• 제목/요약/키워드: Co-Generator

검색결과 547건 처리시간 0.033초

On-line 발전기 주파수응답시험 개발 및 적용에 관한 연구 (Study on Development & Implementation of Online Generator Frequency Response Test)

  • 오창수;곽월환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.48-49
    • /
    • 2006
  • Recently, Importance of Generator's Active/Reactive Power Control Capability is highly emphasized for prevention of Large Blackout. Especially, Generator's frequency Response Capability is important to the Power System Frequency Stability. This paper deals with the Development & Implementation of Each Generator Frequency Response Capability Test via the Injection of Artificial Frequency to the Online Generator. Actual On-line Generator's frequency Response Test was successfully implemented to 13 Generator having various fuel source.

  • PDF

소형열병합 발전설비 계통연계 상용운전에 관한 연구 (A Study for Small Cogeneration System Intertie)

  • 박경원;김왕태;윤갑구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.166-168
    • /
    • 2001
  • Generation by the privately owned generators, which are normally operated has occupied about 10% of total generation. Recently the small co-generation employed gas engine has been introduced and attracted public interest. For privately owned generator to be paralleled Utilities, a customer complies with Generator Parallel Operation Guideline set by Utilities and installs related protective relays. But the guideline is not specified to small co-generation, only provides parallel operation of privately owned generator. So applying this guideline, initial investment can be too high comparing to total co-generation cost. Besides there is no specified guide about ALTS, which arises asynchronous problem. In this paper we analyzed guideline and technical problem when small co-generation is paralleled. And additionally needed researching area to improve distribution of small co-generation is discussed.

  • PDF

CO2배출 최소화를 고려한 발전기보수유지계획의 수립 (Establishment of Generator Maintenance Scheduling Considering Minimization of CO2 Emissions)

  • 오태곤;백웅기;최재석
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.705-710
    • /
    • 2011
  • This paper proposes establishment of generator maintenance scheduling(GMS) considering minimization of $CO_2$ emissions. The objective function model to minimize $CO_2$ emissions is used in this paper. In this paper, and also, GMS is established due to freedom of GMS of generators owned by a designated generation company. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model in Korea in 2010.

현장 계측을 통한 산업용 열병합 발전설비 모델 파라미터 결정 (Model Parameter Determination of Industrial Co-generator Model Parameters through Filed Measurement)

  • 김학만
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.159-165
    • /
    • 2007
  • 본 논문에서는 열병합 발전시스템의 특성 실험으로 구한 실측데이터를 이용하여 발전시스템의 모델 파라미터를 결정하는 기법을 제안하였고 이에 대한 타당성을 입증하져다. 제안한 모델은 발전기, 여자시스템, 터빈/조속기를 주로 다루었다. 도출된 파라미터의 타당성을 검토하기 위해서 실측값과 시뮬레이션 결과를 비교하였다. 시뮬레이션 결과를 실측결과와 일치함을 확인하였습니다.

대형 터빈 발전기용 고정자 권선의 1000 thermal cycle 후 전기적 특성 변화 (Electrical Degradation of Stator Bars for Large Turbine Generator after 1000 Thermal Cycles)

  • 강명국;김태희;이재권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.975-976
    • /
    • 2007
  • Thermal and mechanical stresses, caused by repetitive start and stop and load fluctuation during long time operation, on winding stator bars are one of the main causes for electrical degradation of insulating materials. To understand the degradation process, we manufactured bar specimens with the same processes that make generator winding stator bars and the specimens were subjected to various degrees of thermal cycling. Measurements of the insulation properties, such as dissipation factor, tip-up and partial discharge, for un-aged specimens and for specimens aged by thermal cycling at 50, 100, 250, 500 and 1000 thermal cycles were performed. Finally all specimens were tested to obtain electrical breakdown voltages. In this paper we present the data and electrical degradation analysis results obtained during this program.

