• Title/Summary/Keyword: Clinical Technologist

Search Result 90, Processing Time 0.024 seconds

Related Factors on the Blood Donation Experience among Healthcare Provider in a General Hospital (일개 종합병원 보건의료인의 헌혈경험 관련 요인)

  • Kong, Jung-Hee;Kim, Miyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2628-2638
    • /
    • 2015
  • The purpose of this study was to examine knowledge, attitude, and altruism on blood donation and influential factors in regard to its experience. Data were collected through questionnaires with a convenience sample of 311 healthcare providers. Subjects with blood donation experience accounted for 63.3%. In both nurses and laboratory technologist, the rate of blood donation in male group has higher than that of female group. There were differences in the knowledge of blood donation dependent upon the type of occupation of healthcare providers and the higher age and the longer period of career experience proved to be the significant factor for the level of altruism. The study suggests that more practical, concrete strategies should be identified to participate in blood donation. The further relevant variables need to be investigated since the most determinant motivator for blood donation among healthcare providers was the responsibility to help others.

Comparison of Demographic and Job Characteristics with Job Satisfaction between Sonographers and Radiological Technologists (초음파사와 방사선사의 인구학적 및 직무 특성과 직무 만족도의 비교분석)

  • Kim, Hye-Jin;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.389-397
    • /
    • 2021
  • The purpose of this study was to compare the demographic and job characteristics and job satisfaction of sonographers (SONO) and radiological technologists (RT). The subjects were a total of 148 people (69 SONO, 79 RT), who had been working in clinical and hospitals. The method was conducted using a questionnaire with a total of 54 questions consisting of demographic characteristics, job characteristics, and job satisfaction. Reliability was secured with Cronbach's alpha coefficient of 0.6 or higher for the response of the questionnaire. For statistical analysis, descriptive statistics, cross-analysis, independent sample T-test, and correlation analysis using Pearson's correlation coefficient and Spearman's correlation coefficient were performed for each occupation. As a result, first, the SONO had more female workers than RT. They are more than three times as many in graduate school and above. Second, the SONO had 4.5 times more morning shift than the RT and no form of weekend shift. Third, the average monthly salary of the SONO is higher than that of the RT, but when a certain portion of the salary goes up, the salary no longer goes up. Fourth, satisfaction with expectations, growth desire, positive mentality, growth opportunity, job importance, organizational attachment was higher SONO than the RT, but self-efficacy was higher in RT than SONO. Last, SONO had higher educational background than RT. It is hoped that the results of this study will be able to understand the job characteristics of SONO and RT and identify the factors of job satisfaction and provide them as fundamental materials for job selection.

An Estimation of the Efficiency and Satisfaction for EEG Practice Using the Training 10-20 Electrode System: A Questionnaire Survey (연습용 10-20 Electrode System을 이용한 뇌파검사 실습의 효율성과 만족도 평가)

  • Lee, Chang Hee;Kim, Dae Jin;Choi, Jeong Su;Lee, Jong-Woo;Lee, Min Woo;Cho, Jae Wook;Kim, Suhng Wook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.300-307
    • /
    • 2017
  • Electroencephalography (EEG) is distinct from other medical imaging tests in that it is a functional test that helps to diagnosis disorders related to the brain, such as epilepsy. The most important abilities for a medical technologist when performing an EEG are knowing the exact location of the electrode and recording the EEG wave clearly, except for artifacts. Although theoretical education and practical training are both included in the curriculum for improving these abilities, sufficient practical training has been lacking due to problems like expensive equipment and insufficient practical training time. We try to solve these issues by manufacturing the training 10-20 electrode system and by estimating the efficiency and satisfaction of the training 10-20 electrode system through a questionnaire. The time required for practical training using this system was $43.58{\pm}9.647min$, which proved to be efficient. The satisfaction score of participants who experienced curriculum practical training was improved from $7.21{\pm}2.285$ to $9.46{\pm}1.166$. Based on these findings, it is considered that practical training via the use of the training 10-20 electrode system will solve the problems, such as lack of equipment and insufficient practical training time. Nonetheless, to further improve the training 10-20 electrode system, it must overcome the limitations of developing a device capable of checking the actual brain waves and validating the exact location of electrode attachment.

