• Title/Summary/Keyword: Commercial Fire

Search Result 176, Processing Time 0.025 seconds

A Study on the Fire Scenarios according to Initial Fire Source Classification and Fire Statistics Investigation of Business & Sales Faciliteis (업무·판매시설의 화재통계조사 및 초기화원분류를 통한 화재시나리오에 관한 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.42-43
    • /
    • 2017
  • In Korea, The buildings are getting higher and bigger, and also the fire risk is getting increased. The PBD was introduced in 2009 for the fire safety of these buildings, but the study on making scenario based on actual case of fire is insufficient. Therefore on this study, it will conduct an experiment about initial fire classification and making fire scenario based on that actual fire statistic investigation classification of PBD buildings as official and commercial facilities.

  • PDF

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

A Study on the Proposal of Durability and Service Life of Fire Door in apartment house (공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구)

  • Kwon, Yeong-Jin;Kim, Yun-Seong;Jin, Seung-Hyeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

Development of a Low-Cost Thermal Image Hidden Fire Detector Using Open Source Hardware (오픈소스 하드웨어를 사용한 저비용 열화상 잔불탐지 장치 개발)

  • Moon, Sangook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1742-1745
    • /
    • 2019
  • Hidden flame detection after allegedly extinguishing a fire cannot be emphasized enough. There are a few commercial hidden fire detection equipments which are imported, but the cost is relatively high. In this contribution, we propose a development of a low-cost, high-performance hidden flame detector using open-source hardware/software. We use Raspberry-pi based hardware board equipped with a TFT touch-screen LCD, a 3G modem, and an attachable battery device altogether integrated in a plastic case fabricated with a 3D printer. The proposed hidden flame detector shows the same performance of a commercial product FLIR E5 while consuming less than a half of the cost.

A Study on the Fire-Safety and Escape plan of Hotel Design (호텔건축의 화재안전과 피난계획에 관한 연구)

  • 김기만;박윤성
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 1988
  • Due to its commercial, ceremonial function, the hotel design has a tendency to be higher and larger, and its form being varied. But this tendency is not desirable in respect of architectural fire-safety. The higher its height and the larger its mass becomes, relatively the damage expectation becomes. Moreover, in case of fire, it is expected that many serious problems break out, because the users of a hotel, unlike those of office building or housing, are majority of unspecified people and they have no information about that building. Therefore, this study dealt with fire-safety problem in hotel design and tried to find out countermeasures of fire-safety and successful escafe against fire.

  • PDF

Trend of Fire Outbreaks in Ghana and Ways to Prevent These Incidents

  • Addai, Emmanuel K.;Tulashie, Samuel K.;Annan, Joe-Steve;Yeboah, Isaac
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Background: In Ghana, fire incidents have become a regular occurrence, with thousands of lives and millions of dollars lost every year. Hardly a day passes without news of a fire outbreak in some part of Ghana, causing fear and panic among the people. This generates much discussion centering on rumors relating to politics, sabotage, misfortune, religious differences, etc. This article seeks to discuss the trend of fire incidents occurring in Ghana from 2000 to 2013 and the different ways to prevent these incidents. Methods: The pattern of fire incidence in Ghana as a whole as well as in each region is discussed. The study took into consideration the causes, mechanisms, as well as preventive measures against the fire menace. Data were obtained from the head office of Ghana's national fire service. Results: It was noticed that in general the rate of fire incidence increased each year. This increase was attributed to several factors: rate of population growth and industrialization, unstable electricity, urbanization, negligence, illegal electrical connection, etc. The cause of fire was categorized into domestic, industrial, vehicular, institutional, electrical, commercial, bush, and others. Among these causes, domestic fire accounted for 41% of the total number of fire incidents in the country. Conclusion: Finally, this study presents several recommendations to help prevent and mitigate fire incidents in Ghana.

A Fire Computer Simulation of Inner Space with Fire Shutters and Refuge Stairs (방화셔터와 피난계단이 존재하는 실내 환경의 화재 컴퓨터 시뮬레이션)

  • Yoo, Doo-Yul;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1617-1624
    • /
    • 2013
  • This paper analyzes the relation between fire shutters and fire spread by conducting fire simulation on inner space with fire shutters. Using Fire Dynamics Simulator (FDS), a commercial fire simulation software, the simulation is done on an ideal inner robby, where fire size and the open/close of fire shutters are varied. Our simulation environment can derive significant fire parameters such as temperature variation of fire room walls and entrances of refuge stairs, variation of carbon dioxide, and soot spread. According to the simulation results, temperature and carbon dioxide distribution in refuge stairs have little dependence on vent open or close, but the part close of fire shutters blocks soot inflow to refuge stairs.

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.

Formulation of Fire Reliability Assessment Method for Structural Strength (화재 구조강도에 대한 신뢰성 평가방법의 정립)

  • 양영순;유원선;이상엽
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.161-168
    • /
    • 2004
  • This study describes the behavior and failure probability of basic structural member in case of fire for the research of safety assessment on onshore structure. Fire safety assessment can be done by comparing fire resistance of members with fire severity of heat load For more Practical applications, the commercial structural analysis program is linked with the in-house code and gets the limiting temperature by analyzing structural strength of member with elasto-plastic analysis and large deflection analysis. AFOSM method is utilized to obtain the failure probability against the fire. The examples of rather simple structures such as beams and plates are applied to explain and verify the procedure of fire safety assessment.

  • PDF

Fire Performance Analysis of SLIM AU Composite Beam (슬림 AU 합성보의 내화해석)

  • Kim, Myeong-Han;Oh, Myoung-Ho;Min, Jeong-Ki
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.133-140
    • /
    • 2016
  • SLIM AU(A plus U-shaped) composite beam had been developed for not only reducing the story height in residential and commercial building, but also saving the cost of floor construction. The structural performance and economic feasibility was sufficiently approved by means of structural experiments and analytical studies. Even though fire resistance of the SLIM AU composite beam was evaluated throughout furnace fire test, the fire performance of the composite beam using finite element analysis is not analysed yet. Therefore the predictions of fire resistance simulations with loading as well as temperature distribution of the composite beam are summarized in this paper.