• Title/Summary/Keyword: Cold distribution center

Search Result 123, Processing Time 0.027 seconds

Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates (다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가)

  • Lim, T.W.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF

Lyα Radiative Transfer and The Wouthuysen-Field effect

  • Seon, Kwang-Il;Kim, Chang-Goo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.43.1-43.1
    • /
    • 2017
  • A three-dimensional (3D) $Ly{\alpha}$ radiative transfer code is developed to study the Wouthuysen-Field effect, which couples the 21 cm spin temperature of neutral hydrogen and the $Ly{\alpha}$ radiation field, and the escape fraction of $Ly{\alpha}$ from galaxies. The Monte Carlo code is capable of treating arbitrary 3D distributions of $Ly{\alpha}$ source, neutral hydrogen and dust densities, gas temperature, and velocity field. It is demonstrated that the resonance-line profile at the center approaches to the Boltzmann distribution with the gas temperature. A plane-parallel ISM model, which is appropriate for the neutral ISM of our Galaxy, is used to calculate the $Ly{\alpha}$ radiation field strength as a function of height above the galactic plane. We also use a two-phase, clumpy medium model which is composed of the cold and warm neutral media (WNM). It is found that the $Ly{\alpha}$ radiation field is strong enough to thermalize the 21 cm spin temperature in the WNM to the gas kinetic temperature. The escape fraction of $Ly{\alpha}$ is found to be a few percent, which is consistent with the $Ly{\alpha}$ observations of our Galaxy and external galaxies.

  • PDF

A Study on Thermo-flow Characteristics Analysis of Electric Water Pump (전동 워터펌프의 열유동 특성 해석에 관한 연구)

  • Kim, Sung-Chul;Song, Hyeong-Geun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.95-101
    • /
    • 2012
  • An electric water pump for engine cooling system has an advantage which particularly in the cold start, the use of the electric water pump saves fuel and leads to a corresponding reduction in emissions. The canned type electric water pump without mechanical sealing elements was selected to meet the requirements for operational reliability and life. However, the electric water pump for internal combustion engine generates much more heat loss than for hybrid electric vehicle since it is operated by the electric power of high current and low voltage. In this study, the fluid flow and thermal characteristics of the canned type electric water pump as an inverter integrated water pump has been investigated under the effects of heat generation. The analysis conditions such as outdoor air temperature of $125^{\circ}C$, water pump speed of 6000 rpm, coolant temperature of $106^{\circ}C$ and coolant flow rate of 120 L/min was used as a standard condition. Therefore, flow fields and temperature distribution inside the water pump were obtained. Also, we checked the feasibility of the canned type for the electric water pump in comparison with the mechanical seal type.

Deformation Characteristics of Compound Curved Plate Bending by Asymmetric Rollers (상하 비대칭 롤러를 이용한 이중곡면 성형의 변형특성에 대한 연구)

  • 최양렬;신종계
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.38-43
    • /
    • 2002
  • Die-less forming is a cold forming process which is to bend thick flat plates into compound curved plates using two asymmetric rollers. This forming method has several advantages compared with line heating which is widely used to fabricate compound curved pieces in shipyards. The die-less forming, however, has scarcely been studied. Even the deformation mechanism in this forming process has not been understood clearly. So, in this paper, the deformation characteristics of die-less forming is investigated analytically and numerically. for the analytic investigation, slab method based on equilibrium equation is applied. And the mechanism of curvature generation is derived for the asymmetry in roller applied. And three dimensional numerical analyses are performed with realistic modeling of interactions between the rollers and work-piece using finite element program, ABAQUS. It is shown that curvature generation is mainly due to the difference of normal positive strain distribution between the top and bottom surface of the work-piece. And a convex-type curved plate is formed if the center region of the work-piece is rolled with asymmetric rollers of which the lower is larger than the upper in diameter.

An Experimental Study on the Swirling Flow Field in the Tangentially Fired Furnace (접선식 배치로내의 선회유동장에 관한 실험적 연구)

  • ;;;Yoon, S. H.;Sim, J. K.;Song, H. B.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3003-3013
    • /
    • 1995
  • The characteristics of the flow field in the tangentially fired furnace are presented. Experiments are conducted in the simplified cold type isothermal flow model. In the measurement of flow field, a hot wire anemometer is used. The hot wire was calibrated by lookup table method. The mean velocity field and turbulence characteristics are showed with changing the nozzle angle. In the center of the model, the low speed, unstable flow region is formed. The size and position of these regions are varied with changing the nozzle angle. It can be used as fundamental data in the design of the large furnace. From the experimental results, various turbulent characteristics of swirling flow field is obtained. And the entrainment mechanism of the jet flow field is described from the distribution of the skewness and the flatness. It can be used the raw data of approximate calculation and turbulent modelling.

Effect of Manufacturing Conditions on the Anisotropic Dimensional Change of STD11 Tool Steel during Heat Treatment (STD11 공구강의 열처리 치수변화 이방성에 미치는 제조 조건의 영향)

  • Hong, Ki-Jung;Song, Jin-Hwa;Chung, In-Sang
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.1
    • /
    • pp.13-22
    • /
    • 2012
  • Forged and flat-bar rolled STD11 tool steel shows anisotropic dimensional change during heat treatment. The dimensional change in the rolling direction is larger than that in the transverse direction. The cause of the anisotropic dimensional change is that the steel is anisotropic in composition, microstructure and other properties. The decrease of anisotropic distortion in tool steel is important for making better precision cold working dies. In this study, the effect of ingot weight and hot rolling reduction ratio on the anisotropic dimensional change of STD11 during heat treatment has been studied. Dimensional change was evaluated by simulating a real heat treatment process, including gas quenching and tempering. Experimental results showed that all the rolled flat-bar products had anisotropic distortion to some degree, but the anisotropic distortion was reduced as hot rolling ratio increased. Ingot weight had a little effect on anisotropic distortion. Microstructural observation showed that the anisotropic dimensional change of STD11 tool steel was closely related to the amount, shape and distribution of coarse carbides.

A Survey on Actual Wearing Condition and Satisfaction of Functional Inner Winter Uniform for Male Soldiers in Korea (한국 남자 군인 기능성 방한복 내피 개발을 위한 실태 및 만족도 조사)

  • Kim, Youn Joo;Kim, Seonyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.910-926
    • /
    • 2022
  • Suitability for the human body, freedom to move and thermal insulation are important design considerations in military clothing. This study investigates the performance and wearer-satisfaction of the functional inner winter uniform currently used in Korea; it is hoped that our data can inform the development of a future version. Interviews were conducted, in which the participants suggested various improvements. The uniforms were mainly worn for guard duty or as daily attire in cold weather. The participants chose how many layers to wear according to the current situation, rather than sticking to the layering recommended in the manual. Layering choices did not significantly affect combat efficiency but were found to affect wearers' comfort. Wearers' satisfaction was found to depend on the convenience of the clothing, whether it was in the appropriate size, freedom to move and thermal insulation. Also, this study suggests a problem with the current size system, as the analysis of size distribution, across all sizes, the range of current production is insufficient to cover the demand.

Investigation of Internal Temperature Distribution in Domestic Refrigerators and Freezers (가정용 식품 냉장고와 냉동고의 내부 온도 분포 실태 조사)

  • Dong Bin Lee;Jong Eok Kim;Ja Yeong Lee;Sang Gu Kim;Sang Yun Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.373-380
    • /
    • 2023
  • This study surveyed and compared the temperature distribution in domestic refrigerators and freezers used in Korea to determine whether temperature varied according to the location of food storage. We selected 50 people to collect temperature data; among them, 25 measured the temperature of refrigerators, while the remaining measured the temperature of freezers. Consequently, the lowest and highest temperatures measured in domestic refrigerators were found to be -8.2℃ and 15.8℃, respectively, with an average temperature of 3.73℃. The temperature distribution based on internal location was: 5.06±1.69℃ for the door storage compartment, 4.18±1.19℃ for the inside wall surface, and 3.41±1.36℃ for the inner storage box. Significant temperature differences between the top and bottom were only identified at the door storage compartment (P<0.01). Further, the minimum and maximum temperatures measured in the freezer was -30.3℃ and 0.7℃, respectively, with an average temperature of -17.95℃. The temperature distribution based on location was: -17.19±1.68℃ for the door storage compartment, -17.81±1.07℃ for the inside wall surface, and -18.78±1.72℃ for the inside storage box. The results were similar to that of the refrigerator, with the lowest temperature in the inside storage box, and a significant temperature difference between the top and bottom noted only at the door (P<0.01). The maximum temperature difference (between locations) within the refrigerator and freezer was found to be 2.18 and 2.02℃, respectively. In conclusion, the temperature in the entire space was not constant; there were significant deviations at different storage locations. Therefore, public authorities should actively advise customers on the recommended storage locations for each food type. People will benefit from awareness about storage management, including avoiding storage of temperature-sensitive foods in door compartment.