Study on Development in Professional Work of Radiological Technologists (방사선사 업무의 발전에 관한 조사 연구)

  • Choi, Jong-Hak;Kim, Chang-Kyun;Kim, Won-Chul;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.197-210
    • /
    • 2006
  • This study explored several agenda related to license system, education, professional work of radiological technologists(RTs) and a transition process of law for them to investigate a developmental strategy of RTs as a professional career. The results are as followings : 1. The national license system for RTs was started from 1965, 1965-1972 x-ray technicians(medical assistance), 1973-present(2006) radiotechnologist(medical technologist) since then. 2. The average pass ratio of national license examination(1965-2006) for RTs was 46.6%. The method, subjects and level of the examination should be improved. 3. The education term for RTs has been changed since 1963 ; 1963-1990 two year college, 1991-1999 three year college, 2000-2006 four year and three year college depending on universities and colleges. As of 2006, there are twelve 4-year universities and eighteen 3-year colleges. The total number of new students were 1,956. 4. The new developmental paradigm should be made for technology education of RTs corresponding to the development of medicine and science. 5. The qualification system of clinical specialists in radio-technology field needs to be operated not by the non-governmental body(The Korean Radiological Technologists Association) but by the governmental body. 6. The vertical relationship among RTs, doctors and other medical workers should be rebuilt through the revision of law. Especially, doctors and dentists 'guidance authority' for RTs should be changed to 'request authority'. 7. The service extent of RTs should be extended in medical fields corresponding to professional work of RTs and a revision of the law needed for this situation.

  • PDF

Study on the Difference of Urine Sediment Preparation for Microscopic Examination (현미경검사를 위한 요침사 표본제작에 따른 차이 연구)

  • Lee, Hyeok-Jae;Park, Chul;Seo, Min-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.366-373
    • /
    • 2017
  • Urinalysis is considered to be easier and simpler than other tests. It has been known to cause no burden to patients, while offering important information on diagnosing, treating, and determining the prognoses of kidney and urinary tract diseases. Urinary sediments are usually performed by microscopic examination of centrifuged urine by technologist. The guidelines proposed by the Korean Association of External Quality Assessment Service are actually different from those actually practiced by medical institutions and taught to biomedical students in textbooks. Therefore, we verified whether different sediment preparation methods lead different test results. Specimens that tested positive from the occult blood and leukocyte esterase in the urine dipstick test were randomly selected for a microscopic examination. The differences in the urine sediment preparation affected the sediment concentrations, which influenced the cell grade and cell number per HPF. The first factor in determining the sediment concentration is the centrifugal force. Many medical institutions use 1,500 rpm as the centrifugal speed without considering the radius of the centrifuge; such a value may not be accurate for 400 G. Consequently, there were differences in urine concentrations, which influenced the results. The second factor is the amount of sediment in urine. Different amounts of the remaining supernatant led to different sediment concentration factors, again, causing different results. Furthermore, not only by using a pipette to obtain an accurate amount as stipulated, but also by roughly obtaining a drop, the microscopic examination using such a volume of sediment examined affected the results. Therefore, this study highlights the importance of standardization of urine sediment preparation procedures to promote consistency and accuracy across institutions.

The Evaluation of Non-Ionizing Radiation (Near-Infrared Radiation) based Medical Imaging Application : Diabetes Foot (비전리 방사선 (근적외선) 기반 의료영상 활용 가능성 평가: 당뇨발)

  • Jung, Young-Jin;Shin, Cheol-Won;Ahn, Sung-Min;Hong, Jun-Yong;Ahn, Yun-Jin;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.399-406
    • /
    • 2016
  • Near-infrared radiation (NIR) is non-ionizing, non-invasive, and deep tissue penetration in biological material, thereby increasing research interests as a medical imaging technique in the world. However, the use of current near-infrared medical image is extremely limited in Korea (ROK) since it is not well known among radiologic technologists and radiological researchers. Therefore to strengthen the knowledge for NIR medical imaging is necessary so as to prepare a qualified radiological professionals to serve medical images in high-quality on the clinical sites. In this study, an overview of the features and principles of NIR imaging was demonstrated. The latest research topics and worldwide research trends were introduced for radiologic technologist to reinforce their technical skills. In particular, wound care and diabetic foot which have high feasibility for clinical translation were introduced in order to contribute to accelerating NIR research for developing the field of radiological science.

