• Title/Summary/Keyword: Cobalt ions

Search Result 146, Processing Time 0.023 seconds

The Properties of Mn, Ni, and Al Doped Cobalt Ferrites Grown by Sol-Gel Method

  • Choi, Seung Han
    • Korean Journal of Materials Research
    • /
    • v.28 no.7
    • /
    • pp.371-375
    • /
    • 2018
  • The manganese-, nickel-, and aluminum-doped cobalt ferrite powders, $Mn_{0.2}Co_{0.8}Fe_2O_4$, $Ni_{0.2}Co_{0.8}Fe_2O_4$, and $Al_{0.2}CoFe_{1.8}O_4$, are fabricated by the sol-gel method, and the crystallographic and magnetic properties of the powders are studied in comparison with those of $CoFe_2O_4$. All the ferrite powders are nano-sized and have a single spinel structure with the lattice constant increasing in $Mn_{0.2}Co_{0.8}Fe_2O_4$ but decreasing in $Ni_{0.2}Co_{0.8}Fe_2O_4$ and $Al_{0.2}CoFe_{1.8}O_4$. All the $M{\ddot{o}}ssbauer$ spectra are fitted as a superposition of two Zeeman sextets due to the tetrahedral and octahedral sites of the $Fe^{3+}$ ions. The values of the magnetic hyperfine fields of $Ni_{0.2}Co_{0.8}Fe_2O_4$ are somewhat increased in the A and B sites, while those of $Mn_{0.2}Co_{0.8}Fe_2O_4$ and $Al_{0.2}CoFe_{1.8}O_4$ are decreased. The variation of $M{\ddot{o}}ssbauer$ parameters is explained using the cation distribution equation, superexchange interaction and particle size. The hysteresis curves of the ferrite powders reveal a typical soft ferrite pattern. The variation in the values of saturation magnetization and coercivity are explained in terms of the site distributions, particle sizes and the spin magnetic moments of the doped ions.

Separation of Co(II), Ni(II), and Cu(II) from Sulfuric Acid Solution by Solvent Extraction (황산용액에서 용매추출에 의한 코발트(II), 니켈(II) 및 구리(II) 분리)

  • Moon, Hyun Seung;Song, Si Jeong;Tran, Thanh Tuan;Lee, Man Seung
    • Resources Recycling
    • /
    • v.31 no.1
    • /
    • pp.21-28
    • /
    • 2022
  • The smelting reduction of spent lithium-ion batteries results in metallic alloys of cobalt, nickel, and copper. To develop a process to separate the metallic alloys, leaching of the metallic mixtures of these three metals with H2SO4 solution containing 3% H2O2 dissolved all the cobalt and nickel, together with 9.6% of the copper. Cyanex 301 selectively extracted Cu(II) from the leaching solution, and copper ions were completely stripped with 30% aqua regia. Selective extraction of Co(II) from a Cu(II)-free raffinate was possible using the ionic liquid ALi-SCN. Three-stage cross-current stripping of the loaded ALi-SCN by a 15% NH3 solution resulted in the complete stripping of Co(II). A process was proposed to separate the three metal ions from the sulfuric acid leaching solutions of metallic mixtures by employing solvent extraction.

Adsorption and Separation of U (VI), Co (II), and Dy (III) Metal Ions on Crown Synthetic Resin

  • Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.10 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • Synthetic resins were combined 1-aza-12-crown-4 macrocyclic ligand with styrene divinylbenzene copolymer having 1%, 2%, 8%, and 16% crosslink by a substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, SEM, surface area, and IR-spectrum. As the results of the effects of pH, crosslink of synthetic resin, and dielectric constant of a solvent on metal ion adsorption for resin adsorbent, the metal ions showed high adsorption at pH 3 or over. Adsorption selectivity for the resin in ethanol solvent was the order of uranium ($UO_2{^{2+}}$) > cobalt ($Co^{2+}$) > dysprosium ($Dy^{3+}$) ion, adsorbability of the metal ion was the crosslink in order of 1%, 2%, 8%, and 16% and it was increased with the lower dielectric constant. In addition, theses metal ions could be separated in the column with 1% crosslink resin by using nitric acid (pH 2.0) as an eluent.

