• Title/Summary/Keyword: Collapse disaster site

Search Result 25, Processing Time 0.042 seconds

A Study on the Manual for Emergency Medical Facility Constructing at Disaster Site (재난현장 응급의료시설 구축을 위한 매뉴얼에 관한 연구)

  • Yoon, Yousang;Suh, Sangwook;Lee, Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.6
    • /
    • pp.38-46
    • /
    • 2017
  • Recently, various types of disasters have been occurring all over the world, and the importance of disaster management system to minimize damage caused by disasters is emerging. In Korea, we have made many policy improvements related to disaster safety, such as the establishment of the National Security Service and the announcement of the National Safety Management Plan and made a lot of effort to secure facilities such as disaster relief hospitals after the Mauna Ocean Resort Gymnasium Collapse and the Sewol-ho incident, However, compared to advanced countries such as the US, Europe, and Japan, there is a shortage of emergency medical center per population, and disaster management systems have not been implemented efficiently due to lack of coordination among various agencies. The purpose of this study is to propose the efficient construction and systematic management of emergency medical facilities required for disaster situations. For this purpose, it is necessary to identify the current status of domestic emergency medical facilities compared to developed countries.

A Study on the Management of Construction Project for Preventing Accidents of Reclamation : basic on the collapse of Sangdo Kindergarten (도심지 소규모 재개발·재건축공사시 흙막이가시설 사고예방을 위한 건설사업관리 방안 연구 : 상도유치원 붕괴사고 중심으로)

  • Oh, Se-kil;Park, Joo-Moon
    • Journal of Urban Science
    • /
    • v.8 no.1
    • /
    • pp.33-44
    • /
    • 2019
  • The purpose of this study is to investigate the cause of repeated accidents through the investigation and analysis of the collapse cases of domestic earthquakes in order to prevent the earthquake disaster in the urban redevelopment and reconstruction. It is designed and constructed to draw out various problem factors and to find solutions to these problems. And the contents related to various laws and systems of the construction project management stage. Especially. In the management of the construction management centered on the safety management and quality control of the technical aspect design, supervision, construction phase through the cause of the accident and improvement measures based on the investigation report of the collapse of the construction site near Sangdo Kindergarten in Seoul. Supervisor. And constructors should be settled on the responsibility and responsibility of God. In order to achieve the purpose of the project, a system is established to link worker-centered occupational safety and health management with technology-based safety construction management, and analysis of how the quality control of the earthquake prevention affects safety construction management The purpose of this study is to prepare the optimum management plan of construction business.As a result of this study, it is aimed to accomplish the purpose of small scale redevelopment and reconstruction construction project by providing optimization method in the stage of construction project management in order to prevent collapse caused by differences in design,Is expected.

A Study on Applying 3D Automatic Displacement Measurement System for Safety Monitoring of Building Demolition Works (건축물 해체공사 안전 모니터링을 위한 3차원 자동변위계측 시스템 활용 방안 연구)

  • Park, Han-Bin;Han, Hye-Rim;Kim, Taehoon;Cho, Kyuman;Cho, Chang-Geun;Kim, Hyeong-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.229-230
    • /
    • 2022
  • According to the national building status, there are a total of 2.89 million buildings that are over 30 years old after completion, and the number is increasing by more than 70,000 to 80,000 buildings every year. As a result, the demand for demolition works is also increasing, and more than 3 to 4 collapse accidents occur steadily every year during demolition work. Major causes of accidents include non-compliance with plans, negligence of on-site supervisors, and failure to secure structural safety. Due to the strengthening of the Severe Disaster Punishment Act, there is growing interest in the demand for secure management of collapse detection during demolition works. Therefore, this study aims to investigate the applicability of real-time safety monitoring systems using a total station capable of 3D automatic displacement measurement in building demolition work for securing structural safety by the load changes during the demolition process.

  • PDF

A Preliminary Study on Mobile Medical Unit for Emergency Medical System (응급 의료체계용 이동 의료단위에 대한 기초연구)

  • Yang, Minkyu;Lee, Young;Suh, Sangwook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.6
    • /
    • pp.57-64
    • /
    • 2017
  • Recently, the disaster situation has been diversified and compounded worldwide as well as in Korea. And the damage scale of each disasters have increased, and following economic loss is also increasing immensely. In Korea, especially the out break frequency of large-scale disasters has increased. Disasters caused by earthquakes are also very likely to occur. When a major accident such as Mauna resort collapse accident, Ferry sewol sinking accident occurred, systematic emergency medical care at the site at the time of disaster occurred in order to operate an emergency medical facility corresponding to the site, which is not systematic. The need for this service is urgent. If highly reliable emergency medical system function at appropriate times in the disaster site, secondary damage can be reduced and the whole situation would be back to normal shortly. Therefore, it is necessary to provide an emergency medical system capable of quickly and safely responding to disaster sites in relation to various damage scale. For the purpose, thorough analysis on mobile medical units of inside and outside the country was accomplished. As a result, Mobile Medical Unit of outside the country are trailer type, tent type, container type etc. At home, these types have been studied and will be proposed early next year as a temporary solution. Here we introduce suitable types for our country.

