• Title/Summary/Keyword: Commercial Site

Search Result 459, Processing Time 0.045 seconds

Change of the Kyeong-seong-bu Administration Office's former Site after the Office's Moving out in 1926 -From a Administrative Center to a Commercial Center- (1926년 경성부청 이전 후 옛 청사 터의 변화 -행정 중심지에서 상업 중심지로 -)

  • Kim, Myungsun
    • Journal of architectural history
    • /
    • v.28 no.2
    • /
    • pp.19-30
    • /
    • 2019
  • The former administration office building of Kyeong-seong-bu(京城府) was a building converted from the Japanese residency-general's of Kyeong-seong(京城理事廳) which was originally built as the Japanese consulate in Joseon(日本領事館). It was too worn and too small as a Kyeong-seong-bu administration office even with several annexes. Kyeong-seong-bu tried to build a new big administration office building at the vacant north side of the same site, which was closely faced to the rotary in front of the Bank of Joseon(朝鮮銀行前廣場). But this trial was ended in vain due to insufficient budget. Therefore Kyeong-seong-bu built a new administration office building in another site and moved to it in 1926 with debts. For paying for the debts Kyeong-seong-bu sold the former site after partitioning with new roads through it. As a result the nature of the former site and its surroundings was changed. This study traces the changes and inquires how the authorities in the colonial Joseon and various commercial powers of Kyeong-seong-bu behaved for their own interests in the meantime. It makes use of the historical records and documentary literatures between early 1910s and early 1930s.

CSfC Network Security Architecture Analysis for the Assurance of Commercial Security Solutions in Defense Area (국방 상용보안제품 도입을 위한 CSfC(Commercial Solutions for Classified Program) 네트워크 보안 아키텍처 분석)

  • Lee, Yong-joon;Park, Se-joon;Park, Yeon-chool
    • Journal of Internet Computing and Services
    • /
    • v.22 no.6
    • /
    • pp.91-97
    • /
    • 2021
  • The United States is responding to evolving cyberattacks through the Commercial Solutions for Classified Program (CSfC). Authorized safety evaluation and certification are being carried out so that US government agencies can quickly introduce civilian commercial security products into the national pavilion. Commercial security products registered in the CSfC process can be used by defense agencies through a rapid approval process. Defense agencies approve commercial security products without duplicate evaluation. Approved security products can reduce the time, cost, and cost of the approval process required to implement the defense information system. In this study, security control for 4 types of network security architecture MSC (Multi-Site Connectivity), MA (Mobile Access), Campus WLAN, and DAR (Data at Rest) proposed by the US National Security Agency (NSA) for introduction to national defense A detailed analysis was performed on the items.

Functional Assessment of Frequency of a Commercial Shampoo for Normal Canine Skin (개에서 피부세정제 적용빈도가 정상피부에 미치는 영향)

  • Yu, Jong-Won;Shin, Hee-Ju;Bae, Seulgi;Choi, Sungwon;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.283-287
    • /
    • 2013
  • Canine skin is a highly dynamic organ that is constantly adapted to changes in its environment. It provides structural, sensory, immunologic, and physiologic functions and contributes an essential barrier function against potential environmental insults. We assessed the changes of canine skin hydration, pH, and protein contents by noninvasive method according to the frequency of application with canine commercial shampoo. Canine commercial shampoo was applied topically every other day, 5 days, and 8 days on different sites, respectively in 8 dogs. Saline-applied site was as a control. Skin hydration was increased and skin surface pH was decreased significantly in canine commercial shampoo-applied site every other day (p < 0.05). Also, skin protein concentration measured by D-squame$^{(R)}$ tape stripping method was increased significantly in canine commercial shampoo-applied site every other day (p < 0.05). There were alterations on every 5 days and 8 days, but not significantly. These results may be recognized that the frequent use of canine commercial shampoo cause abnormalities of the skin barrier function and alteration of stratum corneum integrity/cohesion. Consequently it was suggested that bathing the dog with canine commercial shampoo was appropriate every 5 or 8 days.

Comparison of local reaction at injection site following intramuscular administration with three commercial atrophic rhinitis vaccines in pigs

  • Kim, Myung-Hyee;Kwon, Taeyong;Yoo, Sung J.;Seo, Sang won;Park, Jun Woo;Lyoo, Young S.
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.4
    • /
    • pp.251-255
    • /
    • 2018
  • Bordetella bronchiseptica and Pasteurella multocida are two main pathogens responsible for atrophic rhinitis (AR), which causes considerable economic losses in swine industry worldwide. Commercial vaccine has been widely used to prevent the damage from AR in Korea. Adverse effects of vaccination at the injection site have been reported, which results in the numerous complaint from farms. However, data on about local reaction at the injection site remains limited. In this study, we compared the local adverse effects of three commercial vaccines following intramuscular injection. The results showed that no gross lesion was founded at the injection sites of all three vaccines. In histopathologic examination, a various level of lesions was identified. Especially, the local reaction of vaccine including saponin as an adjuvant showed the lowest level of histopathological lesions, when compared to those of oil-based and vitamin E-based vaccines. Therefore, this study would provide the information about the extent of local reaction at the injection site and help the farmer to select AR vaccine in order to avoid adverse reaction due to vaccination.