Complexes of Polyvalent Metal Ions (Ⅶ). Complexes of Cadmium, Cobalt and Nickel with Hydroxycarboxylic Acids in Aqueous, Ethanol-Water and Acetone-Water Solutions$^*$

  • Park, Joon-W.;Mukherjee, C.
    • Bulletin of the Korean Chemical Society
    • /
    • v.1 no.3
    • /
    • pp.105-109
    • /
    • 1980
  • A general spectroscopic method is described for studies on the complex formation between metal ions and ligands, and is applied to $Cu^{2+}$ and $Ca^{2+}$binding to glycosaminoglycans. The order of binding constants for both ions is heparin >dermatan sulfate >chondroitin sulfate. The electrostatic forces are shown to be the predominant factor in the interaction. The 2- to 3-fold higher affinity for $Cu^{2+}$ than for $Ca^{2+}$ is obtained for heparin and dermatan sulfate, but little difference for chondroitin sulfate. These results are explained as chelation of both carboxyl and sulfate groups to $Cu^{2+}$ in former cases. The difference of binding constants among glycosaminoglycans is related to proposed various biological functions of the biopolymers.

5-Bromo-Ph4-BTPhen Ligand for Selective Removal of Strontium and Cobalt From Water

  • Jang, Jiseon;Harwood, Laurence M.;Cowell, Joe;Afsar, Ashfaq;Lee, Dae Sung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.05a
    • /
    • pp.183-183
    • /
    • 2018
  • In this study, 5-bromo-2,9-bis(5,6-diphenyl-1,2,4-triazin-3-yl)-1,10-phenanthroline (5-bromo-Ph4-BTPhen) was synthesized and evaluated for its ability to remove major radionuclides ($Cs^+$, $Sr^{2+}$, and $Co^{2+}$). The synthesized ligand removed both $Sr^{2+}$ and $Co^{2+}$ from $1mg\;L^{-1}$ aqueous solutions with extraction efficiencies of up to 99% at neutral and alkaline pH. The $Sr^{2+}$ and $Co^{2+}$ removal efficiencies decreased as a consequence of the higher bonding strengths of competing metal ions to the N-donor atoms in the cavity of the ligand; competing divalent ions affected the $Sr^{2+}$ and $Co^{2+}$ removal efficiencies more than monovalent ions.

  • PDF

Electrosorption and Separation of $Co^{2+}$ and $Sr^{2+}$ Ions from Decontaminated Liquid Wastes

  • Kim, Jun-Soo;Jung, Chong-Hun;Oh, Won-Zin;Ryu, Seung-Kon
    • Carbon letters
    • /
    • v.3 no.1
    • /
    • pp.6-12
    • /
    • 2002
  • A study on the electrosorption of $Co^{2+}$ and $Sr^{2+}$ ions onto a porous activated carbon fiber (ACF) was performed to treat radioactive liquid wastes resulting from chemical or electrochemical decontamination and to regenerate the spent carbon electrode. The result of batch electrosorption experiments showed that applied negative potential increased adsorption kinetics and capacity in comparison with open-circuit potential (OCP) adsorption for $Co^{2+}$ and $Sr^{2+}$ ions. The adsorbed $Co^{2+}$ and $Sr^{2+}$ ions are released from the carbon fiber by applying a positive potential on the electrode, showing the reversibility of the sorption process. The possibility of application of the electrosorption technique to the separation of radionuclides was examined. The result of a selective removal experiments of a single component from a mixed solution showed that perfect separation of $Co^{2+}$ and $Sr^{2+}$ ions was possible by the electrosorption process.

  • PDF

Metal Ion Released from Old Prostheses May Affect Oral Lesions: A Pilot Study

  • Ju, Hye-Min;Kim, Ji-Su;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.4
    • /
    • pp.131-135
    • /
    • 2018
  • Purpose: To investigate the correlation between the amount of salivary metal ions released from fixed prostheses and the period of restoration insertion, and to evaluate the correlation between the type and amount of metal ions in saliva and oral lesions (OL). Methods: Based on the oldest prosthesis, we divided patients into two groups: more than 5 years (n=19) and less than 5 years (n=10). Patients were also divided into two groups by another criteria: the one with the presence (n=15), and the one with absence (n=14) of OL, and the amounts of metal ions were examined. Metal ions-gold (Au), copper, cobalt (Co), chromium (Cr), nickel, zinc, aluminum, palladium (Pd), tin, and platinum (Pt)-were measured using laser ablation microprobe inductively coupled plasma mass spectrometry. Results: Significantly higher quantities of Co, Pt, and Pd ions were released in patients with fixed prosthesis of more than 5 years (p<0.05). Measurement of the average amount of salivary metal ions was performed on patients with and without OL - Significantly higher amounts of Cr, Pd and Au ions were released in patients with OL (p<0.05). Conclusions: Old prostheses (${\geq}5years$) released metal ions, and among them were Co, Pt and Pd ions more than others. Patients with OL showed significantly higher levels of ion release, especially Cr, Pd and Au. There was a positive correlation between the amount of a certain kind of released metal ions, especially Pd, and the development of OL. Salivary Pd ion released from old prostheses could affect the pathogenesis of OL; therefore, long-term follow-up is important.

