• Title/Summary/Keyword: Collapse Test

검색결과 484건 처리시간 0.024초

Seismic and progressive collapse assessment of SidePlate moment connection system

  • Faridmehr, Iman;Osman, Mohd Hanim;Tahir, Mahmood Bin Md.;Nejad, Ali Farokhi;Hodjati, Reza
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.35-54
    • /
    • 2015
  • The performance of a newly generated steel connection known as SidePlateTM moment connection for seismic loading and progressive collapse phenomenon has been investigated in this paper. The seismic evaluation portion of the study included a thorough study on of interstory drift angles and flexural strengths based on 2010 AISC Seismic Provisions while the acceptance criteria provided in UFC 4-023-03 guideline to resist progressive collapse must be satisfied by the rotational capacity of the connections. The results showed that the SidePlate moment connection was capable of attaining adequate rotational capacity and developing full inelastic capacity of the connecting beam. Moreover, the proposed connection demonstrated an exceptional performance for keeping away the plastic hinges from the connection and exceeding interstory drift angle of 0.06 rad with no fracture developments in beam flange groove-welded joints. The test results indicated that this type of connection had strength, stiffness and ductility to be categorized as a rigid, full-strength and ductile connection.

Chord rotation demand for effective catenary action of RC beams under gravitational loadings

  • Tsai, Meng-Hao
    • Structural Engineering and Mechanics
    • /
    • 제58권2호
    • /
    • pp.327-345
    • /
    • 2016
  • Many experimental and analytical studies have been conducted with beam-column subassemblages composed of a two-span beam to investigate the progressive collapse resistance of RC frames. Most study results reveal a strength-decreased transition phase in the nonlinear static load-deflection curve, which may induce dynamic snap-through response and increase the chord rotation demand for effective catenary action (ECA). In this study, the nonlinear static response is idealized as a piecewise linear curve and analytical pseudo-static response is derived for each linearized region to investigate the rotation demands for the ECA of the two-span RC beams. With analytical parameters determined from several published test results, numerical analysis results indicate that the rotation demand of 0.20 rad recommended in the design guidelines does not always guarantee the ECA. A higher rotation demand may be induced for the two-span beams designed with smaller span-to-depth ratios and it is better to use their peak arch resistance (PAR) as the collapse strength. A tensile reinforcement ratio not greater than 1.0% and a span-to-depth ratio not less than 7.0 are suggested for the two-span RC beams bridging the removed column if the ECA is expected for the collapse resistance. Also, complementary pseudo-static analysis is advised to verify the ECA under realistic dynamic column loss even though the static PAR is recovered in the nonlinear static response. A practical empirical formula is provided to estimate an approximate rotation demand for the ECA.

Collapsed L4 Vertebral Body Caused by Brucellosis

  • Ekici, Mehmet Ali;Ozbek, Zuhtu;Kazanci, Burak;Guclu, Bulent
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권1호
    • /
    • pp.48-50
    • /
    • 2014
  • Brucellosis is caused by gram-negative, aerobic, non-motile, facultative, intracellular coccobacilli belonging to the genus Brucella. A 50-year-old man working as an employee was admitted to neurosurgery clinic with severe low back, radicular right leg pain and hypoesthesia in right L4-5 dermatomes for 2 months. Brucella tube agglutination (Wright) test was positive in serum sample of the patient with a titer of 1/640. Brucella melitensis was isolated from blood culture. X-ray and MRI of the lomber spine showed massive collapse of L4 vertebral body. Neural tissue was decompressed and then posterior L3-5 short segment transpedicular screw fixation and stabilization was performed. Brucella melitensis was isolated from microbiologic culture of pathologic specimen. Antibiotic therapy was given as doxycycline 200 mg/day and rifampicin 600 mg/day for 6 months. Brucellosis is a systemic zoonotic infection and still an important public health problem in many geographical parts of the world. Vertebral body collapse caused by brucellosis occurs very rarely but represents a neurosurgical emergency because of its potential for causing rapidly progressive spinal cord compression and permanent paralysis. Neurosurgeons, emergency department personnel as well as infectious disease specialists should always keep a high index of suspicion and include brucellosis in the differential diagnosis of vertebral body collapse.

