• 제목/요약/키워드: Combined Deterioration

검색결과 178건 처리시간 0.038초

혹독한 환경에서의 무근콘크리트 복합열화 저감을 위한 배합설계 및 품질관리 방안 구축 (Building mix design and quality control measures to reduce the combined deterioration of plain concrete in harsh environments)

  • 김대건;박찬규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2016
  • Recently damages caused by the additional costs and degradation in durability combined deterioration due to plain concrete deterioration has occurred. In particular, in the case of the finish that is not exposed to the outside air in the concrete to respond to the harsh environment (freeze-thawing, calcium laying, etc.), to establish a quality control way for the process and the concrete mix design for it.

  • PDF

콘크리트 구조물의 단일 및 복합열화 환경하에서의 염소이온 확산특성 (Diffusion Characteristics of Chloride ion under Single and Combined Attacks in Concrete Structures)

  • 오병환;강의영;인광진;이성규;서정문
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.708-717
    • /
    • 2002
  • 해안 등 열악한 환경에 노출되는 구조물들의 건설이 증가되면서 구조물의 내구성 문제가 심각해지고 있다. 특히, 염해만이 아니라 염해와 황산염 그리고 중성화 등 복합작용에 의한 열화문제는 아직도 연구된 바가 거의 없는 실정이다. 따라서, 본 연구에서는 염해와 황산염 및 중성화가 복합된 환경하에서 콘크리트 구조물의 성능저하 현상을 살피고 이들의 상호작용과 영향을 실험적으로 구명하는데 그 목적을 두고 있다. 이를 위해서 단일 및 복합열화 실험을 포괄적으로 수행하였다. 본 연구결과, 염소이온 단일열화시 보다 황산염 또는 황산염과 중성화가 복합되었을 경우의 열화현상이 더 두드러졌으며, 모든 열화조건에서 표면염소이온의 농도는 시간에 따라 증가하고 반면에 확산계수는 시간에 따라 감소하는 경향을 나타냈다. 표면염소이온 농도는 복합열화에서 더 증가하며 특히 염소이온 확산계수는 염해와 황산염 2중 복합열화시 더 커지고 여기에 중성화가 복합될 경우 더욱 커지는 것으로 나타났다. 따라서, 해안 구조물과 같이 염해와 황산염 및 중성화가 복합될 경우 염소이온의 침투가 더욱 커져 이들의 합리적인 고려가 필요한 것으로 나타났다.

단독 및 복합열화 환경하에서 염화물을 함유한 콘크리트의 내구성 평가에 관한 연구 (The Study on the Durability Estimation of Concrete Contained Chloride ion by Individual and Combined Deterioration)

  • 김영선;문형재;조봉석;김재환;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.503-506
    • /
    • 2005
  • Recently, corrosion of reforcement of reinforced concrete structures and carbonation is raised problem of durability because of exhaustion of river sand and rapid increase of sea sand and also, concrete structure of sea environment is attacked to combined deterioration according to penetration of chloride ion and carbonation, change of temperature, repetition of dryness and wetness. Therefore, In this study, data base were presented to solve the problem about using sea sand to concrete structure situated in combined deterioration environment by exposuring concrete specimen contained chloride ion under the individual and combined deterioration.

  • PDF

바탕콘크리트의 라텍스 혼입에 따른 복합열화 저감에 관한 연구 (A Study on the Reduction of Combined Deterioration by Mixing Latex in Base Concrete)

  • 김대건
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2023
  • This study aims to mix the base concrete by mixing latex to improve the durability performance to reduce the composite deterioration of the base concrete. Latex fiber has high resistance to freezing and thawing, adhesion, and deicing agent (calcium chloride), and it is used to secure long-term durability to reduce cracking and compound deterioration of concrete. In addition, through experiments, we are trying to find ways to improve the strength of concrete by studying the mixing of the appropriate mixing ratio of latex.

  • PDF

복합열화 환경하에서 표면피복종류 및 피복두께에 따른 철근콘크리트의 부식특성 (Corrosion Properties of Reinforced Concrete with Types of Surface Cover and Covering Depth under the Combined Deterioration Environments)

  • 김무한;권영진;김용로;김재환;장종호;조봉석
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.119-126
    • /
    • 2004
  • Generally, reinforced concrete is one of the most commonly used structural materials and it prevents corrosion of steel bar by high pH of interior, But, as time elapsed, reinforced concrete structure become deteriorated by many of combined deterioration factors and environmental conditions. And, there are large number of deteriorate mechanism of the reinforced concrete structure and it acts complexly. It is recognized that steel bar corrosion is the main distress behind the present concern regarding concrete durability. In this study, to institute combined deterioration environments, established acceleration condition and cycle for combined deterioration environments has a resemblance to environments which are real structures placed. After that to confirm corrosion properties of reinforced concrete due to permeability with covering depth and types of surface cover under combined deterioration environments, measured carbonation velocity coefficients, chloride ion diffusion coefficients, water absorption coefficients, air permeability coefficients and electric potential, corrosion area ratio, weight reduction, corrosion velocity of steel bar. The results showed that an increase in age also decrease carbonation velocity coefficients, increase Chloride ion diffusion coefficients and increases water absorption coefficients. As well, an increase in age also increases corrosion of steel bar. Data on the development of corrosion velocity of steel bar with types of surface cover made with none, organic B, organic A, inorganic B, and inorganic A is shown. As well, permeability and corrosion velocity of steel bar with covering depth is superior to 10mm than 20mm. And it is confirmed permeability and corrosion properties of steel bar are closely related.