  • PDF

System Generator를 이용한 카오스 신호 발생기의 FPGA 구현 (FPGA Implementation of Chaotic Signal Generator Using System generator)

  • 허용원;하정우;장은영;변건식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.336-339
    • /
    • 2007
  • 카오스 신호는 공학, 의학 그리고 생물학과 같은 모든 분야에서 많이 이용되고 있으며 최근 카오스 신호를 이용한 디지털 통신시스템에 대한 연구도 활발히 이루어지고 있다. 본 논문은 카오스 신호를 디지털 통신시스템에 적용할 목적으로 System Generator를 이용하여 비선형 방정식으로 구성된 6개의 카오스 신호 발생기를 설계하고 FPGA로 하드웨어를 구현하였다. 이 결과로부터 Hardware co-simulation으로 본 설계를 검증하기 위해 비트 스트림을 FPGA 보드로 로드하였다. 또한 6개의 카오스 발생기의 성능을 평가하기 위해 타이밍 해석을 통한 최대 동작 주파수와 사용한 로직의 resource량을 조사하여 비교하였다.

  • PDF

연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구 (A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors)

  • 손근식;소수현
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.236-244
    • /
    • 2021
  • 연구목적: 연기/CO/열 복합형 화재감지기와 무선 IoT통신을 결합한 IoT 멀티화재감지기를 개발하고 화재감지 실험을 통하여 연기/CO/열 복합형 IoT 멀티화재감지기의 화재감지성능을 확인하는 것을 목적으로 한다. 연구방법: 연기/CO 복합형 과 연기/열 복합형의 IoT 멀티화재감지기를 연기발생기와 면 심지 연소를 통하여 화재감지성능을 실험하였으며, 화제 신호를 발하는 기준을 확인하였다. 연구결과: 연기/CO 복합형 IoT 멀티 화재감지기는 면심지 연소 실험에서 화재를 감지하였으나 연기발생기 실험에서는 화재를 감지하지 않았다. 반면 연기/열 복합형 IoT 멀티 화재감지기는 두 실험 모두 화재를 감지하지 않았다. 결론: 연기/CO 복합형 IoT 멀티화재감지기는 CO가 포함된 연기만을 감지하였으며, 연기/열 복합형 IoT 멀티 화재감지기는 열의 부족에 의해 화재를 잠지하지 않았다. 이와 같은 결과로 개발된 IoT 멀티 화재감지기는 면심지 연소 실험과 연기발생기 실험을 통해 2가지 센서의 기준값 이상 신호를 검출하여야 화재 신호를 발한다는 것을 확인하였다.

PSO 기반 동기발전기 시스템 모델정수 추정에 관한 연구 (A Study on Parameter Estimation of the Synchronous Generator System based on the Modified PSO)

  • 최형주;김인수;이흥호
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.8-15
    • /
    • 2015
  • This paper includes a method for estimating the parameter of a synchronous generator and exciter using the modified particle swarm optimization. A solid round rotor synchronous generator and exciter have been modeled with the saturation function. They are regarded as state of being cooperative to a infinite bus. The behavior characteristic of all particles assigned to a parameter needs to be reflected in the PSO algorithm to fine out more close result to the optimal solution. The results of the simulation to estimate the parameters of the synchronous generator and exciter in the modified PSO algorithm are described.

CORDIC을 이용한 OFDM 시스템의 주파수 옵셋 제거 회로의 FPGA구현 (FPGA Implementation of Frequency Offset Compensation using CORDIC Algorithm in OFDM)

  • 이미진;윤미경;채우청;변건식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.363-366
    • /
    • 2007
  • 본 논문은 OFDM 시스템에서 주파수 옵셋을 제거하기 위한 회로를 Simulink로 설계하여 성능을 평가하고, FPGA 구현을 위해 System Generator로 설꼐하였다. System generator 모델을 바탕으로 HDL 코드를 생성하고, RTL schematic도 생성하였다. 그리고 Hardware Co-simulation 과정을 통해 Target Device에 로딩하여 성능 검증을 하였으며, 타이밍 해석과 resource량도 확인하였다.

  • PDF