Direct and Derivative Spectrophotometric Determination of Cobalt (II) in Microgram Quantities with 2-Hydroxy-3-methoxy Benzaldehyde Thiosemicarbazone (2-Hydroxy-3-methoxy Benzaldehyde Thiosemicarbazone를 사용하여 마이크로 그램 코발트(II)의 직접 및 유도 분광광도법에 의한 정량)

  • Kumar, A.Praveen;Reddy, P.Raveendra;Reddy, V.Krishna
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.331-338
    • /
    • 2007
  • A rapid, simple and sensitive spectrophotometric method was developed for the determination of cobalt(II) using 2-hydroxy-3-methoxy benzaldehyde thiosemicarbazone (HMBATSC) as a analytical reagent. The metal ion in aqueous medium forms a brown coloured complex with HMBATSC at pH 6.0. The complex has two absorption maxima at 375 nm and 390 nm. At 375 nm, the reagent shows considerable absorbance, while at 390 nm the reagent does not shows appreciable absorbance. Hence, analytical studies were carried out at 390 nm. Beer's law is obeyed in the range of 0.059-2.357 μg ml-1 of Co(II). The molar absorptivity and Sandall's sensitivity of the method are 2.74×104 l mol-1 cm-1 and 0.0024 μg cm-2 respectively. The interference of various diverse ions has been studied. The complex has 1:2 [Co(II)- HMBATSC] stoichiometry. A method for the determination of cobalt(II) by second order derivative spectrophotometry has also been proposed. The proposed methods were applied for the determination of cobalt(II) in alloy steels, vitamin B12 and in some biological samples.

Prediction of the Dynamic Adsorption Behaviors of the Uranium and Cobalt Ions in a Fixed Bed by Surface Modified Activated Carbon (표면개질 활성탄을 이용한 고정층에서 우라늄 및 코발트 이온의 동적 흡착거동 모사)

  • Geun-IL Park;Jung-Won Lee;Kee-Chan Song;In-Tae Kim;Kwang-Wook Kim;Myung-Seung Yang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.81-92
    • /
    • 2003
  • In order to predict the dynamic behaviors of uranium and cobalt in a fixed bed at various influent pH values of liquid waste, the adsorption system is regarded as a multi-component adsorption between each ionic species in the solution. Langmuir isotherm parameters of each species were extracted by incorporating equilibrium data with the solution chemistry of the uranium and cobalt using IAST. Prediction results were in good agreement with the experimental data, except for a high concentration and pH. Although there was some limitations in predicting the cobalt adsorption, this method may be useful in analyzing a complex adsorption system where various kinds of ionic species exist in a solution.

  • PDF

Flow Injection Spectrophotometric Determination of Cobalt with 2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)aniline (2-(5-브로모-2-피리딜아조)-5-(N-프로필-N-슬포프로필아미노)아닐린을 사용하여 흐름주입법에 의한 코발트의 분광광도법적 정량)

  • Kang, Sam Woo;Kim, In Yong;Han, Hong Seok;Lee, Seung Seok
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.57-63
    • /
    • 1993
  • Spectrophotometric determination of cobalt by flow injection method is described. 2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino) aniline rapidly forms a water-soluble complex with cobalt in $NH_3-NH_4Cl$ buffer solution at pH 10.5. The absorption maxima of this complex is at 545 nm with molar absorptivity of $58000L\;mol^{-1}\;cm^{-1}$. The calibration curve of cobalt is linear over the range of 0.1 to 0.6ppm and the detection limit is 25ppb. The relative standard deviation is ${\pm}0.72%$ for 0.5ppm and the sampling rate is $60samples\;hr^{-1}$. The interfering effect of some cations and anions was investigated. Ni(II), Cu(II), Fe(III) and $CN^-$ interfered severely. The interfering effect of these matallic ions could be decreased by adding $1.0{\times}10^{-3}M$ EDTA solution to the carrier stream.

  • PDF