• Title/Summary/Keyword: Close Contact

Search Result 417, Processing Time 0.029 seconds

Development of a Finite Element Model for Studying the Occupant Behavior of a Mid-Size Truck with a Driver Side Airbag (운전석 에어백을 장착한 중형 트럭의 승객거동해석을 위한 유한요소 모델의 개발)

  • 홍창섭;오재윤;이대창
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.220-225
    • /
    • 2000
  • This paper develops a finite element model for studying occupant behavior of a mid-size truck equipped with a driver side airbag. The developed model simulates an occupant behavior using PAM-CRASH/PAM-SAFE in super computer SP2. The model is developed based on a sled test. A 50% hybrid dummy III is used for measuring head and chest accelerations and femur loads, and major injury coefficients such as HIC, CA and femur load. Inferior components such as foot rest, seat, kneebolster, crash pad, etc. are roughly modeled and defined by a rigid material model. And contact type II is used for detecting a contact with dummy. Contact type II definition uses force-deflection relationship of each body Such components as steering column which directly affect on the occupant injuy are modeled in detail and defined by an elastic-plastic material model. Airbag cushion is modeled using rivet elements. Airbag cover groove is modeled using rivet elements. Airbag tether is modeled as nonlinear bar elements. Airbag model has two vent holes to ventilating the exploded gas. Airbag is folded close to the real airbag folding procedure, and folded cautiously in order not to have initial penetration. A vehicle pulse acquired from 31mph frontal barrier test is used as input signal for the simulation. The simulation conditions are tuned to the sled test ones. The measured dummy accelerations and major injury coefficients, and filmed dummy behavior and airbag inflation process using high speed camera are compared to the simulation results to verify the developed finite element model.

  • PDF

A STUDY ON THE STABILITY OF IMPLANT SCREW BY USE OF THE SEALER (Sealer의 사용이 임프란트 나사의 안정성에 미치는 영향)

  • Lee Heung-Tae;Kim Nak-Hyung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.366-375
    • /
    • 2001
  • The objective of this study was to investigate the surface contact and screw joint stability between screw and implant interface by use of sealer. The implants evaluated in this study were Steri-Oss futures(Hexlock $3.8D{\times}10mm$: Steri-Oss, Yorba Linda, CA), and Steri-Oss staight abutment. Titanium alloy screws were used to secure abutments to implants. The other titanium alloy screws applicating sealer(Impla-Seal, Implant Support Systems, Inc. Irvine, CA) were used to secure abutments to implants. In one another sample, 6kg of force was applied during simulated intraoral movements after abutment screws were secured to the implants with sealer. All samples were cross sectioned with sandpaper and polished with $0.1{\mu}m\;Al_2O_3$. Then samples were recorded with an scanning electron microscope. The results were as follows : 1. In the case of titanium alloy screw, irregular contacts and relatively large gap were present at thread mating surface. Also abutment screw/implant interface demonstrate incomplete seating and only one surface contact of threads between implant and screw. 2. In the case of titanium alloy screw applecating sealer, sealer was present between implant and screw. Therefore implant and screw had relatively close and tight contact without the presence of large gap. 3. On the other hand, in the case of titanium alloy screw applicating sealer and dynamic loading of suprastructures, sealer was partially present between implant and screw. Conclusively, sealer fills voids, creating a barrier to moisture and bacteria. In addition, loading of suprastructures may change the situation and limit the indications for gap sealing.

  • PDF

A PHOTOMETRIC STUDY OF THE CONTACT BINARY XZ LEONIS

  • Lee Jae-Woo;Lee Chung-Uk;Kim Chun-Hwey;Kang Young-Woon
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.41-50
    • /
    • 2006
  • We present the results of new multi-color CCD photometry for the contact binary XZ Leo, together with reasonable explanations for the period and light variations. Six new times of minimum light have been determined. A period study with all available timings confirms Qian's (2001) finding that the O-C residuals have varied secularly according to $dP/dt\;=\;+8.20{\times}10^{-8}\;d\;yr^{-l}$. This trend could be interpreted as a conservative mass transfer from the less massive cool secondary to the more massive hot primary in the system with a mass flow rate of about $5.37{\times}10^{-8}\;M_{\odot}\;yr^{-l}$. By simultaneous analysis of our light curves and the previously published radial-velocity data, a consistent set of light and velocity parameters for XZ Leo is obtained. The small differences between the observed and theoretical light curves are modelled by a blue third light and by a hot spot near the neck of the primary component. Our period study does not support the tertiary light but the hot region which may be formed by gas streams from the cool secondary. The solution indicates that XZ Leo is a deep contact binary with the values of q=0.343, $i=78^{\circ}.8$, ${\Delta}(T_1-T_2)=126\;K$, and f=33.6 %, differing much from those of Niarchos et al. (1994). Absolute parameters of XZ Leo are determined as follows: $M_1=1.84\;M_{\odot},\;M_2=0.63\;M_{\odot},\;R_1=1.75\;R_{\odot},\;R_2=1.10\;R_{\odot},\;L_1=7.19\;L_{\odot},\;and\;L_2=2.66\;L_{\odot}$.

