• Title/Summary/Keyword: Coefficient masks

Search Result 10, Processing Time 0.064 seconds

Edge Detection Method using Modified Coefficient Masks (변형된 계수 마스크를 이용한 에지 검출 방법)

  • Lee, Chang-Young;Chung, Suk-Moon;Kim, Nam-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.218-223
    • /
    • 2013
  • The performances of previous edge detection methods such as Sobel, Prewitt, and LoG(Laplacian of Gaussian) are insufficient for images degraded in AWGN(additive white Gaussian noise). Therefore, in this paper, we proposed an edge detection algorithm using a modified coefficient masks with gradient masks and distance weight mask. In order to confirm and verify the performance of the proposed algorithm, we simulated and compared proposed algorithm to conventional methods on various standard images added AWGN with a standard deviation ${\sigma}$=15, 30 and proposed algorithm shows superior edge detection characteristics in processed images.

The Effect of Grain Size and Film Thickness on the Thermal Expansion Coefficient of Copper and Silver Thin Films (구리와 은 박막의 열팽창계수에 미치는 결정립 크기와 박막 두께의 영향)

  • Hwang, Seulgi;Kim, Youngman
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1064-1069
    • /
    • 2010
  • Thin films have been used in a large variety of technological applications such as solar cells, optical memories, photolithographic masks, protective coatings, and electronic contacts. If thin films experience frequent temperature changes, thermal stresses are generated due to the difference in the coefficient of thermal expansion between the film and substrate. Thermal stresses may lead to damage or deformation in thin film used in electronic devices and micro-machined structures. Thus, knowledge of the thermomechanical properties of thin films, such as the coefficient of thermal expansion, is an important issue in determining the stability and reliability of the thin film devices. In this study, thermal cycling of Cu and Ag thin films with various microstructures was employed to assess the coefficient of thermal expansion of the films. The result revealed that the coefficient of thermal expansion (CTE) of the Cu and Ag thin films increased with an increasing grain size. However, the effect of film thickness on the CTE did not show a remarkable difference.

Quantification of Gadolinium Concentration Using GRE and UTE Sequences

  • Park, So Hee;Nam, Yoonho;Choi, Hyun Seok;Woo, Seung Tae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.171-176
    • /
    • 2017
  • Purpose: To compare different MR sequences for quantification of gadolinium concentration. Materials and Methods: Gadolinium contrast agents were diluted into 36 different concentrations. They were scanned using gradient echo (GRE) and ultrashort echo time (UTE) and R1, $R2^*$ and phase values were estimated from collected data. For analysis, ROI masks were made for each concentration and then ROI value was measured by mean and standard deviation from the estimated quantitative maps. Correlation analysis was performed and correlation coefficient was calculated. Results: Using GRE sequence, R1 showed a strong linear correlation at concentrations of 10 mM or less, and $R2^*$ showed a strong linear correlation between 10 to 100 mM. The phase of GRE generally exhibited a negative linear relationship for concentrations of 100 mM or less. In the case of UTE, the phase had a strong negative linear relationship at concentrations 100 mM or above. Conclusion: R1, which was calculated by conventional GRE, showed a high performance of quantification for lower concentrations, with a correlation coefficient of 0.966 (10 mM or less). $R2^*$ showed stronger potential for higher concentrations with a correlation coefficient of 0.984 (10 to 100 mM), and UTE phase showed potential for even higher concentrations with a correlation coefficient of 0.992 (100 mM or above).

Experimental Verification of Analysis Model of the Shadow Mask with Damping Wires (댐핑 와이어를 갖는 새도우 마스크의 해석모델에 대한 실험적 검증)

  • 김성대;김원진;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.460-465
    • /
    • 2002
  • The nonlinear vibration of the CRT shadow mask is analyzed in consideration of the V-shaped tension distribution and the effect of wire impact damping. The reduced order FEM model of the shadow mask is obtained from dynamic condensation for the mass and stiffness matrices. Damping wire is modeled using the lumped parameter method to effectively describe its contact interactions with the shadow mask. The nonlinear contact-impact model is composed of spring and damper elements, of which parameters are determined from the Hertzian contact theory and the restitution coefficient, respectively. The analysis model of the shadow mask with damping wires is experimentally verified through impact tests of shadow masks performed in a vacuum chamber. Using the validated analysis model of the shadow mask with damping wires, the‘design of experiments’technique is applied to search fur the optimal damping wire configuration so that the vibration attenuation of the shadow mask is maximized.

  • PDF

Experimental Verification of Analysis Model of the Shadow Mask with Damping Wires (댐핑 와이어를 갖는 새도우 마스크의 해석모델에 대한 실험적 검증)

  • 김성대;김원진;이종원
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.9
    • /
    • pp.731-737
    • /
    • 2002
  • Nonlinear vibration of the CRT shadow mask with impact damping wires is analyzed in consideration of the mask tension distribution and the effect of wire impact damping. A reduced order FEM model of the shadow mask is obtained from dynamic condensation of the mass and stiffness matrices, and damping wire is modeled using the lumped parameter method to effectively describe its contact interactions with the shadow mask. The nonlinear contact-impact model is composed of spring and damper elements, of which parameters are determined from the Hertzian contact theory and the restitution coefficient, respectively. The analysis model of the shadow mask with damping wires is experimentally verified through impact tests of shadow masks performed in a vacuum chamber.