염해 및 황산염의 복합작용에 따른 염소이온 확산특성의 실험적 연구 (Experimental Study of Chlorides Ion Diffusion Characteristics under Combined Condition of Chlorides and Sulfates)

  • 오병환;김선우;정상화;서정문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.413-418
    • /
    • 2000
  • The test results on the deterioration process of concrete under single and combined action of chloride penetration have been obtained. Within the test period of 15 weeks, it is seen that the internally penetrated chloride ion contents are slightly less in the combined action of NaCI and $Na_2SO_4$ than the single action of NaCI. Also the theoretical prediction of chloride penetration based on measured diffusion coefficient agress well with the test data of single deterioration process but disagress with that of combined process. Therefore it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF

탄산화를 받은 콘크리트의 동결융해 저항성 (Resistance to Freezing and Thawing of Concrete Subjected to Carbonation)

  • 이승태;박광필
    • 한국산학기술학회논문지
    • /
    • 제19권2호
    • /
    • pp.623-631
    • /
    • 2018
  • 공용중인 콘크리트 구조물의 내구성 연구는 한 가지 원인에 대한 단독열화 연구를 주로 연구하였지만 실제 구조물의 공용시기에는 두 가지 이상의 환경에 노출되어 있어 이러한 복합열화에 대한 관심이 최근 증가하고 있는 실정이다. 복합열화에 대해 일반적으로 염해와 동결융해에 대해서는 일부 연구가 진행되어 있지만 콘크리트의 양생 직후부터 발생하는 탄산화와 다른 내구성능저하에 대한 복합열화 연구는 매우 미흡한 실정이다. 특히, 탄산화를 중심으로 하는 복합열화는 탄산화의 경우 탄산화 진행시 콘크리트 조직이 치밀해진다는 문헌고찰에 따라 조직의 치밀해지는 이유로 연구가 미흡하다. 본 연구에서는 콘크리트의 탄산화 및 동결융해에 대한 복합열화를 평가 분석한 결과이다. 평가를 위하여 탄산화된 콘크리트를 동결융해 300싸이클까지 복합열화 시험을 실시하여 동탄성계수와 압축강도를 측정하였다. 그 결과 물-결합재비에 대한 영향 평가에서 35 %의 콘크리트가 55 %의 콘크리트에 비해 복합열화 성능이 낮은 것을 확인하였고, 광물질혼화재료를 사용한 경우 플라이애시와 고로슬래그미분말을 사용한 경우 동일 물-결합재비에서 보통포틀랜드 시멘트 사용 콘크리트보다 복합열화에 대한 성능이 개선되는 것으로 나타났다.

중성화와 염해를 고려한 콘크리트의 복합열화 예측 (Prediction of Deterioration Process for Concrete Considering Combined Deterioration of Carbonation and Chlorides Ion)

  • 이창수;윤인석
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.902-912
    • /
    • 2003
  • 전 세계적으로 콘크리트 구조물의 열화를 발생하는 가장 중요한 원인은 중성화와 염소이온이다. 대체적으로 많은 콘크리트 구조물에서 염소이온과 중성화로 인하여 철근이 부식되며 이에 대한 많은 연구가 이루어지고 있다. 그러나 실구조물의 상황은 염소이온과 중성화가 복합적으로 발생함에도 불구하고 많은 연구들이 각각의 단일열화에 대한 연구가 이루어지고 있으며 복합열화에 대한 연구는 매우 드문 상황이다. 본 연구는 2중 복합 매체에 대한 확산모델을 이용하여 중성화된 콘크리트의 염소이온 프로파일을 예측하고자 하였다. 실험결과에 의하여 중성화 깊이로부터 3∼5 mm영역에 염소이온의 농축현상이 발생하였으며 2중 복합 구조체에 적용할 수 있는 확산 방정식에 중성화된 콘크리트와 비중성화된 콘크리트의 시간의존적인 염소이온 확산 계수를 고려하여 내구수명예측에 반영하였다.

염화물 및 황산염 복합환경 하에서의 열화특성에 관한 실험적 연구 (Experimental Study on Deterioration Characteristics under Combined Exposure Conditions of Chlorides and Sulfates)

  • 오병환;인광진;강의영;김지상;서정문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.771-776
    • /
    • 2001
  • Test results on the deterioration process of concrete under single and combined attacks of chloride penetration have been obtained. After test period of 52 weeks, it is found that the internally penetrated chloride ion contents are less in the single attacks of chloride than the combined attacks of chloride and sulfate. Both the diffusion coefficients and surface chloride concentration derived form the chloride profiles showed a time dependence. Also the performance of fly ash-blended cements was observed to be better than plain cements in retarding chloride attack. However it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF

동해와 염해를 동시에 받는 콘크리트의 복합열화에 관한 연구 (A Study on the Combined Deterioration of Concrete subjected to Freezing-Thawing and Chloride Attack)

  • 김은겸;최상덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.225-228
    • /
    • 2005
  • This paper was accomplished for analyzing the reason of the above deterioration happened on the deck of concrete bridge. The bridge was constructed at 660m above the sea level having more freezing and snowing days. Therefore, it is placed on the particular condition sprinkling $CaCl_2$ enough for keeping up with moderate traffic condition. When it is considered to the former condition, the bridge can be assumed to potentialities for combined deterioration with freezing-thawing under sprinkling deicing chemical. Core specimens were gathered from the concrete deck for clearing the reason of the above deterioration exactly, and it is used for various tests for measuring the compressive strength, elastic modulus, content of $Cl^-$, freezing-thawing at the fresh and salt water. As a result of freezing-thawing test, the specimen at the fresh water has over 90$\%$ of durability factor, but another specimen at 1$\%$ of salt water has 0$\%$ of durability factor at 140 cycles of the freezing-thawing. The result means that frost damage is sccelerated at the salt water. Therefore, the deterioration of the concrete deck is estimated to be occured by combined effects of freezing-thawing and chloride ion attack.

  • PDF