• Title/Summary/Keyword: Collection 6

Search Result 2,688, Processing Time 0.035 seconds

Enhancement of signal-to-noise ratio for uroflowmetric test regardless of urination situation (요속검사시 배뇨상황에 무관한 신호대잡음비 개선 기법)

  • Kim, Kyung-Ah;Choi, Seong-Su;Lee, Sang-Bong;Kim, Kyoung-Oak;Park, Kyung-Soon;Shin, Eun-Young;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.423-431
    • /
    • 2009
  • Standard uroflowmetry measures the urine weight using single load cell to evaluate the urinary flow rate. Impact noise should be introduced due to gravity when the urine stream falls down into the container upon the load cell. The present study placed three load cells on the three vertices of a regular triangle and the three signals were ensemble averaged to enhance the signal-to-noise ratio(SNR) regardless of how the urination was made. Simulated urination experiment was performed with three different urine collection methods. In all three methods, SNR of the averaged signal was much higher than each load cell signals. With no urine collection device, the present signal averaging technique resulted in SNR values higher by 10~15 dB than when dual funnels or upper funnel were used to guide the urine stream. Therefore, it was demonstrated that the three point measurement followed by with ensemble averaging could enable accurate uroflowmetric test without any specially made urine collection devices.

Studies on Reproductive Capacity of Korean Native Bulls II. Effect of collection Frequency on Semen Characteristics and Sexual Activity in 2-Year-Old Bulls (한우종모우의 번식능력에 관한 연구 II. 2재종모우의 정액채취빈도가 정액성장 및 성적활동에 미치는 영향)

  • 김창근;정영채;김종대;김선환
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.1
    • /
    • pp.40-45
    • /
    • 1985
  • Eight 2-yr old bulls from Artificial Breeding Center, NLCF were used to determine the effectof collection frequency on semen characteristics and sexual activity. Two successive ejaculates per day were collected by artificial vagina for 4 weeks on weekly or twice a week. Total ejaculate volume included 2nd ejaculates for one time and two time bulls was 6.8ml and 6.0ml, but there was no significant difference between collection intervals. Sperm concentration of one time and two time bulls averaged 0.79$\times$109/ml and 0.89$\times$109/ml, respectively. Total sperm per ejaculate was 5.14$\times$109 for one time bulls and 5.45$\times$10 for two time bulls. Two time bulls had slight more sperm per ml and ejaculate than one time bulls, but there were no significant differences between two group bulls. Sperm motility and semen pH of two time bulls was slightly better than that of one time bulls. In changes of bulk minerals in semen, solium concentration of two time bulls was similar to that of one time bulls. Potassium and calcium was more concentrated in one time bulls than in two time bulls, but these concentrations did not differ significantly. Libido score for two time bulls was higher than that for one time bulls. However, there was no difference between two groups and these scores did not change for 4 weeks in two goups. Total time to 2nd ejaculation was 16.3 sec for one time bulls and 20.5 sec for two time bulls.

  • PDF

Analysis of Percentage of Arcing between Pantograph and Overhead Contact Line as a Function of Duration of Arc (팬터그래프와 전차선간 최소 이선아크 지속시간에 따른 이선율 변화량 분석)

  • Park, Young;Lee, Kiwon;Kwon, Sam-Young;Park, Chulmin;Kim, Jae-Kwang;Choi, Won Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.855-859
    • /
    • 2014
  • Quality criteria for interaction between a pantograph and overhead contact wire is a most important requirement to assess of the performance for the current collection system. Interaction performance between pantograph and catenary system is subject to approval by the infrastructure manager when a new design and contraction of overhead contact line and pantograph are installed. Among the various performance, percentage of arcing at maximum line speed is a simple test method compared with contact force of pantograph due to direct sensing of pantagraph, calibrations, installations of train, and etc. On the other hand, percentage of arcing is need to reliable arcing detector and general requirements with accordance with EN 50317. In this paper, percentage of arcing are investigated on the function of duration of arc and proposed which is satiable of percentage of arcing. As a results, we proposed which duration of arcs are unsuitable from infrastructures point of view as performance testing for quality of current collection.