A new procedure for load-shortening and -elongation data for progressive collapse method

  • Downes, Jonathan;Tayyar, Gokhan Tansel;Kvan, Illia;Choung, Joonmo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권6호
    • /
    • pp.705-719
    • /
    • 2017
  • Progressive Collapse Method (PCM) has been broadly applied to predict moment-carrying capacity of a hull girder, however accuracy of PCM has not been much studied. Accuracy of PCM is known to be dependent on how Load-Shortening and -Elongation (LSE) curve of a structural units are well predicted. This paper presents a new procedure to determine LSE datum based on box girder Finite Element Analyses (FEAs) instead of using finite element model of stiffened panels. To verify reliability of FEA results, the simple box girder collapse test results are compared with FEA results of same box girders. It reveals one frame-based box girder model is sufficiently accurate in terms of ultimate strengths of the box girders. After extracting LSE data from the box girders, PCM-based moment-carrying capacities are compared with those from FEAs of the box girders. PCM results are found to be equivalent to FEAs in terms of moment-carrying capacity if accurate LSE data are secured. The new procedure is applied to well-known 1/3 scaled frigate full section. Very excellent moment-carrying capacity of frigate hull section is obtained from PCM with LSE data from box girder FEAs.

EMTP를 이용한 전압 불안정 현상의 동적 시뮬레이션 (A Dynamic Simulation of Voltage Instability Using EMTP)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.295-300
    • /
    • 2003
  • Voltage instability has been studied for some decade now. But, There is not generally accepted definition of voltage instability because of the complex phenomenon and the variety of ways in which it can manifest itself. Both IEEE and CIGRE have the respective definitions. The areas of voltage instability research are the analysis, simulation and countermeasure of voltage instability. It needs to model the components of the power system to simulate the voltage instability and voltage collapse. At the beginning, the static simulation was used. This method provides the voltage stability indices and it requires less CPU resource and gives much insight into the voltage and power problem. However, it is less accurate than the dynamic simulation peformed in the time domain simulation. So, when it appears difficult to secure the voltage stability margin in a static stability, it is necessary to perform the dynamic simulation. To perform time-domain simulation, we have to model the dynamic component of the power system like a generator and a load. The dynamic simulation provides the accurate result of the voltage instability. But, it is not able to provide the sensitivity information or the degree of stability and it is time consuming and it needs much CPU resource. In this Paper, we perform a dynamic simulation of voltage instability and voltage collapse using EMTP MODELS. The exponential load model is designed with MODEIS and this load model is connected with test power system. The result shows the process of voltage change in time domain when the voltage instability or voltage collapse occurs.

두개의 평행한 축방향 관통균열이 존재하는 증기발생기 세관의 최적 파손예측모델 (Optimum Failure Prediction Model of Steam Generator Tube with Two Parallel Axial Through-Wall Cracks)

  • 이진호;송명호;최영환;김낙철;문성인;김영진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1186-1191
    • /
    • 2003
  • The 40% of wall criterion, which is generally used for the plugging of steam generator tubes, may be applied only to a single crack. In the previous study, a total of 9 failure models were introduced to estimate the local failure of the ligament between cracks and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however, known that parallel axial cracks are more frequently detected during an in-service inspection than collinear axial cracks. The objective of this study is to determine the plastic collapse model which can be applied to the steam generator tube containing two parallel axial through-wall cracks. Nine previously proposed local failure models were selected as the candidates. Subsequently interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed for the determination of the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a plastic zone contact model was selected as an optimum model.

