• 제목/요약/키워드: Commercial Facilities

검색결과 553건 처리시간 0.03초

A Study on Furniture Design Using By-product of Wood Furniture (목재가구 부산물(副産物)을 활용한 가구디자인 연구)

  • Jung, Jaenah;Yoon, Yeoh-hang
    • Journal of the Korea Furniture Society
    • /
    • 제27권1호
    • /
    • pp.15-25
    • /
    • 2016
  • Increasing concerns of environment need to make change furniture field to more environmentally friendly approach, such as reuse of by-products from wooden products. As it is, the methods of recycling wood for industrial purposes have the advantage of productivity and adaptability. However, the industrial way is required a certain production facility of processing wooden by-products and has possible hygienic problems due to contaminated sources. Many designers have developed their own methods for reuse of wood in unique and artistic ways. Even so, because of confined sources, it could be not enough supply. Therefore, I developed the design methodology utilizing wooden by-products from S Design Company to relieve former ways' problems. The design suggestion took materials from a safe and abundant source. The wooden leftover pieces were connected together with epoxy clay, so previous process traces of furniture are remained as a decorative factor. Moreover, the synthesized material was able to be processed by ordinary woodworking facilities without additional installations. In doing so, console table focused on a commercial purpose and dining table for an artistic objective were successfully fabricated as final suggestions. In consideration of the proposal using wooden furniture leftovers, diverse recycling designs should be investigated for future reference.

A Case Study of Oversea's Low Cost Carrier Terminal (LCCT) for Hub Network Competitiveness (허브경쟁력 강화를 위한 해외 저가항공사 터미널(LCCT) 활용 사례연구)

  • Hwang, Sung-Youn;Kim, Jong-Hyun;Park, Sung-Sik;Kim, Kee-Woong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • 제22권4호
    • /
    • pp.15-24
    • /
    • 2014
  • Low Cost Carrier(LCC)s in Asia Pacific market are expected to record high growth due to the expansion of Open Sky Policy among Korea, Japan, China and South East Asia. As everybody is aware of, LCC is not only saving flight cost but also creates differentiating business model by reducing unnecessary services such as F&B and in-flight duty free sales services. Booming LCCs in Asian market will cause not only Incheon airport but also other local airports in Korea to compete heavily to attract LCCs. For example, Air Asia Group with more than 200 fleet has expanded its alliance network throughout Asia. Therefore this paper has researched a new business model operating a LCC terminal for the hub airport competitiveness. According to analysis result of case study, it was found out, considering increasing airline demand next decade, Incheon airport and other domestic airports in Korea had better change an existing terminal into a LCC Terminal(LCCT) to differentiate airport services and expand its hub network. That is because of economic feasibility, first of all, of securing hub and spoke networking capabilities with airlines and finally of developing commercial facilities customizing LCC passengers' demand.

A Study of Commercial Rental Properties within a Large Complex Facility by Measuring the Spatial Structure (공간 구조와 보행량 측정을 통한 대형 복합시설물 상가 임대료 특성에 관한 연구)

  • Hwang, Jae-Hong;Ahn, Byung-Ju;Kim, Ju-Hyung;Kim, Jae-Joon
    • Journal of the Korea Institute of Building Construction
    • /
    • 제10권6호
    • /
    • pp.87-96
    • /
    • 2010
  • This research analyzed the location of stores using a space syntax analysis model to measure the location of building interior stores in a quantitative way. Measure walk population of each space and analyzed analysis model and actuality measurement rent and difference to calculate value of store. With this, analyzed mad effect factor to rent. Drew effect factor of rent which is appropriated present. Had cleared that rent which consider walk population is required.

A Study on Snow Melting System for the Anti-freezing Testing Road (시험선로 결빙방지를 위한 융설시스템에 관한 연구)

  • Han, K.I.;Lee, A.H.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • 제10권1호
    • /
    • pp.34-40
    • /
    • 2006
  • The snow melting system by electric heating wires which is adopted in this study is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow accumulated on it. The system is designed to increase traffic safety and capacity. The electric heating wires are buried under paved road at a certain depth and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, and installation place where the system applies. It is tried to figure out that the appropriate range of required heat capacity and installation depth and intervals for solving snowdrifts and freezing problems with the minimum electric power consumption. The most important factors to design the system are calculation of heating capacity depending on weather condition and depth and interval of the electric heating wires depending on air condition respectively. The study were performed under the range of the air temperatures($-2^{\circ}C,\;-5^{\circ}C,\;-8^{\circ}C$), the intervals of the electric heating wires(70mm, 100mm, 125mm), and the installation depths(50mm, 70mm, 100mm). The ready made commercial program package was used to verify the experimental results.

