• Title/Summary/Keyword: Combined system

Search Result 5,713, Processing Time 0.028 seconds

Realtime Monitoring system of Residential Photovoltaic system (태양광-풍력 복합발전시스템의 출력제어 특성에 관한 연구)

  • Lee J.I.;Suh J.S.;Yoon P.H.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.933-937
    • /
    • 2003
  • The development of the solar and the wind power energy are necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic(400w) and wind power generation system(400w) was suggested. It combines wind power and solar energy to have the supporting effect from each other However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator

  • PDF

A Formulation Study on the Combined Preparation of Nitroxynil and Levamisole for Subcutaneous Injection (Nitroxynil과 Levamisole의 피하 주사용 복합제제의 설계에 관한 연구)

  • Oh, Soon-Gyun;Oh, Kyoung-Hee;Kim, Chong-Kook
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 1994
  • In order to develop a broad-spectrum veterinary anthelmintic, a combined preparation of nitroxynil and levamisole was formulated for subcutaneous injection. The preformulation studies on solubilization, physicochemical stability and toxicity of combined preparation were performed. The combined preparation of nitroxynil-N-ethylglucamine and levamisole base could be solubilized up to 50.3%(w/v) of active ingredient concentration in propylene glycol/water system. Injectable solutions were most stable at $4^{\circ}C$. Local toxicities such as flare and edema were not shown when the usual dose of the combined preparation was injected subcutaneously to the rats.

  • PDF

Extracting parameters of TMD and primary structure from the combined system responses

  • Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • v.16 no.5
    • /
    • pp.937-960
    • /
    • 2015
  • Tuned mass dampers (TMDs) have been a prevalent vibration control device for suppressing excessive vibration because of environmental loadings in contemporary tall buildings since the mid-1970s. A TMD must be tuned to the natural frequency of the primary structure to be effective. In practice, a TMD may be assembled in situ, simultaneously with the building construction. In such a situation, the respective dynamic properties of the TMD device and building cannot be identified to determine the tuning status of the TMD. For this purpose, a methodology was developed to obtain the parameters of the TMD and primary building on the basis of the eigenparameters of any two complex modes of the combined building-TMD system. The theory was derived in state-space to characterize the nonclassical damping feature of the system, and combined with a system identification technique to obtain the system eigenparameters using the acceleration measurements. The proposed procedure was first demonstrated using a numerical verification and then applied to real, experimental data of a large-scale building-TMD system. The results showed that the procedure is capable of identifying the respective parameters of the TMD and primary structure and is applicable in real implementations by using only the acceleration response measurements of the TMD and its located floor.

Efficiency of Combined Action of Moxalactam and Fosfomycin Determined by MS-2 System Against Penicillin-resistant Staphylococcus aureus Isolates (MS-2 system을 이용한 황색포도구균에 대한 moxalactam과 fosfomycin의 병용효과 측정)

  • Park, Chan-Sok;Ahn, Tai-Hew
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.3
    • /
    • pp.381-385
    • /
    • 1986
  • Twenty strains of penicillin(PC)-resistant Staphylococcus aureus ($MIC{\geqq}32U/ml$) were chosen randomly from recent isolates and submitted to the present experiment to see what effect the combined antibiotic action of moxalactam(MX) and fosfomycin(FM) would bring about on the cells, using MS-2 system. 1. The conventional agar dilution method and the rapid automatic MS-2 system were used in measuring the MICs of MX and FM against each strain and the comparison of the data obtained revealed no significant difference between the two methods in the titer and distribution of the MICs. 2. The automatic MS-2 system was, therefore, used alone in determining the combined growth inhibitory effect of MX and FM because of its more rapidness, and the obtained results were that most of the PC-resistant strains(16 out of 20, 80%) were synergistically inhibited by the two antibiotic combination while additive effect was observed in the remaining 4 strains(20%). 3. Thus, it is suggested that the growth of PC-resistant staphylococcal cells may be synergistically inhibited by MX and FM combination and the efficiency of two antibiotic action as well as MIC of single antibiotic may be more rapidly determined by the MS-2 system than by the conventional method.