Using 3D image-based body shape Measurement to increase the accuracy of body shape Measurement (체형 측정의 정확도를 높이기 위한 3차원 영상 기반의 체형 측정 활용)

  • So, Ji Ho;Jeon, Young-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.803-806
    • /
    • 2020
  • The body shape measurement method using 3D images has been widely used due to the recent development of 3D measurement cameras and algorithms. Existing 3D imaging devices are expensive devices, and there is a limit to their universalization. Due to the recent spread of inexpensive 3D cameras and the development of various measurement methods, various possibilities are being shown. It is expected to have a great impact on the medical device market that requires accurate data collection. Various medical device products using artificial intelligence are emerging, and accurate data collection is the most important to develop accurate artificial intelligence algorithms. Collection equipment using 3D cameras is expected to act as a major factor in the development of artificial intelligence algorithms using 3D images.

A Novel Data Collection Algorithm Based on Mobile Agent to Improve Energy Efficiency in Wireless Sensor Networks (무선 센서 네트워크에서 에너지 효율 향상을 위한 이동 에이전트 기반 데이터 수집 알고리즘)

  • Yang, Myungjoon;Kim, Jinhyuk;Choi, Sangbang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.8
    • /
    • pp.528-537
    • /
    • 2014
  • Wireless Sensor Network(WSN) is a network which consists of sensor nodes(SNs) in data collection area. It is hard for the SNs to replace battery. Thus energy and transfer efficiency is important because the energy is limited. In this paper, we propose energy-efficient data collection algorithm for wireless sensor networks by using mobile agent in distance-based cluster structure. For avoid collisions and guarantee low latency, make distance-based topology and build cluster by the topology. For performance comparison of the proposed algorithm, compare with existing mobile agent algorithm. When network constructed by 300 nodes, proposed algorithm has performance increase than existing algorithm(GCF, LCF, TBID) in network lifetime 194, 124.6, 1.46 times each and data merging energy efficiency 87.5%, 85%, 45% each.

Landfill gas-landfill degassing system and methods of using landfill gas at Sarajevo landfill

  • Dzevad Imamovic;Amra Serdarevic
    • Coupled systems mechanics
    • /
    • v.12 no.6
    • /
    • pp.531-537
    • /
    • 2023
  • Municipal solid waste landfills are unpredictable bioreactors which in cases of mishandling and bad supervision presents numerous risks. The key to municipal waste landfills is to approach them from the point of prevention of the possible consequences, which means using methods of organized waste disposal, and also utilizing landfill gas, as an unavoidable consequence with disposal of municipal solid waste with a high share of biodegradable organic matter. This paper presents an overview about problems of solid municipal waste management, type and composition of waste, and an overview of waste management condition. Further, the problem of landfill and landfill gasses is described with the calculation models of landfill production, as well as the use of the SWM GHG Calculator and LandGEM software on a specific example of gas production for the central zone at Sarajevo landfill "Smiljevici". Main focus of this thesis is the analysis of potentials of greenhouse gas emission reduction measures from the waste management. Overview of the best available techniques in waste management is presented as well as the methodology used for calculations. Scenarios of greenhouse gas emission reduction in waste management were defined so that emissions were calculated using the appropriate model. In the final section of the paper, its description of the problem of collection and utilization the landfill gas at the sanitary landfill "Smiljevici", and implementation of the system for landfill gas collection and solution suggestion for the gasification and exploitation of gas. Energy, environmental and economic benefits can be accomplished by utilizing municipal solid waste as fuel in industry and energy and moreover by utilizing energy generation from landfill gas, which this thesis emphasizes.

Minimization Method of Data Collection Delay Time for Bus Information System (버스정보 수집지연시간 최소화 방안 연구)

  • Lim, Seung-Kook;Kim, Young-Chan;Ha, Tae-Jun;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.81-91
    • /
    • 2008
  • In this study, data collection delay time generated in bus information system is analysed and improvement on system reliability by minimizing the delay time is suggested. To minimize the data collection delay time (call setup time), factors on data collection phase are analyzed. Each connecting time that it occurs from wireless communication during data collection phase, is selected as a main effective variable and a model for selecting an optimum communication point to minimize the effect of data delay time by each connecting time is suggested. In this model, minimization of the point between the time carrying out wireless communication and vehicle moving time, is calculated and the difference between the bus arrival time and information delivered time to the passenger is reduced. The test results for the proposed model in BIS using a CDMA (Code Division Multiple Access) communication show that delay time in real system operation has been improved. The minimum data collection delay time based on optimal communication position leads to the better reliability for Bus Information System. This study can be applied to the selection of optimal communication position and detection position instead of empirical methods.