Calculation of preliminary site-specific DCGLs for nuclear power plant decommissioning using hybrid scenarios

  • Seo, Hyung-Woo;Sohn, Wook
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1098-1108
    • /
    • 2019
  • Korea's first commercial nuclear power plant at Kori site was permanently shut down in 2017 and is currently in transition stage. Preparatory activities for decommissioning such as historical site assessment, characterization, and dismantling design are being actively carried out for successful D&D (Dismantling and Decontamination) at Kori site. The ultimate goal of decommissioning will be to ensure the safety of workers and residents that may arise during the decommissioning of nuclear facilities and, thereby finally returning the site to its original status in accordance with the release criteria. Upon completion of decommissioning, the resident's safety at a site released will be assessed from the evaluation of dose caused by radionuclides expected to be present or detected at the site. Although the U.S. commercial nuclear power plants with decommissioning experience use different site release criteria, most of them are 0.25 mSv/y. In Korea, both the unrestricted and restricted release criteria have been set to 0.1 mSv/y by the Nuclear Safety and Security Commission. However, since the dose is difficult to measure, measurable concentration guideline levels for residual radionuclides that result in dose equivalent to the site release criteria should be derived. For this derivation, site reuse scenario, selection of potential radionuclides, and systematic methodology should be developed in planning stage of Kori site decommissioning. In this paper, for calculation of a preliminary site-specific Derived Concentration Guideline Levels (DCGLs) for the Nuclear Power Plant site, a novel approach has been developed which can fully reflect practical reuse plans of the Kori site by taking into account multiple site reuse scenarios sequentially, thereby striking a remarkable distinction with conventional approaches which considers only a single site scenario.

Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere (대기 중 TSP와 PM10 농도의 관련성)

  • 최진수;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

Characterization of PM10 and PM2.5 in Cheonan Area Using a Dust Monitor (Dust Monitor를 이용한 천안시 대기 중 PM10, PM2.5 오염특성 조사)

  • Lee, Hyun-Mi;Oh, Se-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.367-375
    • /
    • 2008
  • To characterize atmospheric particles in Cheonan area, 5 monitoring sites representing highway area, commercial area, residential area, and industrial areas were selected, and the mass concentrations of PM10 and PM2.5 were monitored for 14 days at each site during 2007. The daily average PM10 and PM2.5 concentrations were in the range from 18.5 to $140.9{\mu}g/m^3$ and 8.2 to $116.6{\mu}g/m^3$, respectively, showing the highest mean concentrations at the commercial area site and the lowest concentration at the residential area site. The daily average PM 10 concentrations at Shinan (Commercial area) and Bakseok (Industrial area) sites were exceeded the current National Standard for 1 and 2 days during the monitoring periods. The fractions of PM2.5 in PM10 were above 70% for all sites, indicating fine particles are the major constituent of atmospheric particles in Cheonan. The results indicate that PM10 concentrations in Cheonan are at the concerning level, and the control strategy for fine particles is necessary to address this issue.

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea (II) - Seasonal and Locational Variations (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(II) -계절 및 지역적 변동)

  • 백성옥;김배갑;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.207-217
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the second part of the study, the seasonal and locational concentrations of atmospheric VOCs were evaluated. Sampling was conducted seasonally at seven sampling sites. each of them representing a large urban area (commercial and residential), a small urban area (commercial and residential), an industrial area (a site within the complex and a residential), and a background place in Korea. In general, higher concentrations were found in the petro-chemical industrial site than other sites, while VOCs measured in commercial (heavy -traffic) sites were higher than residential sites. Seasonality of VOCs concentrations were not so much clear as other combustion related pollutants such as sulfur dioxide, indicating that the VOCs are emitted from a variety of sources, not only vehicle exhaust and point sources but fugitive emissions. Except the industrial site, the concentrations of VOCs measured in this study do not reveal any serious pollution status, since the levels did not exceed any existing ambient standards in the U.K. and/or Japan. However, the increasing number of petrol -powered vehicles and the rapid industrialization in Korea may result in the increased levels of VOCs concentrations in many large urban areas in the near future, if there is no appropriate programme implemented for the control of these compounds.

Analysis of accidents due to Urban Ground Excavation (지반굴착공사로 인한 사고사례 분석)

  • Seong, Joo-Hyun;Yoon, Jong-Ku;Jung, Soo-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1087-1094
    • /
    • 2010
  • With recent growth of population and industry, urban development grows into grand scheme of excavation and construction in urban area. As the development progress advanced, the developments get large and deepen. With a progress of technology development in geotechnical engineering in Korea, most our grand scheme of projects follows great progress. On the other hand, some excavation in construction site caused direct or indirect event that affects the adjacent or surrounding structures by excavation from time to time. This event usually happens around residential and commercial area where underground tunnel, subway station, commercial building, and high-rises excavation site is, could lead great damage on economy as well as personal injury or human casualties. In order to prevent this event, the study has to be done with analysis on various events of excavation and its cause. In this paper, the research has collected the various excavation events and their causes to analyze on each site and event to define emphasis on surrounding environment.

  • PDF

Design of a Biconical Antenna with Cylindrical Loads for EMI Test Site Validation above 1 GHz

  • Kong, Sung-Sik;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, a biconical type antenna is proposed for EMI test site validation above 1 GHz. To achieve broadband and omni-directional radiation patterns required by international standard(CISPR), the proposed antenna consists of general bicones with cylindrical loads and adopts side feeding method to minimize the influence on H-plane pattern due to feeding cable, balun, and connector. The radiation patterns of the fabricated antenna are measured and the results are compared with CISPR criteria and commercial antenna in our interest frequencies. Although the proposed antenna has a few problems in frequency range of 1 GHz to 2 GHz, it has relatively better performance than commercial antenna.