• 제목/요약/키워드: Combined deterioration environments

검색결과 10건 처리시간 0.027초

복합열화 환경하에서 표면피복종류 및 피복두께에 따른 철근콘크리트의 부식특성 (Corrosion Properties of Reinforced Concrete with Types of Surface Cover and Covering Depth under the Combined Deterioration Environments)

  • 김무한;권영진;김용로;김재환;장종호;조봉석
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.119-126
    • /
    • 2004
  • Generally, reinforced concrete is one of the most commonly used structural materials and it prevents corrosion of steel bar by high pH of interior, But, as time elapsed, reinforced concrete structure become deteriorated by many of combined deterioration factors and environmental conditions. And, there are large number of deteriorate mechanism of the reinforced concrete structure and it acts complexly. It is recognized that steel bar corrosion is the main distress behind the present concern regarding concrete durability. In this study, to institute combined deterioration environments, established acceleration condition and cycle for combined deterioration environments has a resemblance to environments which are real structures placed. After that to confirm corrosion properties of reinforced concrete due to permeability with covering depth and types of surface cover under combined deterioration environments, measured carbonation velocity coefficients, chloride ion diffusion coefficients, water absorption coefficients, air permeability coefficients and electric potential, corrosion area ratio, weight reduction, corrosion velocity of steel bar. The results showed that an increase in age also decrease carbonation velocity coefficients, increase Chloride ion diffusion coefficients and increases water absorption coefficients. As well, an increase in age also increases corrosion of steel bar. Data on the development of corrosion velocity of steel bar with types of surface cover made with none, organic B, organic A, inorganic B, and inorganic A is shown. As well, permeability and corrosion velocity of steel bar with covering depth is superior to 10mm than 20mm. And it is confirmed permeability and corrosion properties of steel bar are closely related.

혹독한 환경에서의 무근콘크리트 복합열화 저감을 위한 배합설계 및 품질관리 방안 구축 (Building mix design and quality control measures to reduce the combined deterioration of plain concrete in harsh environments)

  • 김대건;박찬규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2016
  • Recently damages caused by the additional costs and degradation in durability combined deterioration due to plain concrete deterioration has occurred. In particular, in the case of the finish that is not exposed to the outside air in the concrete to respond to the harsh environment (freeze-thawing, calcium laying, etc.), to establish a quality control way for the process and the concrete mix design for it.

  • PDF

콘크리트 구조물의 단일 및 복합열화 환경하에서의 염소이온 확산특성 (Diffusion Characteristics of Chloride ion under Single and Combined Attacks in Concrete Structures)

  • 오병환;강의영;인광진;이성규;서정문
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.708-717
    • /
    • 2002
  • 해안 등 열악한 환경에 노출되는 구조물들의 건설이 증가되면서 구조물의 내구성 문제가 심각해지고 있다. 특히, 염해만이 아니라 염해와 황산염 그리고 중성화 등 복합작용에 의한 열화문제는 아직도 연구된 바가 거의 없는 실정이다. 따라서, 본 연구에서는 염해와 황산염 및 중성화가 복합된 환경하에서 콘크리트 구조물의 성능저하 현상을 살피고 이들의 상호작용과 영향을 실험적으로 구명하는데 그 목적을 두고 있다. 이를 위해서 단일 및 복합열화 실험을 포괄적으로 수행하였다. 본 연구결과, 염소이온 단일열화시 보다 황산염 또는 황산염과 중성화가 복합되었을 경우의 열화현상이 더 두드러졌으며, 모든 열화조건에서 표면염소이온의 농도는 시간에 따라 증가하고 반면에 확산계수는 시간에 따라 감소하는 경향을 나타냈다. 표면염소이온 농도는 복합열화에서 더 증가하며 특히 염소이온 확산계수는 염해와 황산염 2중 복합열화시 더 커지고 여기에 중성화가 복합될 경우 더욱 커지는 것으로 나타났다. 따라서, 해안 구조물과 같이 염해와 황산염 및 중성화가 복합될 경우 염소이온의 침투가 더욱 커져 이들의 합리적인 고려가 필요한 것으로 나타났다.

