• Title/Summary/Keyword: Closing Department

Search Result 453, Processing Time 0.023 seconds

Changes in Macrobenthic Community Structure on Gunsan Tidal Flat after the Closing of the Saemangeum 4th Dyke (새만금 4호 방조제 연결 후 군산갯벌 대형저서동물군집 변화)

  • Koo, Bon-Joo;Shin, Sang-Ho;Woo, Han-Jun;Kim, Eun-Soo;Je, Jong-Geel
    • Ocean and Polar Research
    • /
    • v.30 no.4
    • /
    • pp.497-507
    • /
    • 2008
  • With the reduction of tidal currents by the closing of the Saemangeun 4th dyke, sedimentary environments on the Gunsan tidal flat, the nearest inner flat from the 4th dyke, has been severely changed, which might affect macrobenthic assemblages on the habitats. In order to investigate changes in macrobenthic community structure on Gunsan tidal flat, field surveys were seasonally conducted at seven stations from April 2002 to November, 2005. Sedimentary facies on the study area were shifted into muddominant facies. The fine sediment has been greatly deposited on the tidal flat with accumulation of organic materials after closing the water passage of 4th dyke section. These drastic variations in environments gave rise to change in macrobenthic community structure. Since the closure of the 4th dyke, the number of species of macrobenthos has gradually decreased. And the filter feeders and sand-favored species such as Urothoe convexa, Macrophthalmus dilatatus, Umbonium thomasi, and Mactra veneriformis have been replaced by the deposit feeders such as Macrophthalmus japonicus and Ilyoplax pingi. MDS ordination based on Bray-Curtis similarity from forth-root transformed species abundance data showed that the macrobenthic communities have passed through three succession stages from 2002 to 2005. During the third stage of 2005 opportunistic species such as Prionospio japonica, Heteromastus filiformis and Sinocorophium sinensis increased in population on the tidal flat.

A STUDY ON THE DETERMINATION OF THE NEUTRAL ZONE AT THE HABITUAL OPENING AND CLOSING MANDIBULAR MOVEMENTS (하악의 습관적 개폐구 운동시 중립대 결정에 관한 연구)

  • Lee, Don-Oh;Kay, Kee-Sung;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.123-135
    • /
    • 1990
  • It would be of importance to determine the neutral Tone by a resultant axis of relation on relation to the mandible in understanding the biomechanics of the mandibular movement. In this study, the neutral zone at the habitual opening and closing mandibular movements is the shape of the paths described by a minimum moving point occured as an average center of the determined instantaneous centers of rotation. Twenty, aged $23{\sim}25$, male dental students without Temporomandibular disorders and with normal occlusion clinically were selected for the study. The habitual opening and closing mandibular movements were recorded by the Gnathorecouder and analyzed by the computer program of a planer rigid body model and the determined method of a minimum moving point. The results obtained from this study were as follows. 1. The minimum moving points were placed in the body of the mandible except two subjects. 2. The mean of maximum displacements of a minimum moving point was $0.62{\pm}0.08cm$ on X-axis and $0.73{\pm}0.16cm$ on y-axis. 3. The mean of maximum displacements of a minimum moving point was $3.39{\pm}0.62cm$ 4. The position and shape of the neutral zone were determined by the position, displacements, and moving distances of a minimum moving point.

  • PDF

SURFACE CHANGE AND FIT OF TIN-COATED ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING (TiN 코팅된 지대주 나사의 반복 착탈 후 표면 변화와 적합도에 관한 연구)

  • Kim, Jong-Nam;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.119-130
    • /
    • 2007
  • Statement of problem: A few dry lubricants were applied to abutment screws for the improvement of joint stability. Purpose: The purpose of this study was to evaluate the surface change and fit of TiN-Coated abutment screw through the examination of tested screws in the field emission scanning electron microscope(FE-SEM;Netherland, Phillips co., model:XL 30 SFEG) after repeated closing and opening. Materials and method: Titanium(3i/implant Innovations Inc, USA) and Gold-Tite abutment screws(3i/implant Innovations Inc, USA) were selected for Group A and C respectively. TiN coated titanium abutment screws were also divided into two groups, Group B and D. Abutment screws of each group and the fit of abutment screw/implant fixture/abutment were observed on FE-SEM after repeated closing and opening test respectively. Results: 1. The abutment screws of TiN coated groups(Group B and D) showed more remarkable wear resistance in the threads of the screw than those of the other group(Group A and C). 2. There were more severe wear and defect of TiN coating in Group D tightened to 32 Ncm than Group B to 20 Ncm. 3. There was no difference in the fit of abutment screw/fixture/abutment among four groups, Group A, Group B, Group C and Group D. Conclusion: Under the conditions of this study, it is suggested that TiN coating of abutment screw be clinically acceptable and be expected to reduce the risk of abutment screw loosening. TiN coating of abutment screw showed good resistance against wear and the adequate fit of abutment screw/implant fixture/abutment.

Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography (문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구)

  • Yoon, Hong-Joo;Lee, Yong-Ki;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.

DETORQUE FORCE OF TiN-COATED ABUTMENT SCREW WITH VARIOUS COATING THICKNESS AFTER REPEATED CLOSING AND OPENING

  • Kim, Han-Su;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.769-779
    • /
    • 2007
  • Statement of problem. When TiN coating is applied to the abutment screw, occurrence of greater preload and prevention of the screw loosening could be expected due to decrease of frictional resistance. However, the proper thickness of TiN coating on abutment screw has not been yet reported. Purpose. The purpose of this study is to find out the appropriate TiN coating thickness by evaluating the detorque force and the surface change of titanium abutment screw with various TiN coating thickness. Material and methods. 1. Material Thirty five non-coated abutment screws were prepared for TiN coating. TiN coatings were prepared by Arc ion plating method. Depending on the coating deposition time(CDT), experimental groups were divided into 6 groups(CDT 30min, 60min, 90min, 120min, 150min, 180min) and those of 1 group was not coated as a control group. Each group was made up of 5 abutment screws. 2. Methods FE-SEM(Field Emission Scanning Electron Microscoper) and EDX(Energy Dispersive X-ray Spectroscopy) were used to observe the surface of the abutment screw. Electric scales was used to measure the weight of the abutment screw after the repeated closing and opening of 10 trials. Detorque force was measured with digital torque gauge, at each trial. Results. 1. As the coating deposition time increased, the surface became more consistent and smooth. 2. As for the abutment screws that were TiN coated for more than 60 minutes, no surface change was found after the repeated closing and opening. 3. The TiN coated abutment screws showed less weight change than the non-coated abutment screws. 4. The TiN coated abutment screws showed higher mean detorque force than the noncoated abutment screws. 5. The abutment screw coated for 60 minutes showed the highest mean detorque force. Conclusion. The coating layer of proper thickness is demanded to obtain consistent and smooth coating surface, resistance to wear, and increased detorque force of the abutment screw. In conclusion, the coating deposition time of 60 minutes indicated improved mechanical property, when TiN coating was conducted on titanium abutment screw.

Effects of Proprioceptive Neuromuscular Facilitation Program Combined with Dynamic Neuromuscular Stabilization Approach on Balance in Patient with Cerebellum Atrophy -Case Report- (동적 신경근 안정화 접근법과 결합한 PNF 중재 프로그램이 소뇌 위축 환자의 균형에 미치는 영향 -사례보고-)

  • Na, Eun-Jin;Moon, Sang-Hyun;Kim, Eun-Kyung;Park, Du-Jin
    • PNF and Movement
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • Purpose: This case report examines the influence of proprioceptive neuromuscular facilitation (PNF) combined with a dynamic neuromuscular stabilization approach on balance in patients with cerebellar atrophy. Methods: The target subject of this case report was a 34-year-old woman who was informed of the purpose of this research and voluntarily agreed to participate in it. The case report conformed to research ethics based on the Helsinki Declaration. The target subject was confirmed to have cerebellar atrophy from an unknown cause in 2009 and was diagnosed with slight ataxia. At that time, she could carry out daily activities without physical therapy. On May 19, 2015, she suffered both a subdural hemorrhage (SDH) and subarachnoid hemorrhage (SAH) in a traffic accident. She was urgently moved to the emergency room and managed by nonsurgical treatment, and then, the cerebellar atrophy and ataxia gradually deteriorated. To evaluate the patient's balance capacity before and after intervention, the trunk impairment scale (TIS), trunk impairment scale (OLST) during eye-closing/opening, timed up and go test (TUG), and visual analogue scale (VAS) were conducted. The PNF intervention program was executed for 30 min, four times a week, for three weeks. Results: The TIS and OLST during eye-closing/opening were improved by as much as a point, by 8.15 s and 6.21 s, respectively, after applying the PNF program. TUG and VAS decreased by 1.33 s and 3 points, respectively, after intervention. According to the result, the OLST during eye-closing/opening and VAS improved remarkably in comparison with those before intervention. Conclusion: As the final result of the case report, PNF intervention combined with DNSA more effectively improved the static balance capacity, such as the OLST during eye-closing/opening and VAS, compared to the dynamic balance capacity. In addition, the intervention duration and period of the exercise program are recommended to be more than 1 h a day for four weeks considering the learning ability of a patient with cerebellar atrophy.