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

Physicochemical properties, cytotoxicity and penetration into dentinal tubules of sodium hypochlorite with and without surfactants

  • Hernan Coaguila-Llerena;Isadora Barbieri ;Mario Tanomaru-Filho ;Renato de Toledo Leonardo;Ana Paula Ramos ;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.47.1-47.11
    • /
    • 2020
  • Objectives: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCidTM Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCidTM (3% NaOCl without surfactant). Materials and Methods: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). Results: ChlorCidTM Surf and ChlorCidTM FAC values were close to those indicated by the manufacturer. ChlorCidTM Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCidTM (p < 0.05). The penetration of ChlorCidTM Surf was higher in cervical and middle segments, compared with ChlorCidTM (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). Conclusions: ChlorCidTM Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCidTM. However, both solutions showed similar cytotoxicity and FAC content.

Adsorption Properties of the Lysozyme and Albumin with Physicochemical Properties of the Contact Lens (콘택트렌즈의 물리화학적 특성에 따른 라이소자임과 알부민의 흡착 특성)

  • Sung, Yu-Jin;Ryu, Geun-Chang;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.261-270
    • /
    • 2013
  • Purpose: Adsorption properties of lysozyme and albumin according to physiochemical properties of commercial contact lens classified with the FDA categories and a contact lens fabricated in the laboratory were investigated. Methods: The contact lens were prepared using HEMA(2-hydroxyethyl methacrylate) and TRIM(3-(trimethoxysilyl) propyl methacrylate) in a cast mold. Artificial tears containing lysozyme and albumin were prepared. We measured the amounts of protein adsorbed on the each lenses with varying adsorbed time (48 hour) and the pH range (6, 6.8, 7.4, 8.2, 9) of artificial tear. Amount of the proteins absorbed on the contact lenses were measured by using HPLC. Results: Time to reach the equilibrium of protein adsorption for silicone hydrogel lens was taken longer than hydrogel lens. The amount of adsorbed both lysozyme and albumin at equilibrium were greater for the hydrogel lens than the silicone hydrogel lens, and larger for the ionic lens than the non-ionic lens. Lysozyme was more adsorbed on the higher water content of contact lens, whereas albumin was more adsorbed on the lower water content of contact lens. Only lysozyme was adsorbed on the Group IV hydrogel lens of ionic higher water content. The adsorption of protein on contact lens increased with pH of artificial tears as close to the isoelectric point of each protein. Conclusions: The adsorption amount of lysozyme is more affected by the ionic strength of the contact lens surface than the water content of contact lens. Albumin adsorption is more affected by water content than the ionic strength of the contact lens surface. For the adsorption of proteins on the silicone hydrogel lens, the pore size, determined both by the number of Si atoms and the chemical structure of the silicone-containing monomers, as well as the polarity of contact lens should be also considered.

Clinical Significance of Interferon $\gamma$ Release Assay for Diagnosis of Tuberculosis in Children (소아 결핵 진단에 있어서 결핵 특이항원자극 인터페론 감마 측정검사의 임상적 의의)