Degradation mechanisms of concrete subjected to combined environmental and mechanical actions: a review and perspective

  • Ye, Hailong;Jin, Nanguo
    • Computers and Concrete
    • /
    • 제23권2호
    • /
    • pp.107-119
    • /
    • 2019
  • In-service reinforced concrete structures are simultaneously subjected to a combination of multi-deterioration environmental actions and mechanical loads. The combination of two or more deteriorative actions in environments can potentially accelerate the degradation and aging of concrete materials and structures. This paper reviews the coupling and synergistic mechanisms among various deteriorative driving forces (e.g. chloride salts- and carbonation-induced reinforcement corrosion, cyclic freeze-thaw action, alkali-silica reaction, and sulfate attack). In addition, the effects of mechanical loads on detrimental environmental factors are discussed, focusing on the transport properties and damage evolution in concrete. Recommendations for advancing current testing methods and predictive modeling on assessing the long-term durability of concrete with consideration of the coupling effects are provided.

산업체 VOC/악취 저감기술 (Removal Technologies of Odor and Volatile Organic Compounds from Industrial Processes)

  • 추수태;남창모
    • 한국산업융합학회 논문집
    • /
    • 제7권3호
    • /
    • pp.289-297
    • /
    • 2004
  • Emissions of volatile organic compounds and odors from various industrial processes not only pollute surrounding life environments, but also lead to the deterioration of the working environments, causing various industrial health and business problems. These pollutants are usually stimulating, irritating, malodorous and sometimes carcinogenic, Which should be reduced in the pollutants formation, stage, but the practical processes do not allow This paper describes the major sources of VOC and odors, and their sampling/analysis methods. Furthermore, various removal technologies for these pollutants are suggested, which particularly include the characteristics of the catalytic and scrubber/carbon filter combined process, and even process design technologies.

  • PDF

염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구 (Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts)

  • 박상순;이민우
    • Corrosion Science and Technology
    • /
    • 제13권6호
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.

A Numerical Model for the Freeze-Thaw Damages in Concrete Structures

  • Cho Tae-Jun
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.857-868
    • /
    • 2005
  • This paper deals with the accumulated damage in concrete structures due to the cyclic freeze-thaw as an environmental load. The cyclic ice body nucleation and growth processes in porous systems are affected by the thermo-physical and mass transport properties, and gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and diffusion of chloride ion effects are hard to be identified in tests, and there has been no analytic model for the combined degradations. The main objective is to determine the driving force and evaluate the reduced strength and stiffness by freeze-thaw. For the development of computational model of those coupled deterioration, micro-pore structure characterization, pore pressure based on the thermodynamic equilibrium, time and temperature dependent super-cooling with or without deicing salts, nonlinear-fracture constitutive relation for the evaluation of internal damage, and the effect of entrained air pores (EA) has been modeled numerically. As a result, the amount of ice volume with temperature dependent surface tensions, freezing pressure and resulting deformations, and cycle and temperature dependent pore volume has been calculated and compared with available test results. The developed computational program can be combined with DuCOM, which can calculate the early aged strength, heat of hydration, micro-pore volume, shrinkage, transportation of free water in concrete. Therefore, the developed model can be applied to evaluate those various practical degradation cases as well.

커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구 (A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall)

  • 장필성;홍순구;김성래
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.279-287
    • /
    • 2018
  • 실란트는 현대 건축물의 중요한 요소로 사용되고 있으며, 습기, 공기, 기타 물질의 침입에 대한 방벽을 제공함으로서 내후성에 대한 건물 보호의 역할을 한다. 다양한 환경에 노출되어 물리적, 화학적, 기계적 특성이 변화되어 수명이 단축되는 경우가 많으며, UV, 습기, 온도 신축 등은 내구성과 직결되는 중요한 이슈이다. 본 연구에서는 구조용 실링마감재의 내구성능을 실내에서 검증하기 위한 장비로서 외기의 환경을 모사할 수 있는 복합열화시험 챔버를 제작하였다. 황사, 산성비, 미생물에 의한 오염 등 특이 기상 상황의 재현은 어려우며 외기 환경을 100 % 모사하는 것은 불가능한 것으로 판단되며, 구조용 실링재의 옥외폭로시험방법과 복합열화시험장치에 대한 내후성 시험 결과 간의 상관관계를 통해 재현성을 확보하고자 연구하였다. 옥외폭로시험의 변위량 시험 결과 실링재의 응집력이 분해되어 연질화가 진행되는 것으로 판단되었고, 옥외폭로 1년 후 변위는 초기 물성치보다 3600 Pa에서 3배 정도 차이가 나는것을 볼 수 있었고, 비교제품의 경우 최대 7배까지 변위가 차이나는 것으로 확인되었다. 복합열화시험장치에서 변위시험결과 열화되어 탄성 및 인장특성이 감소하는 경향을 나타내었다. 변성실리콘 실링재의 경우는 현재 400 Cycle을 완료하여 옥외폭로 12개월의 물성저하를 확인하였다. 시험체의 변형은 육안으로는 확인할 수 없어 상대적으로 실리콘 실링재 제품보다 상태 안정성이 양호한 것으로 판단된다. 옥외폭로시험 결과, 복합열화시험장치가 체계화되어 관련 지침 또는 규격 등에 제안된다면, 실제 사용환경에서 12개월의 예상수명을 실내에서 3개월 미만에서 검증할 수 있는 방법으로 향후, 경제적 손실저감, 공기단축, 설계에 예상 가능한 재료의 선정 등에 활용될 것으로 기대된다.

