• 제목/요약/키워드: Code formulas

검색결과 56건 처리시간 0.018초

Estimation of the Fundamental Period for Residential Buildings with Shear-Wall System

  • Chun, Young-Soo;Chang, Kug-Kwan;Lee, Li-Hyung
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.121-130
    • /
    • 2000
  • This study focused on evaluating the reliability of code formulas such as those of the current Korean Building Code(KBC 1988). UBC 1997, NBCC 1995. and BSLJ 1994 for estimating the fundamental period of RC apartment buildings with shear-wall dominant systems, representative of typical residential buildings in Korea. For this purpose, full-scale measurements were carried out on fifty RC apartment buildings, and these results were compared to those obtained by code formulas and also by dynamic analysis. Although these code formulas are based on the measured periods of buildings during various earthquakes and building period varies with the amplitude of structural deflection or strain level, ambient surveys should provide an effective tool for experimentally verifying the design period to the completed building. This comparison shows that comparatively large errors are likely to occure when the code formula of KBC 1988 is used, and all the other code formulas are not sufficient to estimate the fundamental period of apartment buildings with shear-wall dominant systems. An improved formula is proposed by regression analysis on the basis of the measured period data. The proposal is for the servicebility stress level, but it can also be applied for seismic code in the regions of low seismicity similar to Korea.

  • PDF

Exact Error and Outage Probability Formulas for Alamouti Space Time Code 2 $\times$ J

  • Kong, Hyung-Yun;Khuong, Ho-Van;Nam, Doo-Hee
    • Journal of Communications and Networks
    • /
    • 제9권2호
    • /
    • pp.177-184
    • /
    • 2007
  • Alamouti space-time code (STC) is a part of the UMTS-WCDMA standard. However, up to the best of our knowledge no exact closed-form outage and bit error probability (BEP) formulas for this famous code exists. Evaluating its performance through simulations is time-consuming and therefore, there should be analytical performance graphs to serve as a reference which are derived in this paper for coherently MPSK-modulated data. Additionally, analytical results take into account different channel fading levels from transmit antennas to receive ones.

Effective width of steel-concrete composite beams under negative moments in service stages

  • Zhu, Li;Ma, Qi;Yan, Wu-Tong;Han, Bing;Liu, Wei
    • Steel and Composite Structures
    • /
    • 제38권4호
    • /
    • pp.415-430
    • /
    • 2021
  • The effective flange width was usually introduced into elementary beam theory to consider the shear lag effect in steel-concrete composite beams. Previous studies have primarily focused on the effective width under positive moments and elastic loading, whereas it is still not clear for negative moment cases in the normal service stages. To account for this problem, this paper proposed simplified formulas for the effective flange width and reinforcement stress of composite beams under negative moments in service stages. First, a 10-degree-of-freedom (DOF) fiber beam element considering the shear lag effect and interfacial slip effect was proposed, and a computational procedure was developed in the OpenSees software. The accuracy and applicability of the proposed model were verified through comparisons with experimental results. Second, a method was proposed for determining the effective width of composite beams under negative moments based on reinforcement stress. Employing the proposed model, the simplified formulas were proposed via numerical fitting for cases under uniform loading and centralized loading at the mid-span. Finally, based on the proposed formulas, a simplified calculation method for the reinforcement stress in service stages was established. Comparisons were made between the proposed formulas and design code. The results showed that the design code method greatly underestimated the contribution of concrete under negative moments, leading to notable overestimations in the reinforcement stress and crack width.

원뿔 캐비테이터의 초공동 크기 추정 (An Estimation of the Size of Supercavities for Conical Cavitators)

  • 김형태;김병진;최정규;윤현걸
    • 대한조선학회논문집
    • /
    • 제53권2호
    • /
    • pp.92-100
    • /
    • 2016
  • A comparative method is applied to evaluate well-known formulas for estimating the size of supercavities of axisymmetric cavitators for the supercavitating underwater vehicle. Basic functional forms of these formulas are derived first for the cavity diameter from a momentum integral estimate and second for the cavity length from an asymptotic analysis of inviscid supercavity flows. The length and the diameter of axisymmetric supercavities estimated by each formula are compared, with available experimental data for a disk and a 45° conical cavitators, and also with computational results obtained by a CFD code, ‘fluent’, for conical cavitators of wide range of cone angles. Results for estimating the length and the diameter of the supercavities show in general a good agreement, which confirms the size of the supercavities for disk and conical cavitators can be estimated accurately by these simple formulas of an elementary function of cavitation number and drag coefficient of the cavitator. These formulas will be useful for from conceptual design of the cavitator to real-time control of the supercavitating underwater vehicle.

Fast analytical estimation of the influence zone depth, its numerical verification and FEM accuracy testing

  • Kuklik, Pavel;Broucek, Miroslav;Kopackova, Marie
    • Structural Engineering and Mechanics
    • /
    • 제33권5호
    • /
    • pp.635-647
    • /
    • 2009
  • For the calculation of foundation settlement it is recommended to take into account so called influence zone inside the subsoil bellow the foundation structure. Influence zone inside the subsoil is the region where the load has a substantial influence on the deformation of the soil skeleton. The soil skeleton is pre-consolidated or over consolidated due to the original geostatic stress state. An excavation changes the original geostatic stress state and it creates the space for the load transferred from upper structure. The theory of elastic layer in Westergard manner is selected for the vertical stress calculation. The depth of influence zone is calculated from the equality of the original geostatic stress and the new geostatic stress due to excavation combined with the vertical stress from the upper structure. Two close formulas are presented for the influence zone calculation. Using ADINA code we carried out several numerical examples to verify the proposed analytical formulas and to enhance their use in civil engineering practice. Otherwise, the FEM code accuracy can be control.