  • Lee, Hee Woo;Park, Hwa Young;Ahn, Young Min;Sohn, Keun Chan
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.137-147
    • /
    • 2010
  • Purpose : The purpose of this study is to evaluate the usefulness and limitation of QuantiFERON-TB Gold (QTB) for diagnosis of latent tuberculosis in children. Methods : The medical records of 112 children who were tested by tuberculin skin test (TST) and QTB for detection of latent tuberculosis (TB) in Eulji General Hospital during the period from January 2007 to June 2009 were retrospectively reviewed. Results : Of the 112 participants, the clinical TB group included 15 (13.4%), the contact group included 43 (38.4%), and the non-contact group included 54 (48.2%). Positive rates of TST and QTB were 100% and 80% in the clinical TB group, 64% and 14% in the close contact group, 27% and 0% in the casual contact group, and 52% and 2% in the non-contact group, respectively. Sensitivity of QTB was 80.0% and specificity was 92.6%. Agreement between QTB and TST was poor ($\kappa$=0.209). We also confirmed that the positive rate of QTB increased as the age of the patient increased (P=0.011). A QTB indeterminate result was observed in 11 (9.8%) subjects. QTB was retested in 15 subjects. In 5 of the 6 subjects who had positive results initially, positive results persisted for a median 2.2 months after termination of treatment. Conclusion : Although QTB was associated with several problems, including low sensitivity and a high rate of indeterminate results, it had clinical importance due to its high specificity. We found good correlation with regard to exposure and QTB positivity, including that of young children under 5 years of age. However, clinical application of interferon-$\gamma$ releasing assay for young children for diagnosis of active and latent tuberculosis will require additional prospective studies.

Finite Element Analysis of Reinforced Concrete Masonry Infilled Frames with Different Masonry Wall Thickness Subjected to In-plane Loading (채움벽 두께에 따른 철근콘크리트 조적채움벽 골조의 면내하중에 대한 유한요소해석)

  • Kim, Chungman;Yu, Eunjong;Kim, Minjae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.85-93
    • /
    • 2016
  • In this study, finite element analyses of masonry infilled frames using a general purpose FE program, ABAQUS, were conducted. Analysis models consisted of the bare frame, infilled frames with masonry wall thickness of 0.5B and 1.0B, respectively. The masonry walls were constructed using the concrete bricks which were generally used in Korea as infilled wall. The material properties of frames and masonry for the analysis were obtained from material tests. However, four times increased the tensile strength was used for 1.0B wall, which is seemingly due to the differences in locating the bricks. The force-displacement relation and development of crack from the FE analysis were very similar to those from the experiments. From the FEA results, contact force between the frame and masonry, distribution of shear force and bending moments in frame members were analyzed. Obtained contact stress shows a trianglur distribution, and the contact length for 0.5B speciment and 1.0B specimen were close to the value estimated using ASCE 41-06 equation and ASCE 41-13 equation, respectively. Obtained shear force and bending moment distribution seems to replicate actual behavior which originates from the contact stress and gap between the frame and masonry.

Development of the Inductive Proximity Sensor Module for Detection of Non-contact Vibration (비접촉 진동 검출을 위한 유도성 근접센서모듈 개발)

  • Nam, Si-Byung;Yun, Gun-Jin;Lim, Su-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.61-71
    • /
    • 2011
  • To measure the fatigue of metallic objects at high speed vibration while non-contact precision displacement measurement on how to have a lot of research conducted. Noncontact high-speed vibration detection sensor of the eddy current sensors and laser sensors are used, but it is very expensive. Recently, High-speed vibrations detection using an inexpensive inductive sensor to have been studied, but is still a beginner. In this paper, a new design of an inexpensive inductive proximity sensor has been suggested in order to measure high frequency dynamic displacements of metallic specimens in a noncontact manner. Detection of the existing inductive sensors, detection, integral, and amplified through a process to detect the displacement noise due to weak nature of analog circuits and integral factor in the process of displacement detection is slow. The proposed method could be less affected by noise, the analog receive and high-speed signal processing is a new way, because AD converter (Analog to Digital converter) without using the vibration frequency signals directly into digital signals are converted. In order to evaluate the sensing performance, The proposed sensor module using non-contact vibration signals were detected while shaker vibration frequencies from 30Hz to 1,100 Hz at intervals of vibrating metallic specimens. Experimental results, Vibration frequency detection range of the metallic specimins within close proximity to contactless 5mm could be measured from DC to 1,100Hz and vibration amplitude of the resolution was $20{\mu}m$. Therefore, the proposed non-contact inductive sensor module for precision vibration detection sensor is estimated to have sufficient performance.

Display of operating feel of virtual tool in frictional contact with elastically deforming environment (마찰을 고려한 탄성변형 환경과 접촉하는 가상도구의 조작감 제시)

  • Choi, Hyoukryeol;Lee, Seungryong;Ryew, Sungmoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.790-800
    • /
    • 1998
  • This paper presents a haptic rendering algorithm in the case that the virtual environment elastically deforms in response to the force applied by a user with a virtual tool. Considering friction, elasticity, multiple contacts and dynamics of the virtual object, this algorithm lets the operator have the feel of interactions in the virtual environment as close as to the reality. Based on the proposed algorithm several experiments are conducted and its effectiveness is confirmed.