  • PDF

A Study on the Discontinuous Energy Ceneration System for Power Compensation (불연속 에너지 발생장치의 에너지 보상 시스템에 대한 연구)

  • Lee, Jeong-Il;Lim, Jung-Yeol;Kang, Byung-Bog;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.133-138
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

  • PDF

Design and Implementation of Combined RF Receiver Front End for GPS/GLONASS (GPS/ GLONASS 통합 수신용 RF 전단부의 설계 및 제작)

  • 주재순;염경환;이상정
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.494-502
    • /
    • 2001
  • GPS(Global Positioning System) and GLONASS(GLObal Navigation Satellite System) are basic technologies providing the information of the position and the time, and they have various applications such as navigation, survey, control, and so on. However, each GPS and GLONASS has limited number of visible satellites, and, from the view of strategy, it is undesirable to be heavily dependent on only one system. Thus, GPS/GLONASS combined receiver became required to obtain more precise navigation and system stability. In this paper, the RF front end of GPS/GLONASS combined receiver was fabricated on 130$\times$80 $\textrm{mm}^2$ PCB(Printed Circuit Board), and its system application was shown finally one chip possibility of GLONASS receiver is studied.

  • PDF

Dynamic Equivalents Program combined with Graphic Environments (그래픽환경을 갖춘 동태등가프로그램)

  • 임성정;윤용한;김재철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.32-36
    • /
    • 1992
  • This paper develops the dynamic equivalents program combined with graphic user interface(GUI), to solve the stability of large power system. The p개posed method is coherency-based dynamic equivalents for transient stability studies. The program also provides with pull-down menu and Hangout help information for users. The developed dynamic equivalents program is suitable for the transient stability studies of a large power system with lots of data. The dynamic equivalents demonstrated over the New England system with 39 buses and 10 generators.

  • PDF

Operating Characteristics Study of a Small Gas/Steam Turbine Combined System Using Biogas (바이오가스 연료를 사용하는 소형 가스/증기터빈 복합 발전 시스템의 성능특성 해석)

  • Kang, Do-Won;Shin, Hyun-Dong;Kim, Tong-Seop;Hur, Kwang-Beom;Park, Jung-Keuk
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2012
  • This study analyzed the influence of firing biogas on the performance and operation of a gas/steam turbine combined system. A reference gas/steam turbine combined system, designed with biogas fuel(57% volumetric methane) was set up and off-design simulation was made to investigate operating characteristics when a couple of operating schemes to mitigate turbine blade overheating were applied. Performance at base-load operation using each scheme was compared and part load operation using the variable inlet guide vane was analysed. Also, differences in operating characteristics and performance caused by changes in the methane content of biogas and ambient temperature were examined.

Performance Design Analysis of the Bottoming System of Combined Cycle Power Plants (복합화력발전 하부시스템의 성능설계해석)

  • Lee, B.R.;Kim, T.S.;Ro, S.T.;Shin, H.T.;Jeon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.738-743
    • /
    • 2001
  • A computer program, capable of performing thermal design analysis of the triple pressure bottoming system of combined cycle power plants, was developed. The program is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. The program is applicable to various parametric analyses including optimized design calculation. This paper presents examples of analysis results for the effects of arrangement of heat exchanger units, steam pressures and deaerating sources on design performance indices such as steam turbine power and the size of heat recovery steam generator.

  • PDF

Hydration in the System of Fluorogypsum-Blast Furnace Slag (불산석고-고로슬래그계의 수화반응)

  • 송종택;고상열;노재성
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.9
    • /
    • pp.933-938
    • /
    • 1998
  • The hydration for the system of fluorogypsum and 20wt% blast furnace slag was investigated at liquid/soild ratio of 0.45 for 1, 3, and 7 days by using 3 kinds of accelerators such as K2SO4 Al2(SO4)3 $.$16-18H2O and AlK(SO4)2$.$12H2O After curing the hardened specimen was characterized by the compressive strength the content of combined water XRD, DTA and SEM It was found that the activating effect was increased in the order of K2SO4

  • PDF