상부벽식-하부골조를 가진 복합구조물의고유주기 산정에 관한 연구 (A Study on the Natural Period Estimation for the Buildings of Upper Wall and Lower Frame Type)

  • 박기수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.170-177
    • /
    • 1999
  • The natural period calculation equations specified in the current building code are empirical formulas that depend on height and material type of the structure. Building with the upper wall and lower frame type is a unique structure which composed of two different structural system This type of structure needs either the deep transfer girder or the thick transfer plate that brings the sudden change of stiffness and mass. Therefore the natural period equations recommended by the current code can not be applied directly. In this study the natural period of building with typical plan obtained by dynamci analysis is compared with that of various codes. Ad approximate estimation equation for the natural period of building with the upper wall and lower frame type obtained by regression analysis is recommended. by the current code can not be applied directly. In this study the natural period of building with typical plan obtained by dynamic analysis is compared with that of various codes, And approximate estimation equation for the natural period of building with the upper wall and lower frame type obtained by regression analysis is recommended.

  • PDF

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

CRC 오류검출부호의 성능 분석 (Performance Analysis of CRC Error Detecting Codes)

  • 염흥렬;권주한;양승두;이만영
    • 한국통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.590-603
    • /
    • 1989
  • 본 논문에서는 단축 Hamming 부호의 일종이며 오류검출용 검사비트 수가 16인 CRC-CCITT 부호화 원시다항식 CRC 부호에 대한 성능 분석을 위하여 필수적으로 요구되는 중분포(weight distribution)를 구하는 기법과 오류검출 성능을 분석하는 기법을 제안하였고, 두 CRC(cyclic redundant code)부호를 CCITT에서 광대역 ISDN의 가입자망 인터페이스의 전송방식으로 권고된 ATM(asynchronous transfer mode)전송방식의 오류검출을 부호로 적용하여 현재 고려되고 있는 cell 크기에 대한 증분포 및 미검출오류확률(undetected error probability)을 구한 후, 두 오류검출부호의 성능을 비교/분석 하였다. 분석 결과, 현재 고려되는 셀 크기에 대해 CRC-CCITT 부호의 성능이 원시다항식 CRC 부호의 성능보다 더 우수함이 입증되었다 .이를 위한 모든 계산을 IBM PC/AT를 이용하여 수행하였다. 한편 본 논문에서 제안한 단축 Hamming 부호의 성능 분석 기법은 지금까지 디지틀 통신시스템에 적용되고 있는 또는 적용예정인 CRC 오류검출 부호의 성능 분석에 이용될 수 있다.

  • PDF

DS-CDMA 시스템을 위한 비동기식 동기 추적 회로의 성능 비교 분석 (Analysis and Comparison of Noncoherent Code Tracking Loops for DS-CDMA Systems)

  • 이경준;박형래;채수환
    • 한국항행학회논문지
    • /
    • 제1권1호
    • /
    • pp.70-80
    • /
    • 1997
  • 본 논문에서는 CDMA 이동전파 환경에서 두 가지 비동기식 동기 추적 회로 즉, TCTL과 MCTL의 성능을 비교, 분석한다. 먼저, 두 가지 방식에 대해 안정 상태에서의 지터 분산을 펄스 성형 필터, 타이밍 오프셋, 신호 대 잡음 비 및 루우프 대역폭의 함수로 이론적으로 유도한다. 또한, 루우프 필터의 설계 방법에 대해 2차 동기 추적회로를 중심으로 고찰한다. 끝으로, 동기 추적 오차에 의한 BER 성능 저하를 ETRI 에 의해 IMT-2000용으로 설계된 CDMA 시스템의 역방향 링크에 대해 분석한다.

  • PDF

Modified models predicting punching capacity of edge column-slab joints considering different codes

  • Hamdy A. Elgohary;Mohamed A. El Zareef
    • Structural Engineering and Mechanics
    • /
    • 제89권4호
    • /
    • pp.363-374
    • /
    • 2024
  • Significant changes have been made to estimate the punching shear capacity for edge column-slab joints in the latest editions of most current codes. The revised equations account for axial forces as well as moments conveyed to columns from slabs, which have a substantial impact on the punching resistance of such joints. Many key design parameters, such as reinforcement-ratio, concrete strength, size-effect, and critical-section perimeter, were treated differently or even ignored in various code provisions. Consequently, wide ranges of predicted punching shear strength were detected by applying different code formulas. Therefore, it is essential to assess the various current Codes' design-equations. Because of the similarity in estimated outcomes, only the ACI, EC, and SNiP are used in this study to cover a wide range of estimation ranges from highly conservative to unconservative. This paper is devoted to analyzing the techniques in these code provisions, comparing the estimated punching resistance with available experimental data, and finally developing efficient models predicting the punching capacity of edge column-slab connections. 63 samples from past investigations were chosen for validation. To appropriately predict the punching shear, newly updated equations for ACI and SNiP are provided based on nonlinear regression analysis. The proposed equations'results match the experimental data quite well.