  • PDF

Estimation of the Noise Caused by the System Air Conditioner and its Improvement (시스템 에어컨에 의한 실내 소음 평가 및 개선 설계)

  • Lee, Jea-Won;Joo, Jae-Man;Oh, Sang-Kyong;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF

A Noise Prediction of Floating, Production, Storage and Offloading(FPSO) (부유식 석유생산.저장.하역선박의 소음해석)

  • Kim, Young-Hyun;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF

A new design concept for ocean nuclear power plants using tension leg platform

  • Lee, Chaemin;Kim, Jaemin;Cho, Seongpil
    • Structural Engineering and Mechanics
    • /
    • 제76권3호
    • /
    • pp.367-378
    • /
    • 2020
  • This paper presents a new design concept for ocean nuclear power plants (ONPPs) using a tension leg platform (TLP). The system-integrated modular advanced reactor, which is one of the successful small modular reactors, is mounted for demonstration. The authors define the design requirements and parameters, modularize and rearrange the nuclear and other facilities, and propose a new total general arrangement. The most fundamental level of design results for the platform and tendon system are provided, and the construction procedure and safety features are discussed. The integrated passive safety system developed for the gravity based structure-type ONPP is also available in the TLP-type ONPP with minor modifications. The safety system fully utilizes the benefits of the ocean environment, and enhances the safety features of the proposed concept. For the verification of the design concept, hydrodynamic analyses are performed using the commercial software ANSYS AQWA with the Pierson-Moskowitz and JONSWAP wave spectra that represent various ocean environments and the results are discussed.

Use of Ionizing Radiation as a Phytosanitary Treatment for Postharvest Disease Control

  • Jeong, Rae-Dong
    • Journal of Radiation Industry
    • /
    • 제8권2호
    • /
    • pp.97-104
    • /
    • 2014
  • Postharvest diseases cause considerable losses to harvested fruits and vegetables worldwide. Fresh produce suspected of harboring postharvest disease must be treated to control any pathogens present. Although there are various treatments to control postharvest losses by pathogens, the current community is eager to take safer and more eco-friendly alternatives to help with human health and reduce environmental risks. Ionizing irradiation is a promising phytosanitary treatment that has a significant potential to control postharvest diseases in use worldwide. Although almost 19000 metric tons of sweet potatoes and various fruits are irradiated each year in six countries to control postharvest disease, irradiation continues to be a debate, with slow acceptance by industries. Irradiation alone is not effective as a fungicide, and an over dose affects the physical properties of irradiated products. A combination of irradiation with other treatments such as heating, biocontrol agents, chlorination, and nano Ag particles is to enhance their effectiveness. Challenges to the use of phytosanitary irradiation are an avoidance of irradiated postharvest and cost of the irradiation facilities, and thus consumers still need to be educated on the principles and benefits of irradiation and prepare an optimum economy of scale for commercial use. In this review, we evaluated the current phytosanitary irradiation, and combination with various other treatments to minimize the postharvest losses.

Structural Design and Construction of High-rise Building to Feature the High-performance Oil Dampers for Vibration Control - Hibiya Mitsui Tower -

  • Kato, Takashi;Hara, Kenji;Tanaka, Hiroyuki
    • International Journal of High-Rise Buildings
    • /
    • 제8권3호
    • /
    • pp.229-234
    • /
    • 2019
  • This report introduces the structural design of Hibiya Mitsui Tower built in Tokyo Midtown Hibiya. The upper part of this tower is used for offices and the lower portion is for commercial facilities and a cinema complex which need the large open spaces. The 192m-high building has 35 floors above ground and 4 below ground. The structure is a steel frame using CFT columns to feature the high-performance oil dampers and the buckling restrained braces for vibration control. First, an outline of the structural design of this building is presented. Second, we introduce the transfer frame adopted to realize the large open spaces in the lower part, and the long column supporting the corner part of the high-rise building to avoid making a shade on the adjacent Hibiya Park, which are the feature of this building. Finally, we present an outline of the latest highly efficient semi-active oil dampers adopted in this building, and the vibration responses of this tower.

A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway (전철 지중배전선로의 충전전류보상에 관한 연구)

  • Kim, Yang-Su;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF