• 제목/요약/키워드: Cold Air

검색결과 1,226건 처리시간 0.027초

혹한지역 기초 콘크리트의 내구성 향상을 위한 실험 연구 (An Experimental Study on the Improvement of Durability for the Foundation Concrete under Cold Weather Condition)

  • 우상균;송영철;김경민;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.645-650
    • /
    • 2003
  • The purpose of this study is to provide the optimum mix design of cold weather concrete to be placed at the foundation structures in substation. The basic performance tests including slump and slump flow, air content, compressive strength and freezing & thawing resistance were conducted for cold weather concrete by varying with W/C ratios such as 40%, 50% and 60% and air contents such as 3%, 4%, 5% and 6%. The effect on durability of concrete corresponding to the increasing amount of air content and W/C ratio was evaluated and the optimum mix design was recommended. From this study, the concrete mix design containing 6% of air content and 45% of W/C ratio is recommended for the foundation concrete of substation.

  • PDF

2차 공기분사 및 냉각수제어에 의한 SI 엔진의 탄화수소 배기저감 (SI Engine Hydrocarbon Emissions Reduction with Secondary Air Injection and Coolant Control)

  • 박기수;조영진;박심수
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.51-58
    • /
    • 2000
  • It is well known that the majority of the emissions measured from vehicle exhaust in the US Federal Test Procedure(FTP-75) are emitted during the first 60 seconds. This paper describes an experimental study on SI engine emissions reduction after cold start with interval secondary air injection and coolant control. Secondary air injection after cold start to reduce exhaust emissions causes an exothermic reaction at the exhaust port and gives sufficient air to the catalyst. For that reason engine-out emissions oxidized in the exhaust port and the rapid heating of a catalytic converter after cold start with CSAI and ISAI are estimated. The influence of the coolant temperature on SI engine emissions has been estimated. In the present studycoolant control of the cylinder head tempeature is used to investigate the effect of coolant temperature on SI engine emissions. The results show that engine-out hydrocarbon and carbon monoxide emissions are considerably reduced with interval secondary air injection and coolant control.

  • PDF

CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구 (A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store)

  • 조성우;박민용;임영빈
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.

액화천연가스의 냉열을 이용한 가스터빈의 성능향상 (Improvement of Gas Turbine Performance Using LNG Cold Energy)

  • 김동섭;노승탁;이우일;최만수;고상근
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

국내의 냉동공조기기 및 맹장설비 동향분석 (Trend of Refrigeration and Air-Conditioning Related Product and Facility in Korea)

  • 오후규;김병철;박기원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.585-590
    • /
    • 2005
  • It can be said that refrigeration and air-conditioning technology in Korea dates back to the ancient Shilla dynasty, all the way up to the Sokkuram(700s) and Seokbinggo(1700s). But modem refrigeration and air-conditioning technology was first developed in and introduced to Korea in the 1960s with the modernization of Korea. Today it is at a level which meets that of advanced countries in both the industrial and domestic fields. 62 million units of refrigeration and air-conditioning machinery and equipment were produced in 2003, worth a total of 7.7 trillion won(about 7.7 thousand million US$). As of 2003, there were about 700 companies that owned cold storage / freezing / refrigeration facilities, with cold storage capacity of about 2 million ton and capacity per company of about 3 thousand ton. This facilities most are continuously expanding and automatizing their facilities.

  • PDF

건조방법에 따른 삼투처리 단호박의 품질 특성 (Quality Characteristics of Osmotic Dehydrated Sweet Pumpkin by Different Drying Methods)

  • 홍주헌;이원영
    • 한국식품영양과학회지
    • /
    • 제33권9호
    • /
    • pp.1573-1579
    • /
    • 2004
  • 단호박을 이용하여 새로운 가공제품을 개발하고자 여러가지 잇점을 줄 수 있는 삼투건조를 최적조건에서 처리하고 산업적으로 많이 사용되고 있는 열풍, 진공건조와 새로운 건조방법의 적용을 위해 선정한 냉풍건조를 행한 후 품질특성을 비교 평가하였다. 삼투처리 후 열풍, 진공, 냉풍건조된 단호박의 수분함량은 sucrose로 삼투처리한 경우가 모든 건조 방법에서 glucose 처리구보다 낮았으며, 건조방법에 따른 비타민 C의 함량은 glucose로 삼투처리 후 냉풍건조한 경우가 35.69 ㎎/100 g으로 가장 높게 측정되었다. 전반적으로 침지 용액에 따른 L, a, b값은 유사한 경향이었으며, 냉풍건조가 색도변화가 가장 작게 일어나 생단호박의 색상과 유사하였다. 건조 단호박의 표면구조는 삼투용액과 건조방법에 따라 상이하였는데, 삼투처리 후 냉풍건조된 단호박을 제외하고 열풍 및 진공건조된 단호박의 조직 손상이 크게 나타났다. 건조방법 및 건조시간에 따른 수분함량과 비타민 C함량을 살펴보면 수분함량의 경우 건조효율성을 고려할 때 sucrose로 삼투처리 후 진공건조한 단호박이 가장 우수하였으나, 비타민 C함량에서는 glucose로 삼투처리 후 냉풍건조한 단호박이 가장 양호하였다. 삼투용액에 따른 건조방법별 건조속도는 sucrose로 삼투처리한 단호박의 건조속도가 glucose 처리구보다 빠름을 알 수 있었다.

CPW PHEMT의 에어브리지에 의한 이득 감소 현상에 대한 연구 (The study of RF gain reduction due to air-bridge for CPW PHEMT's)

  • 임병옥;강태신;이복형;이문교;이진구
    • 대한전자공학회논문지SD
    • /
    • 제40권12호
    • /
    • pp.10-16
    • /
    • 2003
  • 에어브리지의 기생 커패시턴스의 영향을 분석하기 위해 CPW PHEMT의 기존 cold-FET 회로모델에 게이트-에어브리지의 기생 커패시턴스(C/sub ag/)차 드레인-에어브리지의 기생 커패시턴스(C/sub ad/)를 더해주었다. 또한 제안된 모델을 사용하여 소자의 parameter들을 추출하여, 그 존재를 확인하였다. 본 논문에서는 에어브리지에 의해 생성되는 기생 커패시턴스의 영향을 연구하기 위해 에어브리지의 여러 연결방법을 CPW PHEMT 제작에 접목시켰다. 또한 핀치오프상태의 cold-FET에 대한 개선된 등가회로 모델을 제시하여 에어브리지에 의한 기생 커패시턴스가 소자 특성에 어떤 영향을 주는 가를 분석하였다. 제작된 CPW PHEMT의 측정 결과로부터, 기생 커패시턴스 C/sub ag/와 C/sub ad/가 소자의 S/sub 21/ 이득을 감소시키는 중요한 요소임을 확인하였다.

대구시 열대야 대응 구역 설정을 위한 야간 찬공기 유동성 분석 (Analysis of Nocturnal Cold Air Flow Characteristics for Setting of Tropical Night Response Zone in Daegu)

  • 서보용;이상범;권순범;차재규;정응호
    • 한국지리정보학회지
    • /
    • 제23권3호
    • /
    • pp.220-235
    • /
    • 2020
  • 도시에서의 폭염발생은 기본적으로 지구온난화에 영향을 받으나, 도시에서 발생하는 인공열 배출과 열축적이 큰 토지피복의 영향으로 더욱 가중된다. 특히 도시폭염의 영향은 야간 열대야 발생에도 직접적 영향을 준다. 그러나 기본적으로 주간의 폭염대응에 비해 열대야 대응수단 선택은 매우 제한적이다. 본 연구에서는 대구시를 대상으로 열대야 대응 방안으로 야간 찬공기 유동 특성을 분석하고 이의 공간적 활용가능성을 제시하고자 하였다. 연구방법은 찬공기 유동 분석 프로그램인 KLAM_21을 활용하여 대구시의 찬공기 유동의 공간적 특성인 찬공기 높이 및 유동범위와 유속 및 유동방향을 정량적으로 분석하였다. 분석결과 대구시 주변산지에서의 찬공기 생성, 유동은 매우 활발하나 열대야 발생지역인 도심지역으로 유입이 제한적인 것으로 나타났다. 그러나 일부 시가지에서는 주변산지로부터 유입되는 찬공기 유동성이 매우 활발하여 열대야 대응에 매우 효과적인 공간적 조건을 가지고 있는 것으로 나타났다. 이러한 공간적 조건을 도시계획적 차원에서 활용하면 열대야 대응방안 개발에 매우 유용할 것으로 판단된다.