• 제목/요약/키워드: Coefficient analysis

검색결과 10,656건 처리시간 0.036초

단순회귀분석에 의한 토층지반의 투수계수 산정모델 (Estimation model of coefficient of permeability of soil layer using linear regression analysis)

  • 이문세;김경수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.1043-1052
    • /
    • 2009
  • To derive easily the coefficient of permeability from several other soil properties, the estimation model of coefficient of permeability was proposed using linear regression analysis. The coefficient of permeability is one of the major factors to evaluate the soil characteristics. The study area is located in Kangwon-do Pyeongchang-gun Jinbu-Myeon. Soil samples of 45 spots were taken from the study area and various soil tests were carried out in laboratory. After selecting the soil factor influenced by the coefficient of permeability through the correlation analysis, the estimation model of coefficient of permeability was developed using the linear regression analysis between the selected soil factor and the coefficient of permeability from permeability test. Also, the estimation model of coefficient of permeability was compared with the results from permeability test and empirical equation, and the suitability of proposed model was proved. As the result of correlation analysis between various soil factors and the coefficient of permeability using SPSS(statistical package for the social sciences), the largest influence factor of coefficient of permeability were the effective grain size, porosity and dry unit weight. The coefficient of permeability calculated from the proposed model was similar to that resulted from permeability test. Therefore, the proposed model can be used in case of estimating the coefficient of permeability at the same soil condition like study area.

  • PDF

온간단조 공정의 계면열전달계수 (Contact Heat Transfer Coefficient for Finite Element Analysis in Warm Forging Processes)

  • 강종훈;고병호;제진수;강성수
    • 소성∙가공
    • /
    • 제15권3호
    • /
    • pp.183-188
    • /
    • 2006
  • Heat transfer coefficients have great influence on finite element analysis results in elevated temperature forging processes. Experimentally calculated contact heat transfer coefficient is not suitable for one-time finite element analysis because analyzed temperature will be appeared to be too low. To get contact heat transfer coefficient for one-time finite element analysis, tool temperature in operation was measured with thermocouple and repeated finite element analysis was performed with experimentally calculated contact and cooling heat transfer coefficient. Surface temperature of active tool was obtained comparing measurement and analysis results. Contact heat transfer coefficient for one-time finite element analysis was achieved analyzing surface temperature between repeated finite element analysis and one-time finite element analysis results.

영향계수의 전달에 의한 2중 원통형 셸의 자유진동해석 (Free Vibration Analysis of Double Cylindrical Shells Using Transfer of Influence Coefficent)

  • 최명수;여동준
    • 동력기계공학회지
    • /
    • 제21권5호
    • /
    • pp.48-54
    • /
    • 2017
  • The transfer influence coefficient method which is an vibration analysis algorithm based on the transfer of influence coefficient is applied to the free vibration analysis of double cylindrical shells. After the computational programs for the free vibration analysis of double cylindrical shells were made using the transfer influence coefficient method and the transfer matrix method, we compared the results using the transfer influence coefficient method with those by the transfer matrix method. The transfer influence coefficient method provided the good computational results in the free vibration analysis of double cylindrical shells. In particular, The results of the transfer influence coefficient method are superior to those of the transfer matrix method when the stiffness of internal springs connecting a inside cylindrical shell and a outside cylindrical shell is very large.

Research on heat transfer coefficient of supercritical water based on factorial and correspondence analysis

  • Xiang, Feng;Tao, Zhou;Jialei, Zhang;Boya, Zhang;Dongliang, Ma
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1409-1416
    • /
    • 2020
  • The study of heat transfer coefficient of supercritical water plays an important role in improving the heat transfer efficiency of the reactor. Taking the supercritical natural circulation experimental bench as the research object, the effects of power, flow, pipe diameter and mainstream temperature on the heat transfer coefficient of supercritical water were studied. At the same time, the experimental data of Chen Yuzhou's supercritical water heat transfer coefficient was collected. Through the factorial design method, the influence of different factors and their interactions on the heat transfer coefficient of supercritical water is analyzed. Through the corresponding analysis method, the influencing factors of different levels of heat transfer coefficient are analyzed. It can be found: Except for the effects of flow rate, power, power-temperature and temperature, the influence of other factors on the natural circulation heat transfer coefficient of supercritical water is negligible. When the heat transfer coefficient is low, it is mainly affected by the pipe diameter. As the heat transfer coefficient is further increased, it is mainly affected by temperature and power. When the heat transfer coefficient is at a large level, the influence of the flow rate is the largest at this time.

ROWECELL시험에 의한 해성점토의 압밀계수에 대한 연구 (Study on the Coefficient of Consolidation of Marine Clay by Rowecell Consolidation Test)

  • 김종국;차영일;김혁기;김영웅
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.725-732
    • /
    • 2003
  • It was achieved that Rowecell test for this undisturbed sample was picked by Block sampler($\phi$:250mm, L:500mm) and hydraulic piston sampler($\phi$:76mm, L:850mm) in the marine clay of YONGYUDO and YEONGJONGDO in this research. Ratio of coefficient of consolidation was analyzed through comparison with C$\_$h/ by CPTu and C$\_$v/ and C$\_$h/ by existent consolidation test. According to analysis, coefficient of consolidation of block sample is fairly greater than coefficient of consolidation of piston sample. And the bigger diameter of undisturbed sample, sample disturbance could know decreasing. Coefficient of consolidation by Rowecell test measured more greatly than coefficient of consolidation by existent consolidation test. Rowecell test could know decreasing consolidation rate because of smear effect by Mandrel injection. Also, C$\_$h/ by CPTu shows deviation by each analysis method, selection of suitable analysis method judged by important leading in the coefficient of consolidation.

