• Title/Summary/Keyword: Coliform

Search Result 901, Processing Time 0.028 seconds

Discharge Characteristics of Indicator Microorganisms from Agricultural-Forestry Watersheds (농지-임야에서 발생하는 지표미생물 유출 특성)

  • Kim, Geonha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.153-160
    • /
    • 2008
  • To estimate microbial contaminant loading discharged from diffuse sources, rainfall runoff of six rainfall events were monitored at three study watersheds of forestry and agricultural land use. Monitored indicator microorganism constituents were total coliform (TC), fecal coliform (FC), Escherichia coli (EC), and fecal streptococcus (FS). Soil loss during elevated flow rate caused higher suspended solid concentrations. Indicator microorganism concentrations were closely related with flow rate. TC event mean concentration (EMC) from unpolluted forestry was $5.3{\times}10^3CFU/100ml$, FC EMC was $1.4{\times}10^3CFU/100ml$, EC EMC was $1.1{\times}10^3CFU/100ml$, and FS EMC was $2.9{\times}10^2CFU/100ml$. From a watershed with agricultural-forestry land use, TC EMC was $1.7{\times}10^5CFU/100ml$, FC EMC was $8.5{\times}10^4CFU/100ml$, EC EMC was $8.9{\times}10^4CFU/100ml$, and FS EMC was $3.4{\times}10^4CFU/100ml$. Mixed land use of agricultural-forestry with bigger area, TC EMC was $1.9{\times}10^5CFU/100ml$, FC EMC was $9.6{\times}10^4CFU/100ml$, EC EMC was $7.0{\times}10^4CFU/100ml$, and FS EMC was $5.1{\times}10^4CFU/100ml$.

BACTERIOLOGICAL STUDIES ON MAEKET SEA FOODS 3. Sanitary indicative bacteria in frozen sea foods (시판 수산식품에 대한 세균학적연구 3. 냉동식품의 위생지표세균에 관하여)

  • CHANG Dong-Suck;CHOE Wi-Kyung;CHO Kwon-Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.3
    • /
    • pp.157-165
    • /
    • 1975
  • This experiment was carried out to evaluate the sanitary quality of commercially frozen sea foods. One hundred and sixteen samples in six different items from several refrigeration plant in Busan city were examined from March to December in 1974. In addition, the changes in bacterial density through the process from thawing, round or semifilleted frozen alaska pollack to the finishing as frozen fillet blocks were observed. To evaluate the sanitary quality, sanitary indicative bacteria such as total coliform, fecal coliform, fecal streptococci and enterococci as well as plate counts were determined. From the results, the median value of fecal coliform MPN was 20 per 100 grams of the samples and that of enterococci was 790. The median value of plate counts was $2.2\times10^4$ per gram. The plate counts were not correlated with the number of sanitary indicative bacteria. The results suggest that enterococci could be used advantageously in preference to coliform organisms as indicative bacteria for the evaluation of sanitary quality of frozen sea foods. The plate counts at $20^{\circ}C$ of the samples were 14 times higher than that at $35^{\circ}C$. Geometric mean of total coliform MPN was 310 and that of enterococci was 143. Bacterial density was reduced by fleering. Morethan 50 percent for total coliform MPN and $35^{\circ}C$ plate counts, and about 35 percent for enterococci MPN and $20^{\circ}C$ plate counts were reduced under the contact freezing unit which was generally operated at $-40^{\circ}C$. About fifty-five percent of the samples were negative in fecal coliform test and 10 percent of those were exceeded $1.0\times10^5$ per gram in $35^{\circ}C$ plate counts.

  • PDF

Effect of Electrolyzed Water and Hot-Air-Drying with UV for the Reduction of Microbial Populations of Undaria pinnatifida (전해수 수세, 열풍건조 및 자외선 조사에 의한 미역의 미생물 감소 효과)

  • Bark, Si-Woo;Kim, Koth-Bong-Woo-Ri;Kim, Min-Ji;Kang, Bo-Kyeong;Pak, Won-Min;Kim, Bo-Ram;Ahn, Na-Kyung;Choi, Yeon-Uk;Cho, Young-Je;Ahn, Dong-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study was conducted to investigate the effects of electrolyzed water (EW) and hot-air-drying with ultraviolet light (UV) to reduce coliform bacteria of Undaria pinnatifida (UP). The UP was washed in the order of 15% EW, tap water (TW), and distilled water (DW) under following conditions: 15% EW for 10 min (washing: 1 time), TW for 1 min, and DW for 10 min (washing: 5 times). Viable cells, coliform, and mold counts were at 102-103 CFU/g in untreated samples. After EW treatment, viable cells, coliform, and molds were not detected in whole samples or on the surface of UP. But, after hot-air-drying at 48°C for 48 h, the number of viable cells, coliform, and molds were 101-105 CFU/g. After hot-air-drying at 48°C for 48 h with UV (12-48 h), viable cells, coliform, and molds were not detected in whole samples or on the surface of UP. In respect of color value, there were no significant changes. In sensory evaluation, the UP with hot-air-drying with UV (12 h) had the highest score in overall preference among UV treatment groups. These results suggest that the treatments at 15% EW for 10 min and hot-air-drying at 48°C for 48 h with UV (12 h) were effective to reduce coliform bacteria of the dried Undaria pinnatifida.

