Optimum Failure Prediction Model of Steam Generator Tube with Two Parallel Axial Through-Wall Cracks

두개의 평행한 축방향 관통균열이 존재하는 증기발생기 세관의 최적 파손예측모델

  • 이진호 (한국원자력안전기술원 기계해석실) ;
  • 송명호 (한국원자력안전기술원) ;
  • 최영환 (한국원자력안전기술원) ;
  • 김낙철 (한국원자력안전기술원) ;
  • 문성인 (성균관대학교 기계공학부) ;
  • 김영진 (성균관대학교 기계공학부)
  • Published : 2003.11.05

Abstract

The 40% of wall criterion, which is generally used for the plugging of steam generator tubes, may be applied only to a single crack. In the previous study, a total of 9 failure models were introduced to estimate the local failure of the ligament between cracks and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however, known that parallel axial cracks are more frequently detected during an in-service inspection than collinear axial cracks. The objective of this study is to determine the plastic collapse model which can be applied to the steam generator tube containing two parallel axial through-wall cracks. Nine previously proposed local failure models were selected as the candidates. Subsequently interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed for the determination of the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a plastic zone contact model was selected as an optimum model.

Keywords