  • PDF

열전달계수에 대한 새로운 고찰 및 고-중압 터빈 케이싱 모형의 열응력 해석 (A new consideration for the heat transfer coefficient and an analysis of the thermal stress of the high-interim pressure turbine casing model)

  • 엄달선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.425-429
    • /
    • 2004
  • In real design of the high & interim pressure turbine casing, it is one of the important things to figure out its thermal strain exactly. In this paper, with the establishment of the new concept for the heat transfer coefficient of steam that is one of the factors in analysis of the thermal stress for turbine casing, an analysis was done for one of the high & interim pressure turbine casings in operating domestically. The sensitivity analysis of the heat transfer coefficient of steam to the thermal strain of the turbine casing was done with a 2-D simple model. The analysis was also done with switching of the material properties of the turbine casing and resulted in that the thermal strain of the turbine casing was not so sensitive to the heat transfer coefficient of steam. On the basis of this, 3-D analysis of the thermal strain for the high and interim pressure turbine casing was done.

  • PDF

BOX 형 지하구조물의 내진설계 기준 확립을 위한 해석기법개발 (Development of the Modified Seismic Coefficient Method to Establish Seismic Design Criteria of Buried Box Structures.)

  • 박성우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.194-201
    • /
    • 2000
  • In this study the modified seismic coefficient method for seismic analysis of buried box structures is developed for practical purpose. The loading coefficient in the modified seismic coefficient method is determined from the results of the response displacement analysis. In the developed method adequate velocity response spectrum in accordance with soil condition is also needed to seismic design of buried box structures, In order to investigate applicability of the modified seismic coefficient method various analyses are performed with different parameters such as depth of base rock height and width of box buried depth and value of standard penetration test. Results from the modified seismic coefficient method are compared with those of the response displacement method in terms of the maximum bending moment and the location of it. From the comparison it is shown that the feasibility of the modified seismic coefficient method for seismic analysis of buried box structures.

  • PDF

단순회귀분석에 의한 토층의 투수계수산정모델 제안 (Proposal for the Estimation Model of Coefficient of Permeability of Soil Layer using Linear Regression Analysis)

  • 이문세;류제천;임희대;박주환;김경수
    • 지질공학
    • /
    • 제18권1호
    • /
    • pp.27-36
    • /
    • 2008
  • 이 연구는 토질특성을 평가하는 주요 영향인자인 투수계수를 몇 가지 토질물성만으로 쉽게 산정할 수 있도록 단순회귀 분석을 이용하여 투수계수산정모델을 개발하였다. 이를 위한 연구지역은 강원도 평창군 진부면지역으로 총 45개 지점에서 토층시료를 채취하여 실내에서 여러 토질시험을 실시하였다. 상관분석을 통해 시험결과들 중 투수계수에 유효한 토질인자를 선별한 후 선별된 인자들과 직접투수시험에 의한 투수계수간의 관계를 단순회귀분석으로 공식화한 투수계수산정모델을 개발하였다. 또한, 개발된 투수계수산정모델과 직접투수시험 및 각 경험식들에 의한 투수계수를 비교 분석하여 모델의 적합성을 검증하였다. SPSS(statistical package for the social sciences)를 이용하여 여러 토질물성과 투수계수간의 상관관계를 분석한 결과 유효경, 간극비, 건조단위중량이 투수계수에 가장 크게 영향을 미치는 토질인자인 것으로 나타났다. 투수계수 산정모델에 의한 투수계수는 직접투수시험에 의한 투수계수와 거의 유사한 결과를 보였다. 따라서 개발된 투수계수산정모델은 연구지역과 같은 토질조건인 경우 토층의 투수계수 산정을 위한 모델로 이용이 가능할 것으로 사료된다.

지중 박스구조물의 지진시 거동 해석 (Numerical Analysis for Buried Box Structures during Earthquake)

  • 박성진
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.108-115
    • /
    • 2000
  • Numerical analysis of slop stability is presented using seismic displacement, response seismic coefficient, and earthquake response analysis methods. In seismic displacement and response seismic coefficient methods, horizontal static seismic force is considered as 0.2g while vertical static seismic force is not considered in analysis. For earthquake response analysis Hahinoha-wave is applied, It is found from result that analysis using response seismic coefficient method is much more conservative than that using seismic displacement method Also, analysis result using earthquake response analysis method is somewhat less conservative about 25% when compared with that using seismic displacement method.

  • PDF

Chatterjee의 ξ 계수에 대한 탐색적자료분석 (Exploratory data analysis for Chatterjee's ξ coefficient)

  • 장대흥
    • 응용통계연구
    • /
    • 제35권3호
    • /
    • pp.421-434
    • /
    • 2022
  • Chatterjee (2021)는 새로운 상관계수 ξ를 제안하였다. 두 가지 질문 (1. Anscombe's quartet 데이터셋에 대하여 ξ 계수는 구별이 가능한가?, 2. 다양한 종류의 산점도에서 데이터의 개수에 따라 ξ 계수 값의 변화는 어떠한가?)을 중심으로 ξ 계수에 대한 탐색적자료분석을 시도하였다. 세 가지 측도 (ξ 계수, 피어슨상관계수, 상호정보)를 서로 비교하였다.