A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels (수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chuung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.63-70
    • /
    • 2015
  • Crevices between window and window frame cause not only heat losses but also serve path to sound transmission and infiltration of fine dusts that are harmful to humans. There were many efforts in the past to eliminate these crevices but because of the windows' indispensable function of opening and closing, it was an unsolvable problem. In this study, a new type sliding window is developed by applying horizontally rolling wheels to implement a surface sealing which is excellent for enhancing air tightness. To evaluate the feasibility of the newly developed window, forces for opening and closing, durability and air tightness were testet according to Korean Testing Standards. Force for opening a 2000 N window is 30 N. It endured 100,000 cycles of opening and closing. Infiltration was $0.00m^3/(m^2h)$ for a pressure difference of 10 Pa. Since this window has few moving parts, it has favorable features of low cost and few breakdown.

Mandibular Movement Pattern During Mastication (저작시(咀嚼時) 하악운동(下顎運動)의 양상(樣相))

  • Bae, Young-Soo;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.117-124
    • /
    • 1986
  • Numerous studies have been reported on the movement of the jaw during chewing. However, there is still much controversy. The purposes of this study were to observe the jaw movement during mastication and to provide the information in prosthodontic treatment and diagnosis of temporomandibular disorder. The author analyzed the time and characteristics of the masticatory movement during chewing using mandibular kinesiograph in 24 subjects, 17 males 7 females, age of 22-27 without orofacial problems. The obtained results were as follows: The duration of single chewing cycle was $515{\pm}87msec.$. Comparing the three phases of the chewing cycle (opening, closing, centric pause), the closing phase had the longest duration, and the centric pause had the shortest duration. The maximal laterotrusive movement of the mandible druing chewing was $3.5{\pm}1mm$. The maximal mediotrusive movement of the mandible during chewing was $1.0{\pm}0.7mm$. The maximal vertical velocity of the mandible during chewing was $120{\pm}28mm/sec.$ in opening phase, and $109{\pm}21mm/sec.$ in closing phase.

  • PDF

The Impact of Climate Changes on Ski Industry in Central Region of Korea: The Case of Yongpyong.Yangji.Jisan Ski Resort (기후변화가 우리나라 중부지방의 스키산업에 미치는 영향 -용평.양지.지산 스키리조트를 사례로-)

  • Heo, In-Hye;Lee, Seung-Ho
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.4
    • /
    • pp.444-460
    • /
    • 2010
  • This study analyzed the changes in climate elements that affects the opening and closing dates of the ski resorts, and the snowmaking. Climatology data from the weather stations adjacent to the ski resorts in the central region of Korea were analysed to understand the snowmakig status. The fan type snowmaker has been used in the capital region (over 94% of the whole snowmaking), while the gun type snowmaker has been used in Yongpyong. There has been obviously an increased trend of the daily minimum temperature in November in Daegwallyeong and a little decreased trend in Icheon after 1980s. That caused the effect on the opening dates of the ski resort in the capital region of Korea during 2000s. Closing dates of ski resorts were earlier in the capital region (with $2{\sim}4^{\circ}C$ of daily maximum temperature in mid-February) than in Yongpyong. The obviously increasing rate of the snowmelting day in Icheon also hardened the management and maintenance of the ski resorts in the capital region of Korea.

THE EFFECT OF THE AMOUNT OF INTERDENTAL SPACING ON THE STRESS DISTRIBUTION IN MAXILLARY CENTRAL INCISORS RESTORED WITH PORCELAIN LAMINATE VENEER AND COMPOSITE RESIN: A 3D-FINITE ELEMENT ANALYSIS (도재 라미네이트와 복합레진 수복 시 치간이개 양에 따른 접착계면의 응력분포에 관한 3차원 유한요소법적 연구)

  • Hong, Jun-Bae;Tak, Seung-Min;Baek, Seung-Ho;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.30-39
    • /
    • 2010
  • This study evaluated the influence of the type of restoration and the amount of interdental spacing on the stress distribution in maxillary central incisors restored by means of porcelain laminate veneers and direct composite resin restorations. Three-dimensional finite element models were fabricated to represent different types of restorations. Four clinical situations were considered. Type I, closing diastema using composite resin. Labial border of composite resin was extended just enough to cover the interdental space; Type II, closing diastema using composite resin without reduction of labial surface. Labial border of composite resin was extended distally to cover the half of the total labial surface; Type III, closing diastema using composite resin with reduction of labial surface. Labial border of the preparation and restored composite resin was extended distally two-thirds of the total labial surface; Type IV, closing diastema using porcelain laminate veneer with a feathered-edge preparation technique. Four different interdental spaces (1.0, 2.0. 3.0, 4.0 mm) were applied for each type of restorations. For all types of restoration, adding the width of free extension of the porcelain laminate veneer and composite resin increased the stress occurred at the bonding layer. The maximum stress values observed at the bonding layer of Type IV were higher than that of Type I, II and III. However, the increasing rate of maximum stress value of Type IV was lower than that of Type I, II and III.