is developed with commercial CAM using API. This module will be used for optimization of tool selection and planning process.

  • PDF