• Title/Summary/Keyword: Clinical measurement method

Search Result 527, Processing Time 0.072 seconds

Relationship among Essentials of Fundamental Nursing Skills Performance, Stress from Work and Work Capability of New Clinical Nurses (신규간호사의 핵심기본간호술 수행과 업무스트레스 및 업무수행능력과의 관계)

  • Bang, Soon Sik;Kim, Il-Ok
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.20 no.4
    • /
    • pp.628-638
    • /
    • 2014
  • Purpose: This study identifies the relation among the essentials of fundamental nursing skills performance (EFNSP), work capability and stress from work experienced by new clinical nurses. Method: This is a cross-sectional descriptive study with a self-reported questionnaire. The subjects were 224 new clinical nurses employed by general hospitals having more than 400 beds. The data, collected from February 10 to March 7, 2014, were analyzed using descriptive statistics, t-tests, ANCOVA, Pearson's correlation analysis and hierarchical linear regression. Results: The highest frequency of EFNSP of new clinical nurses was vital sign measurement (4.74, ${\pm}.89$) and the lowest frequency of performance was Basic CPR & defibrillator application (1.81, ${\pm}.94$). There were significant positive correlations between frequency and confidence of EFNSP (r=.64, p<.001), frequency and work capability (r=.34, p<.001), and confidence of EFNSP and work capability (r=.48, p<.001), but negative correlation stress from work and work capability (r=-.17, p=.009). General characteristics, stress from work, frequency and confidence in EFNSP and stress from work explain 25.1% of work capability. Conclusion: This result suggests the importance of EFNSP education in nursing schools and availability of opportunities to practice EFNSP during the post-graduation waiting period until assignment to a hospital.

Spectrofluorimetric Determination of Bisphosphonates in Biological Sample with a Fluorescent Chemosensor, NadDPA-2Zn2+

  • Jeong, Yun-Seong;Kim, Soon-Young;Jin, Geun-Woo;An, Song-Hie;Lee, Jae-Han;Jeong, A-Reum;Chio, Yeon-Soon;Hong, Jong-In;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2561-2564
    • /
    • 2010
  • The accurate determination of bisphosphonate levels in bone and biological fluids is important in both clinical and pharmacological/toxicological studies; however, the quantitative analysis of the bisphosphonate is difficult because its concentration is quite low in most of biological sample. A novel fluorescent chemosensor (FCS)-based measurement method of bisphosphaonate levels using Naphta-diDPA-$2Zn^{2+}$ (NadDPA-$2Zn^{2+}$, DPA = dipycolylamine), an excellent FCS previously used for detecting PPi, was developed. By the FCS method, the concentration of bisphosphonates having no fluorophores can be determined analyzed with sufficient sensitivity. The results of this study indicate that the FCS-based measurement can be a useful method to analyze bisphosphonates in biological samples.

Measurement of Physician's Work for Korean Medicine Services Using Analytic Hierarchy Process (계층화 분석법(Analytic Hierarchy Process)을 활용한 한의사 업무량 산출)

  • Lim, Byung-Mook;Kwon, Hyuk-Sang;Han, Chang-Ho;Shin, Byung-Cheul
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.105-115
    • /
    • 2009
  • Background: The resource-based relative value scale has been applied to Korean medicine services as part of the National Health Insurance, yet the proper scoring method for physician's work needs to be developed. Objectives: To measure physician's work for Korean medicine services using Analytical Hierarchy Process(AHP) and to compare results abstracted by AHP with those by Magnitude Estimation method. Methods: We developed the AHP questionnaires for Korean Medicine services and administered it to 12 Korean medicine insurance experts. Weighted scores were calculated and were converted into physician's work scores. Results: In AHP measurement, the physician's work scores for acupuncture activities, especially special acupunctures, far increased, while those for diagnosis and basic consultations decreased. Variations in the scores enlarged. Conclusions: As an alternative, AHP method can be considered for measuring the physician's work for Korean medicine services with careful management of scoring variation.

  • PDF

EEG Recording Method for Quantitative Analysis (정량적 분석을 위한 뇌파 측정 방법)

  • Heo, Jaeseok;Chung, Kyungmi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.397-405
    • /
    • 2019
  • Quantitative electroencephalography (QEEG) has been widely used in research and clinical fields. QEEG has been widely used to objectively document cerebral changes for the purpose of identifying the electrophysiological biomarkers across various clinical symptoms and for the stimulation of specific cortical regions associated with cognitive function. In electroencephalography (EEG), the difference in quantitative and qualitative analyses is discriminated not by its measurement methods and relevant clinical or research environments, but by its analysis methods. When performing a qualitative analysis, it is possible for a medical technologist or experienced researchers to read the EEG waveforms to exclude artifacts. However, the quantitative analysis is still based on mathematical modeling, and all EEG data are included for the analysis, leading the results to be affected by unexpected artifacts. In the hospital setting, the case that the medical technologists in charge of the EEG test perform academic research has been little reported, compared to other clinical physiological measurement-based research. This is because there are few laboratories specialized in clinical physiological research. In this respect, this study is expected to be utilized as a basic reference material for medical technologists, students, and academic researchers, all of whom would like to conduct a quantitative analysis.

