• Title/Summary/Keyword: Common Ground System

Search Result 187, Processing Time 0.031 seconds

A Study on a Shielding Effect of the Messenger Wires in Distribution Lines (배전선로에서의 조가선 차폐 효과 연구)

  • Kim, In-Soo;Han, Woong;Yeo, Sang-Min;Kim, Chul-Hwan;Weon, Bong-Ju;Lim, Yong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

Digital Photogrammetry Camera Boresight Calibration Using Ground Control Points (지상기준점을 이용한 디지털카메라 Boresight Calibration)

  • Lee, Yong Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.293-298
    • /
    • 2014
  • Recently, the direct georeferencing has been becoming a common method in the aerial photogrammetry. As this direct georeferencing method using converged sensor of the digital photogrammetry camera and GPS(Global Positioning System)/INS(Inertial navaigation System), more rapid and accurate aerial photogrammetry has improved following advanced performance in photogrammetry. Since the accuracy of EO parameters from the direct georeferencing is determined by GPS/INS accuracy, it is significant to calculate the exact attitude information using values of INS rotations. For following calculations, the misalignment, such as INS rotation and the gap of GPS/INS, has to be decided. Because the number of ground control points are used for tirangulation and boresight calibration, those results should be different according to array and location of ground control points. In the study, those location and array of ground control points were tested to be used boresight calibration. As a result, there is no significant change of misalignment and exterior orienation parameters in the case when ground control points were at all course. On the contrarily, the difference has been shown in the case of no ground control point at course.

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

The Characteristics of Maximum Tolerable Voltage about Earth-Layer Structure in the Grounding System (접지시스템에서 지층구조의 변화에 대한 최대 허용전압의 특성)

  • Shim, Keon-Bo;Kim, Kung-Chul;Lee, Hyung-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.254-259
    • /
    • 2007
  • During the ground fault conditions, the flow of current to earth will produce potential gradients within and arround a substation. The common physiological effects of electric current on the body, stated in order of increasing current magnitude, are threshold perception, muscular contraction, unconsciousness, fabrillation of the heart. In this study, determined the tolerable voltage about earth-layered structure in the grounding system.

  • PDF

Analysis of doubly-fed induction generator based wind power system for voltage sag (배전선로 전압강하에 대한 이중 여자 풍력발전시스템 특성 해석)

  • Cha, Han-Ju;Lee, Sang-Hoey
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1234-1235
    • /
    • 2007
  • This paper represents the generating principles of the doubly-fed induction generator (DFIG) based wind power system and developes a simulation model of DFIG by using PSCAD/EMTDC. In addition, this paper analyzes the steady state operation and the transient operation during the voltage sags in the power common coupling. The voltage sags are occurred by three phase line-to-ground faults and full-voltage startup of an induction motor in the simulation.

  • PDF

Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System (지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가)

  • Park, Si-Sam;Na, Sang-Min;Park, Jong-Hun;Rhee, Keon-Joong;Kim, Tae-Won;Kim, Sung-Yub
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

A Rise in Electric Potential of Telecommunication Line for Electric Power System by Lightning Surges (뇌서지에 의한 전력통신선로의 전위상승)

  • Lee, Bok-Hee;Chang, Sug-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1718-1720
    • /
    • 1997
  • This paper deals with n rise in electric potential of telecommunication line for electric power system by lightning surges. When $1.2/50{\mu}s$ and $8/20{\mu}s$ impulse voltage and current were applied on telecommunication cable, the voltage waveforms at the end terminal and equipment were measured. The telecommunication lines, which consist of 60 conductors and 3.5km in length, have some surge protectors such as preposition lightning arrester and TVSS. In each case, the rise in electric potential was measured for differential mode and common mode, respectively. Also, the rise in ground potential and the induced voltages were measured and analyzed. As a result, a significant rise in ground potential was observed for lightning surge. It can cause failure or malfunction of telecommunication systems.

  • PDF

A New PWM Method for Conducted EMI Reduction in Inverter fed Motor Drive System (인버터 구동 시스템에서의 EMI 저감을 위한 새로운 PWM 구현)

  • Kun Hahm Nyon;Kim Lee-Hun;Jun Ki-Young;Chun Kwang-Su;Won Chung-Yuen;Han Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.384-388
    • /
    • 2004
  • High frequency common mode voltage produced by power inverters are a major cause of conducted EMI, creating motor ground currents, bearing currents and other harmful by products. This paper focuses on a new SVPWM method with random PWM injection to reduce conducted EMI noise. A New PWM technique associated with the common mode voltage can be significantly reducing and contributes to mitigate. The common mode voltage to $50\%$ in comparison with that for conventional SVPWM technique. Validation of the theory and reduction methods are then performed experiment ally based on an induction motor drive.

  • PDF

International Time Comparisons in Common-View via Global Positioning System (GPS) Satekkutes (GPS위성 동시수신법에 의한 국제시각비교)

  • 이창복;전인덕;정낙삼
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.2
    • /
    • pp.81-87
    • /
    • 1990
  • International time comparisons using a commercial GPS receiver, with the common-view program of GPS satellite time links, have been carried out between Korea Standards Research Institute(KSRI) and Communications Research Laboratory(CRL) of Japan, and also between KSRI and United Stated Neval Observatory(USNO). The frequency stability is about 1.5 parts in $10^-13$ for the averaging time of 1day. The result of time comparisons obtained by the GPS common-view technique was about 10 times better than that by the LORAN-C(Long Range Navigation) ground wave technique.

  • PDF

Common Earth Network constitution for minimize surge damage (낙뢰 피해 최소화를 위한 공동 접지망 구성)

  • Kim, Yong-Kyu;Baek, Jong-Hyun;Choi, Kyoung-Il;Yoo, Keun-Su
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.190-195
    • /
    • 2008
  • Surge proof equipment is an installation to make surge flow on the ground promptly so as to reduce surge-related damage on infrastructure, not to prevent surge from falling down on infrastructure directly. Compared with classical line individual earth, High speed line common earth has higher surge characteristic and plays a significant role to prevent infrastructure damage and injuries from surge, or short circuit accident between 25kV catenary and rail. In this paper, we analyzed the case of accident that caused communication/signaling system impaired while a tractor crossing level crossing at Honam line; in addition, we examined the accident reduction measures to minimize injury and property damage from cutting accidents with respect to common earth network.

  • PDF