Effect of Electrolyzed Water for Reducing Coliform Bacteria on Undaria pinnatifida (전해수 처리에 의한 미역의 대장균군 억제효과)

  • Kim, Bo-Ram;Kim, Koth-Bong-Woo-Ri;Kim, Min-Ji;Kang, Bo-Kyeong;Bark, Si-Woo;Pak, Won-Min;Ahn, Na-Kyung;Choi, Yeon-Uk;Ahn, Dong-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • This study was conducted to investigate the bactericidal activity of electrolyzed water (EW) against coliform bacteria on Undaria pinnatifida (UP). The UP was washed with 15% EW, tap water (TW), and distilled water in the following order: 15% EW for 5 and 10 min (1st to 3rd washing process), TW for 1 min, and distilled water for 10 min (3rd to 5th washing process). The washing processes using 15% EW and distilled water occurred a total of 6 times. The number of viable cells, coliform bacteria, and molds in the untreated sample were in the range of 101 to 103 CFU/g. In the case of the UP with 15% EW for 5 min sample, the viable cell counts were reduced by 1-2 log cycles as compared with the untreated sample. The coliform bacteria were not detected except after the 1st EW washing process. Mold counts were not detected in all treatments. In the UP with 15% EW for 10 min sample, the viable cells, coliform bacteria, and mold counts were not detected. In color, there were no significant differences among samples. In sensory evaluation, the UP treated with 15% EW for 10 min (first washing process) got higher scores for color, aroma, and taste than others. These results suggest that the treatment of 15% EW for 10 min is the most effective way to reduce coliform bacteria of the UP.

Nitrification and Removal of Pathogenic Microorganisms Indicators by an upgraded RBC (생물막공정을 이용한 질산화 및 병원성 미생물의 제거)

  • Bang, Du-Yeon;Chang, In-Soo;Kim, Jee-Hak;Watanabe, Yosimasa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.108-114
    • /
    • 1998
  • Experiments on an upgraded RBC were conducted to investigate its removal efficiencies of $NH_4-N$, coliform group and coliphage in the municipal wastewater treatment. A bench scale RBC, made of stainless mesh media with 5mm high surface protrusions, was fed with settled municipal wastewater containing 13-25mg/l of $NH_4-N$ and 40-75mg/l of TOC at the hydraulic loading of $89l/m^2.d$ and $60l/m^2.d$. It was found that the nitrification effectively occured at bulk liquid TOC concentration of less 10mg/l. The coliform group and coliphage were more than 98% and 90%, respectively.

  • PDF

A View of Soil Microbial Contamination on the Three Sandy Beaches in Busan (부산광역시 세 해수욕장 백사장에서 세균 오염도 조사)

  • Huh, Man-Kyu;Cho, Kyung-Soon
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.3
    • /
    • pp.202-207
    • /
    • 2011
  • Bacterial contamination of beach sand was examined in April, June, July, and August. Twenty four topsoil and subsoil samples were taken from the 1m and 5m points from the coastline in three Busan beaches (Haeundae, Gwanganli, and Songjeong). The 5m points from the coastline showed higher coliform contamination than 1 m points. July showed the highest bacterial contamination on beaches among surveyed months. Coliform contamination in the subsoil was higher than that of the topsoil. The bacterial contamination of 5m points of topsoil and subsoil in June except the Songjeong Beach was higher than those of July and August. We investigated Staphylococcus aureus, Vibrio parahaemolyticus, Vibrio vulnificus, Vibrio cholerae, and Bacillus cereus. Only B. cereus was detected at the beach in August. Although microbiological pollution of the Gwanganli Beach was the highest among three Busan beaches, the degree of contamination was not high compared to those of other countries. However, sandy soil management in public beach for pathogenic microorganisms is needed.

A Study on the Characteristics of Water Quality for Groundwater and Purified Water of Several Schools in Gyeongsangbukdo Province (경상북도지역 학교지하수 및 정수기통과수의 수질특성에 관한 연구)

  • Kim, Suk-Chan;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.575-580
    • /
    • 2011
  • This study characterized water quality of groundwater and purified water used for drinking water in 30 schools in Gyeongsangbukdo Province. The results of the study showed that 43% of groundwater and 45% of purified water were not suitable for drinking. Among them, microbial contaminations were the most serious problem. In raw groundwater, the exceeding rates of total colony counts was the highest in August (53.6%). Purified water samples showed higher rate of exceeding drinking water standard for total colony counts while showing lower rate of exceeding drinking water standard for total coliforms and fecal coliforms in March and August. Overall, proper managements for microbial contaminations are required for both groundwater and purified water. Furthermore, special attention should toward students not to drink water when groundwater or purified water exceeds the drinking water quality standard.

Determination of Enteric Bacteria at Microbiologically Risky Points by Multiplex Polymerase Chain Reaction

  • Mahir Gulec;Bilal Bakir;Recai Ogur;Tekbas, Omer-Faruk
    • Journal of Microbiology
    • /
    • v.40 no.4
    • /
    • pp.327-330
    • /
    • 2002
  • The purpose of this research was to test multiplex polymerase chain reaction in investigating the microbiological quality of the risky surfaces in social living places of a military base where over 15 thousand people live together. In 22 samples of 99, there were no bacteria. Only four of the samples contained Shigella, and one of them contained Salmonella, but 77 of the samples contained thermotolerant coliform organisms. There was no statistically significant difference among the microbiological quality of different sites and different equipment surfaces (p>0.05).

Efficiency Comparison between Chlorine and Chlorine Dioxide to Control Bacterial Regrowth in Water Distribution System

  • Lee, Yoon-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.282-291
    • /
    • 2006
  • This study investigated the inactivation of the total coliform, an indicator organism in chlorine and chlorine in order to control microbial regrowth for water distribution systems and select an appropriate disinfection strategy for drinking water systems. The disinfection effects of chlorine and chlorine dioxide with regard to the dosage of disinfectant, contact time and DOC was investigated experimentally. In spite of the consistency of chlorine residuals at approximately 0.2 mg/l, bacteria regrowth was detected in the distribution system and it was confirmed by the scanning electron microscope results. The influence of organic carbon change on the killing effect of chlorine dioxide was strong.