  • PDF

Optimum Global Failure Prediction Model of Inconel 600 Thin Plate with Two Parallel Through-Wall Cracks

  • Moon Seong In;Kim Young Jin;Lee Jin Ho;Song Myung Ho;Choi Young Hwan
    • Nuclear Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.316-326
    • /
    • 2004
  • The $40\%$ of wall criterion, which is generally used for the plugging of steam generator tubes, is applied only to a single crack. In a previous study, a total number of 9 failure models were proposed to estimate the local failure of the ligament between cracks, and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however known that parallel axial cracks are more frequently detected than collinear axial cracks during an in-service inspection. The objective of this study is to determine the plastic collapse model that can be applied to steam generator tubes containing two parallel axial through-wall cracks. Three previously proposed local failure models were selected as the candidates. Subsequently, the interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed to determine the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a COD base model was selected as an optimum model.

Estimation of Collapse Moment for Wall Thinned Elbows Using Fuzzy Neural Networks

  • Na, Man-Gyun;Kim, Jin-Weon;Shin, Sun-Ho;Kim, Koung-Suk;Kang, Ki-Soo
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.362-370
    • /
    • 2004
  • In this work, the collapse moment due to wall-thinning defects is estimated by using fuzzy neural networks. The developed fuzzy neural networks have been applied to the numerical data obtained from the finite element analysis. Principal component analysis is used to preprocess the input signals into the fuzzy neural network to reduce the sensitivity to the input change and the fuzzy neural networks are trained by using the data set prepared for training (training data) and verified by using another data set different (independent) from the training data. Also, two fuzzy neural networks are trained for two data sets divided into the two classes of extrados and intrados defects, which is because they have different characteristics. The relative 2-sigma errors of the estimated collapse moment are 3.07% for the training data and 4.12% for the test data. It is known from this result that the fuzzy neural networks are sufficiently accurate to be used in the wall-thinning monitoring of elbows.

탄질 셰일 파쇄구간에서 터널 붕락부 거동 및 보강 연구 (Auxiliary Reinforcement Method for Collapse of Tunnel in the Coal Shale Fractured Zone)

  • 김낙영;문창열;박용석
    • 한국지반환경공학회 논문집
    • /
    • 제8권6호
    • /
    • pp.85-95
    • /
    • 2007
  • 탄질 셰일 파쇄대의 경우, 물리탐사의 사전조사방법으로 그 여부를 파악하기 어렵고 또한, 용수등에 노출이 안되는 경우 탄질 셰일층 강도 자체는 양호한 특성이 있다. 그러나 이러한 탄질 셰일층의 경우 용수에 접하거나 대기에 노출되는 경우 단기간내에 강도가 급격히 저하되거나 풍화가 급속히 진전되는 매우 취약한 특성이 있다. 따라서 사전 예측하기가 어렵고 붕락발생시 급작스럽게 발생하는 경우가 대부분이다. 강도감소 측면에서는 용수와 접할시, 탄층 세일 파쇄대층에 대한 점하중 강도 시험결과 12시간 경과후 강도가 56%감소하였다. 또한 본 논문에서는 탄질 셰일 파쇄구간에 대한 표준 보강단면을 제시하였다.

  • PDF

단순 보모델을 이용한 측면충돌 해석기술 연구 (A Study on Side Impact Simulation Technique using Simple Beam Model)

  • 강성종
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.170-177
    • /
    • 1997
  • In this study, an analysis technique using simple beam model for predicting structure crashworthiness of the passenger car side impacted with an angle by another passenger car was investigated. The simple model was composed of major beam-like side structure which carry almost all side impact load. A procedure of component collapse test, calculation of load carrying capability and dynamic simulation was carryed out sequentially. Transient dynamic algorithms and a computer program to simulate deformations and motions of the impacted car was developed. The developed procedure was applied to a 3 door passenger car side impacted with an angle of 75 degree and the analysis results show good agreements with the actual test results.

  • PDF