  • PDF

Screening for Cold-Active Protease-Producing Bacteria from the Culture Collection of Polar Microorganisms and Characterization of Proteolytic Activities (남북극 유래 저온성 박테리아 Culture Collection에서 저온활성 프로테아제 생산균주의 스크리닝과 효소 특성)

  • Kim, Doc-Kyu;Park, Ha-Ju;Lee, Yung-Mi;Hong, Soon-Gyu;Lee, Hong-Kum;Yim, Joung-Han
    • Korean Journal of Microbiology
    • /
    • v.46 no.1
    • /
    • pp.73-79
    • /
    • 2010
  • The Korea Polar Research Institute (KOPRI) has assembled a culture collection of cold-adapted bacterial strains from both the Arctic and Antarctic. To identify excellent protease-producers among the proteolytic bacterial collection (874 strains), 78 strains were selected in advance according to their relative activities and were subsequently re-examined for their extracellular protease activity on $0.1{\times}$ ZoBell plates supplemented with 1% skim milk at various temperatures. This rapid and direct screening method permitted the selection of a small group of 15 cold-adapted bacterial strains, belonging to either the genus Pseudoalteromonas (13 strains) or Flavobacterium (2 strains), that showed proteolytic activities at temperatures ranging between $5-15^{\circ}C$. The cold-active proteases from these strains were classified into four categories (serine protease, aspartic protease, cysteine protease, and metalloprotease) according to the extent of enzymatic inhibition by a class-specific protease inhibitor. Since highly active and/or cold-adapted proteases have the potential for industrial or commercial enzyme development, the protease-producing bacteria selected in this work will be studied as a valuable natural source of new proteases. Our results also highlight the relevance of the Antarctic for the isolation of protease-producing bacteria active at low temperatures.

Consideration for Setting Reference Range for Adrenocorticotropic Hormone Test according to Blood Collection Time (채혈 시간에 따른 부신피질 자극 호르몬 검사의 참고치 설정에 관한 고찰)

  • Ji-Hye Park;Jin-Ju Choi;Soo-Yeon Lim;Seon-Hee Yoo;Sun-Ho Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.42-46
    • /
    • 2023
  • Purpose The reference range described in Adrenocorticotropic Hormone reagent used in our laboratory is 10-60 pg/mL at 8 a.m. to 10 a.m., and 6-30 pg/mL at 8 p.m. to 10 p.m. However, in the case of outpatients, blood is mainly collected between 10 a.m. and 6 p.m., accounting for 57.8% of the total. Therefore, This study is intended to help make a more accurate diagnosis by reevaluating the reference range provided by the manufacturer of the Adrenocorticotropic Hormone reagent and setting split-timed reference range. Materials and Methods The patients collected blood before 10 a.m. were group A (68 people), and the patients collected blood after 10 a.m. were set to group B (80 people). A T-test was performed between groups to test their significance. And it was confirmed whether it was necessary to set the gender classification as a subgroup. The method of setting the reference range was calculated by the Bayesian's method and the Hoffmann's method. Results The reference range of Group A was 8.6 to 60.6 pg/mL by the Bayesian's method, and the Hoffmann's method was 3.6 to 61.3 pg/mL. The reference range of Group B was 6.9 to 50.5 pg/mL when applying the Bayesian's method, and the Hoffmann method's was 2.3 to 48.9 pg/mL. Conclusion This study was concluded that it was necessary to set the split-timed reference range. Through this study, the later the blood collection time, the lower the level of Adrenocorticotropic Hormone, indicating that blood collection time is important for patients with clinical significance. If a large number of subjects are selected and supplemented in the future, it is believed that systematic and accurate reference range can be set.

  • PDF