Development of EGG measurement system with running spectrum analysis (위전도 측정기의 개발 및 스펙트럼 분석)

  • Ryu, Chang-Yong;Kim, Su-Chan;Kim, Deok-Won;Lee, Sang-In
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.82-85
    • /
    • 1995
  • Electrogastrography(EGG) has been an attractive method for physiological and pathophysiological studies of the stomach and now is on the verge of becoming a new clinical tool in gastroenterology. In this study EGG measurement system was constructed and running spectrum analysis was developed for three-dimensional display of power spectrum with time. The noninvasive technique of EGG is an excellent alternative since the established invasive methods for the study of the stomachs of children and infants.

  • PDF

A Study on multifidus muscle activation by Needle EMG during shoulder flexion in Chronic Low Back Pain Patients (침 근전도로 측정한 만성 요통 환자의 어깨 굴곡시 나타나는 다열근 활성도 비교)

  • Jang, Won-Seok
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.3
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of study is activation of lumbar multifidus muscle by needle EMG during shoulder flexion in chronic low back pain patients. The subject were consisted of 10 women patients with chronic low back pain and healthy asymtomatic subject 10 women. Methods : 10 women patients with chronic low back pain and healthy asymptomatic subject 10 women is voluntary participated for the research. Subjects were positioned in standing. The needle EMG were measured activation of multifidus. Needle electrode was used to 28 gauge. The shoulder flexion movement used to activate the multifidus was then measured. Results : Results of the analysis showed that asymptomatic subjects had significantly larger multifidus muscle activation compared with CLBP subjects during shoulder flexion. Conclusion : This study will be used as multifidus measurement method of patient with chronic LBP. The multifidus muscle in chronic LBP patient clinical significance. Most of chronic LBP patients have multifidus contraction pattern. Therefore chronic LBP patients necessary multifidus activation measurement with needle EMG.

  • PDF

The Psychometric Properties of Distance-Digital Subjective Happiness Scale

  • Almaleki, Deyab A.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.5
    • /
    • pp.211-216
    • /
    • 2021
  • This study intended to test the structure of the latent factor of a subjective happiness scale and the stability of invariance across groups of students' classifications (gender and students' status). In the large, non-clinical sample (619), students completed the subjective happiness scale. The (CFA) confirmatory factor analysis was used to investigate the factor-structure of the measure, and multiple-group confirmatory factor analysis (MGCFA) model was used to test the stability of invariance across groups of students classifications. The findings of the CFA indicated support for the original one-factor model. Additional analyses of the MGCFA method support the measurement (configural, metric and strong) invariant and practical invariant components of this model. There was an invariant across gender. There was partially invariant across groups of students' statuses. The scale exists in both groups to assess the same concepts of (single and married), excluding Items 3 and 4. Given that this study is the first investigation for the structure of the subjective happiness scale.

The Psychometric Properties of Effectiveness Scale in Distance-Digital

  • Almaleki, Deyab A.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.12
    • /
    • pp.149-156
    • /
    • 2021
  • This study intended to test the structure of the latent factor of an effectiveness scale and the stability of invariance across groups of students' classifications (gender and levels of education). In the large, non-clinical sample (850), students completed the effectiveness scale. The (CFA) confirmatory factor analysis was used to investigate the factor-structure of the measure, and multiple-group confirmatory factor analysis (MGCFA) model was used to test the stability of invariance across groups of students' classifications. The findings of the CFA indicated support for the original four-factor model. Additional analyses of the MGCFA method support the measurement (configural, metric and strong) invariant and practical invariant components of this model. There was an invariant across gender. There was partially invariant across groups of levels of education. The scale exists in groups of levels of education assess the same concepts of, excluding Items 15 and 10. Given that this study is the first investigation for the structure of the effectiveness scale.

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

The basic investigation for the objective study on the pulsation (맥진의 현대적인 객관화 연구를 위한 기반조사 - I. 기계적 측정법에 대한 비교연구-)

  • Kim Gyeong Cheol;Shin Soon Shik;Kang Hee Jung;Cha Chul Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1147-1150
    • /
    • 2003
  • Modern Objectification of Pulse Diagnosis, One of the Four Diagnosis Method of Oriental Medicine, is necessarily project to improving Oriental medical clinic status and quality by standardization of diagnosis database. At that, accurate measurement equipment or devices(sensor, system and instruments, etc,) to exactly detect MacSang(脈診 : the parameter and subject of pulse diagnosis) have not developed yet. Existing Pulse diagnosis devices are not satisfy clinical needs and medical equipments quality. We study for pulse diagnosis system, that CD is satisfying oriental medical clinic needs, is ensuring accuracy and reappearance to support in clinical diagnosis and treatment, is guaranteeing the quality of medical equipments. theoretical base and convenience.