The Analysis of Spatial Distribution of Gifted Education Units in Seoul (서울시 영재교육기관의 공간적 분포특성 분석)

  • Kim, Sungyeun;Lee, Seon-Young
    • Journal of Gifted/Talented Education
    • /
    • v.25 no.5
    • /
    • pp.711-729
    • /
    • 2015
  • The purposes of this study are to derive the regions in Seoul that lack gifted education units by analyzing the spatial distribution of the units and to investigate the factors related to the unit locations. The gifted education units are divided into the three following types: the first type is a gifted class at a school, the second type is a gifted education center at a provincial office of education, and the third type is a gifted education center at a university. The results of using a GIS-based spatial analysis were as follows. First, a buffering analysis showed that even though there were gifted educational blind spots in Jongno-gu and in parts of the outskirts of Seoul, the spatial distribution of gifted education units in Seoul seemed homogeneous because they were too small. Second, a special quotient analysis showed that there was a hub unit of gifted education in Guro-gu. Third, an analysis of local Moran's Index showed that Jung-gu was a cold spot and Songa-gu was a hot spot. Fourth, a correlation analysis investigated that the number of gifted education units had generally no statistically significant relationship with economic factors. These results will help to improve the efficiency and equity of the management of the gifted education units in Seoul that will be established or expanded in the future.

Structure of the Phytoplanktonic communities in Jeju Strait and Northern East China Sea and Dinoflagellate Blooms in Spring 2004: Analysis of Photosynthetic Pigments (봄철 제주해협과 동중국해 북부해역에서 식물플랑크톤의 광합성 색소분석을 이용한 군집 분포 특성과 dinoflagellate 적조)

  • Park, Mi-Ok;Kang, Sung-Won;Lee, Chung-Il;Choi, Tae-Seob;Lantoine, Francois
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.1
    • /
    • pp.27-41
    • /
    • 2008
  • Distribution characteristics of phytoplankton community were investigated by HPLC and flow cytometry in Jeju Strait and the Northern East China Sea (NECS) in May 2004, in order to understand the relationship between physical environmental factors and distribution pattern of phytoplankton communities. Based on temperature and salinity data, three distinct water masses were identified; warm and saline Tsushima Warm Current (TWC), which is flowing from northwest of Jeju Island, warm and low saline water at the center of Jeju Strait, which is originated from China Coastal Water (CCW) and relatively cold and high saline water originated from Yellow Sea at the bottom of the Jeju Strait. At Jeju Strait, less saline water (<33 psu) of 15 km width occupied surface layer up to 20 m which located at 20 km offshore and strong thermal front between warm and saline water and cold and less saline water was found in the middle of the Jeju Strait. Vertical transect of temperature and salinity at the NECS also showed that low saline (<33 psu) water occupied the upper 20 m layer and cold and saline water was present at the eastern part. Chl a was measured as $0.06{\sim}3.07\;{\mu}g/L$. Spring bloom of phytoplankton was recognized by the high concentrations of Chl a at the low saline water masses influenced by the CCW and subsurface chlorophyll maximum layer appeared between $20{\sim}30\;m$ depth, which was at thermocline depth or below. Abundances of Synechococcus and picoeukaryote were $0.2{\sim}9.5{\times}10^4\;cells/mL$ and $0.43{\sim}4.3{\times}10^4\;cells/mL$, respectively. Dinoflagellate, diatom and prymnesiophyte were major groups and minor groups were chlorophyte+prasinophyte, chrysophyte, cryptophyte and cyanophyte. Especially high abundance of dinoflagellate was identified by high concentration (>1\;{\mu}g/L$) of peridinin at the bottom of the thermocline, which showed an outbreak of red tide by high density of dinoflagellates. Abundances of picoeukaryote in Jeju Strait were about $5{\sim}10$ times higher than abundance measured in Kuroshio water and showed a good correlation with Chl b (Pras+Viola), which implies the most of population of picoeukaryote was composed of prasinophytes. Prochlorococcus was not detected at all, which suggests that Kuroshio Current did not directly influenced on the study area. Based on the strong negative correlations between biomass of phytoplankton (Chl a) and temperature+salinity, the primary production and biomass of phytoplankton in the study area were controlled by the nutrients supply from CCW.