Assessment of Lifeline Construction Technology for Buried Alive in Building Collapse (도심지 붕괴사고에 따른 매몰지역 생명선 시공기술 평가)

  • Ryu, Byung-Hyun;Kang, Jae-Mo;Lee, Jangguen;Kim, Young-Sam;Joo, Rak-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.9
    • /
    • pp.47-52
    • /
    • 2016
  • Unusual extreme weather events, which exceed a safe design capacity of the infrastructure, increase the frequency of natural disasters and has also been enlarged damage scale. Aging buildings and rapid urban progress act as weighting factors for the new composite disasters. Technological advances support detecting pre-disaster risk, real-time data analysis, and rapid response to the disaster site, but it is insufficient that emergency relief for buried alive must take advantage of the proven technologies through field tests. This study aims to evaluate directional drilling performance through underground soils and the reinforced concrete structure for primary lifeline installation in order to quickly provide relief supplies for buried alive when urban structures collapse.

Research on the Establishment of Contractor Centered Safety Management System to Reduce Construction Disaster (건설재해 저감을 위한 발주자 중심의 안전관리체계 구축에 관한 연구)

  • Kia, Seongho;Park, Namkwun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.503-510
    • /
    • 2014
  • Large scale construction disasters such as recent Noryangjin flooding incident and Banghwadaegyo collapse accident are occurring persistently. Thereupon, the role and responsibility of the various construction participants are considered as major element to reduce disaster at the construction site. Construction industry is a process of building construction object by going through planning, designing, constructing, and maintenance controlling in which various bodies of act, from contractor to designer and builders, participate. However, the subject of current safety supervision is focused on the builder, the contract enterprise which directly employs workers, while the safety activity participation of the contractor, who exerts decision-making authority at the highest level, is excluded. Therefore, this study understands the level of awareness and reality on the safety activity of each construction participants from which the improvement plan on the contractor centered safety management system is proposed.

Fabrication of Three-Dimensional Scanning System for Inspection of Massive Sinkhole Disaster Sites (대형 싱크홀 재난 현장 조사용 3차원 형상화 장비 구현)

  • Kim, Soolo;Yoon, Ho-Geun;Kim, Sang-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.341-349
    • /
    • 2020
  • Recently, interest in ground subsidence in urban areas has increased after a large sinkhole occurred near the high-story building area in Jamsil, Seoul, Korea, in 2014. If a massive sinkhole occurs in an urban area, it is crucial to assess its risk rapidly. Access to humans for on-site safety diagnosis may be difficult because of the additional risk of collapse in the disaster area. Generally, inspection using drones equipped with high-speed lidar sensors can be utilized. However, if the sinkhole is created vertically to a depth of 100 m, similar to the sinkhole in Guatemala, the drone cannot be applied because of the wireless communication limit and turbulence inside the sinkhole. In this study, a three-dimensional (3D) scanning system was fabricated and operated using a towed cable in a massive vertical sinkhole to a depth of 200 m. A high-speed lidar sensor was used to obtain a continuous cross-sectional shape at a certain depth. An inertial-measuring unit was applied to compensate for the error owing to the rotation and pendulum movement of the measuring unit. A reconstruction algorithm, including the compensation scheme, was developed. In a vertical hole with a depth of 180 m in the mining area, the fabricated system was applied to scan 0-165 m depth. The reconstructed shape was depicted in a 3D graph.

A Study on Quality Management Improvement of Used Pipe Support(V2) (재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구)

  • Park, Jongkeun;Choi, Myeongki
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

A Experimental Study on Performance Improvement Factors of Used V4 Steel Pipe Support (재사용 V4 강재 파이프 서포트의 성능향상 요인에 관한 실험적 연구)

  • Choi, Myeongki;Park, Jongkeun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • It is considered that most of reusable pipe supports, which are used as formwork support posting at construction sites, do not meet the performance standard. Due to the use of reusable pipe supports that do not meet such performance standard the potential risk of collapse accident is increasing. Therefore, this study identifies the status of compliance with performance standard, and presents the requirements for improving quality control to prevent the collapse of pipe supports reused at the construction site. First, if the female thread of the product with no clearance and new support pin with the diameter of 12mm are replaced at the same time for use, it is considered that the performance will be improved. Second, as the quality performance during use can be improved in the case of larger thickness of inner diameter compared to the case of larger thickness of outer diameter, it is necessary to increase the inner pipe thickness greatly than the current thickness. Based on the results of this study, it is expected that the performance the reusable pipe support (V4) can be improved, if the diameter of the support pin is 12mm, the female thread has a small clearance, and the inner tube thickness is 2.3 ~ 2.7mm. In addition, it is considered that other performance improvement factors included in the study results could be used as important data for improving the performance of reusable pipe support.

Crack Form and Soil Physical Properties in Land Creeping area on Okjong, Hadong (하동군 옥종면 땅밀림 산사태지의 인장균열 형태와 토양 물리성 변화)

  • Kim, Ki-Dae;Park, Jen-Hyeon;Lee, Chang-Woo;Kang, Min-Jeng
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.435-440
    • /
    • 2016
  • This study was carried out to examine of soil physical property and crack shape by collapse process on landslide area (by land creeping) in Hadong, Gyeongnam. We investigated morphological characteristics (length, depth, cut slope) between main crack and local crack, soil physical properties change between undisturbed section and disturbed section. As a result, morphological characteristics of crack showed no significant difference main crack between local crack. In case of soil physical property variation, soil liquid phase was significantly higher at 31-40 cm of soil depth in disturbed section. And this result is likely to be due to site factors.