Joint-transform Correlator Multiple-image Encryption System Based on Quick-response Code Key

  • Chen, Qi;Shen, Xueju;Cheng, Yue;Huang, Fuyu;Lin, Chao;Liu, HeXiong
    • Current Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.320-328
    • /
    • 2019
  • A method for joint-transform correlator (JTC) multiple-image encryption based on a quick-response (QR) code key is proposed. The QR codes converted from different texts are used as key masks to encrypt and decrypt multiple images. Not only can Chinese text and English text be used as key text, but also symbols can be used. With this method, users have no need to transmit the whole key mask; they only need to transmit the text that is used to generate the key. The correlation coefficient is introduced to evaluate the decryption performance of our proposed cryptosystem, and we explore the sensitivity of the key mask and the capability for multiple-image encryption. Robustness analysis is also conducted in this paper. Computer simulations and experimental results verify the correctness of this method.

Aerosol Indirect Effect Studies derived from the Ground-based Remote Sensings (지상원격탐사를 이용한 에어러솔 간접효과 연구)

  • Kim Byung-Gon;Kwon Tae-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.235-247
    • /
    • 2006
  • Aerosol indirect radiative forcing of climate change is considered the most uncertain forcing of climate change over the industrial period, despite numerous studies demonstrating such modification of cloud properties and several studies quantifying resulting changes in shortwave radiative fluxes. Detection of this effect is made difficult by the large inherent variability in cloud liquid water path (LWP): the dominant controlling influence of LWP on optical depth and albedo masks any aerosol influences. Here we have used ground-based remote sensing of cloud optical depth (${\tau}_c$) by narrowband radiometry and LWP by microwave radiometry to determine the dependence of optical depth on LWP, thereby permitting examination of aerosol influence. The method is limited to complete overcast conditions with liquid-phase single layer clouds, as determined mainly by millimeter wave cloud radar. The results demonstrate substantial (factor of 2) day-to-day variation in cloud drop effective radius at the ARM Southern Great Plains site that is weakly associated with variation in aerosol loading as characterized by light-scattering coefficient at the surface. The substantial scatter suggests the importance of meteorological influences on cloud drop size as well, which should be analyzed in the further intensive studies. Meanwhile, it is notable that the decrease in cloud drop effective radius results in marked increase in cloud albedo.

The Faulty Detection of COG Using Image Registration (이미지 정합을 이용한 COG 불량 검출)

  • JOO KISEE;Jeong Jong-Myeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.308-314
    • /
    • 2006
  • A line scan camera is applied to enhance COG(Chip On Glass) inspection accuracy to be measured a few micro unit. The foreign substance detection among various faulty factors has been the most difficult technology in the faulty automatic inspection step since COG pattern is very miniature and complexity. In this paper, we proposed two step area segmentation template matching method to increase matching speed. Futhermore to detect foreign substance(such as dust, scratch) with a few micro unit, the new method using gradient mask and AND operation was proposed. The proposed 2 step template matching method increased 0.3 - 0.4 second matching speed compared with conventional correlation coefficient. Also, the proposed foreign substance applied masks enhanced $5-8\%$ faulty detection rate compared with conventional no mask application method.

Exposure and Risk Assessment of Operators to Insecticide Acetamiprid during Treatment on Apple Orchard

  • Kim, Eunhye;Moon, Joon-Kwan;Lee, Hyeri;Kim, Suhee;Hwang, Yon-Jin;Kim, Byung-Joon;Lee, Jinbeum;Lee, Dong-Hyuk;Kim, Jeong-Han
    • Horticultural Science & Technology
    • /
    • v.31 no.2
    • /
    • pp.239-245
    • /
    • 2013
  • Occupational exposure and risk assessment were conducted to evaluate the safety of operators when insecticide acetamiprid was applied to apple orchard using a speed sprayer. Dermal patches, cotton gloves, socks, and masks were used to monitor the dermal exposure, and personal air pump with solid sorbent was used to measure the potential inhalation exposure. In validation to analytical methods, the limit of detection and limit of quantitation were 0.25 ng and 1 ng, respectively. Good reproducibility (coefficient variation < 4%), linearity (coefficient determination > 0.999), and recovery (85.3-118.2%) were obtained. Trapping efficiency of solid sorbent was 96.4% while breakthrough did not occur. Only hand exposure was measured on the gloves during mixing/loading to give $33-1,132{\mu}g$. Exposure amount of operator 3 among 4 workers was noticeably high. The total volumes of spray liquid for operators were $535-1,235mL{\cdot}h^{-1}$, corresponding to 0.03-0.08% of the applied spray solution. Highest contaminated parts of body were thighs, chest, and lower legs. The inhalation exposure ratio to the total application amount was significantly low. However, wind seemed to affect the inhalation exposure of operator. For risk assessment, margin of safety was calculated by the application of cloth and dermal penetration rate to obtain values of much larger than 1 in all cases. Therefore, health risk of operators during treatment of acetamiprid in apple orchard could be of least possibility.

Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles (시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교)

  • Seo, Hyekyung;Jang, Hoyeong;Shim, Sua;Kim, Huiju;Han, Donhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.