탄산화 작용에 따른 콘크리트의 세공구조 성상에 관한 실험적 연구 (An Experimental Study on the Pore Structure Property of Concrete by Carbonation)

  • 김영봉;김영선;이의배;나철성;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.537-540
    • /
    • 2008
  • RC 구조물은 반영구적인 재료로 인식되어 왔으나, 최근 RC 구조물의 조기 열화에 의한 문제가 보고되고 있다. 이중 내구성능 저하 요인으로서 탄산화에 의한 공극구조의 변화로 인하여 발생하는 문제에 대한 연구가 필요한 실정이다. 따라서 본 연구에서는 물-결합재비율을 0.55로 고정하고 결합재로서 보통포틀랜드 시멘트만을 사용한 (OPC), 이성분계 콘크리트로서 결합재에 고로슬래그 미분말을 50% 치환한 (BFS50), 플라이애시를 15% 치환한 (FA15), 또한 삼성분계 콘크리트로서 플라이애시 15% 및 고로슬래그 미분말을 35% 치환한 (BFS35+FA15)로 배합을 설정하였다. 또한 탄산화에 진행에 의한 공극구조의 변화로 열화요인의 작용으로 인한 $CO_2$ 및 염화물 이온의 침투 특성을 단독열화 시험과 복합열화 시험을 통해 비교 연구하여 평가를 실시하였다. 그 결과 공극구조의 변화에 따른 영향으로 인하여 염화물 이온의 침투속도가 영향을 받는 것으로 나타났다.

  • PDF

탄산화 복합환경시 염소이온 확산에 관한 연구 (Influence of Carbonation for Chloride Diffusion in Concrete)

  • 오병환;이성규;이명규;정상화
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.179-189
    • /
    • 2005
  • 철근콘크리트 구조물의 성능저하와 관련되어 외부염소이온의 침투에 따른 철근부식은 가장 빈번하게 발생하는 현상으로 이에 따른 사용수명의 예측을 위해서는 Fick의 확산법칙을 이용한 염소이온 확산해석 방법에 대해 많은 연구가 수행되어왔다. 그러나, 탄산화가 복합적으로 작용하는 경우에 대한 연구는 최근에 이르러 수행되고 있는 실정이며 이에 따라 본 연구에서는 탄산화가 복합적으로 작용하는 경우 외부염소이온 침투에 대한 실험결과와 Fick의 확산방정식에 따른 예측결과를 비교하여 이의 타당성을 검토하였다. 이 경우 Fick의 확산방정식에 따른 깊이별 염소이온농도 예측결과는 탄산화 영역에서의 염소이온 해리에 따른 염소이온 침투촉진 현상을 적절히 반영하지 못하고 있는 것으로 나타났다. 그러나, 침지실험으로부터 구한 표면염소이온 농도 및 염소이온 확산계수를 사용하는 경우 탄산화 영역보다 깊은 영역에서의 염소이온농도는 실험결과와 비교적 일치하였다. 한편, 전기적인 촉진법에 의해 구한 염소이온 확산계수를 Fick의 확산방정식에 사용하는 경우 단순 건습반복 실험에 따른 깊이별 염소이온농도는 적절히 예측할 수 있지만 탄산화가 복합적으로 작용하는 경우에 예측된 염소이온농도는 실험결과와 많은 차이를 나타내었다. 이로부터 탄산화가 복합적으로 작용하는 경우 외부염소이온 침투정도를 조기에 예측하기 위해서는 콘크리트의 염소이온 확산계수를 적절히 측정하기 위한 새로운 방법이 요구되는 것을 알 수 있다.