Prospective Supply and Demand of Medical Technologists in Korea through 2030 (임상병리사 인력의 수급전망과 정책방향)

  • Oh, Youngho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.511-524
    • /
    • 2018
  • The purpose of this study is to provide policy recommendations for manpower planning by forecasting the supply and demand of Medical Technologists. Supply was estimated using an in-and-out movement method with a demographic method based on a baseline projection model. Demand was projected according to a demand-based method using the number of clinico-pathologic examinations taken for Medical Technologists. Over- or undersupply of Medical Technologists will depend on the productivity scenario and assumptions and ultimately on governmental policy direction. In other words, whether the production of Medical Technologists is higher or lower than the current level depends on the government policy to consider insurance finances. In this study, we assessed 'productivity scenario 3' based on the productivity as of 2012, when the government's policy direction was not considered. Based on the demand scenario using the ARIMA model, the supply of Medical Technologists is expected to be excessive. This oversupply accounts for less than 10% of the total and therefore should not be a big problem. However, given that the employment rate of Medical Technologists is 60%, it is necessary to consider policies to utilize the unemployed. These measures should expand the employment opportunities for the unemployed. To this end, it is necessary to strengthen the functions of laboratories in the public health center, to increase the quota of Medical Technologists, to assure their status, to establish a permanent inspection system for outpatient patients, and to expand the export of Medical Technologists overseas.

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

Comparison of Cardiac Size and Cardiac Thoracic Ratio in Pregnant and Non-pregnant Women of Normal Korean Women Using Chest X-ray (흉부 방사선검사 영상을 이용한 한국인 정상 여성의 임신기와 비 임신기 심장크기와 심흉비 비교)

  • Joo, Young-Cheol;Kim, Gyoo-Hyung
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.223-229
    • /
    • 2018
  • The purpose of this study is to present the reference values for cardiac size and cardiothoracic ratio change, normal range and diagnosis of cardiovascular disease in pregnancy and non pregnancy of normal Korean women using chest X-ray. The subjects of this study were 58 women, who were read as normal by chest radiologist, had chest radiography taken on both last month of pregnancy, pre-pregnancy and within 2 years following delivery. In this study, we defined the last month of pregnancy as pregnancy and before or post pregnancy as non-pregnancy. CS and CTR were measured by two radiological technologist who had clinical experience more ten years with Danzer's method. Statistical methods were paired t-test and one-way ANOVA. Significance level ${\alpha}$ was 0.05 and p-value 0.05 or less was statistically significant. For pregnancy, the mean of left and right cardiac size was $40.11{\pm}8.73mm$ and $89.51{\pm}11.9mm$, CS was $128.60{\pm}13.15mm$, CTR was $44.51{\pm}4.21%$. In non pregnancy, $36.50{\pm}8.18mm$ and $77.68{\pm}13.1mm$. CS and CTR were $114.18{\pm}14.28mm$ and $42.03{\pm}4.04%$. Both pregnancy and non pregnancy, the difference of the mean value in left and right cardiac size, CS and CTR were statistically significant (p<0.01). but comparing mean on age, height and weight, the difference of the mean value between groups was not (p>0.05). In the result of this study, the mean size of CS increased by 12.6% in pregnancy($128.60{\pm}13.15mm$) compared to the non pregnancy($114.18{\pm}14.28mm$), and increased by 9.8% in the right side of the heart and 15.2% in the left side. The mean size of CTR increased about 5.9% in pregnancy ($44.5{\pm}4.21%$) compared to non pregnancy($42.03{\pm}4.04%$).

The Usefulness of Video Fluoroscopic Swallowing Study in Post-Stroke Dysphagia Patients (뇌졸중 후 연하장애 환자에서 비디오 투시 연하 조영검사의 유용성)

  • Eun, Sung-Jong;Kim, Sung-Gil;Hong, Jea-Ran
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.19-25
    • /
    • 2010
  • Dysphagia is common and serious problems in post-stroke patients. The post-stroke dysphagia with aspiration is associated with dehydration, malnutrition, pneumonia, sepsis and death. Up to date, gag reflex and choking history used to decide the aspiration in clinical. The purpose of this study was to evaluate the aspiration and to choice the proper meal formation using by video fluoroscpic swallowing study(VFSS) with post-stroke dysphagia patients. 58 post-stroke patients and ten normal person participated to perform the VFSS with liquid type, puding, yoplait, rice mixed with barium(Ba). Two rehabilitation medicine doctors and a radiological technologist analysed the phase(oral, pharyngeal, esophageal phase)with video film, and checked the pharyngeal transition time(PTT). 38 patients showed abnormality in pharyngeal phase, 13 patients in oral and pharyngeal phase, 3 patients in oral phase, and 2 patients in pharyngeal and esophageal phase. 43 patients(65.2%) occured the aspiration, but 23 of 43 patients improved by the chin tuck position. Aspiration occured 34 patients in liquid type, 2patients in rice gruel and nothing in boiled rice. After VFSS, 13 of 23 patients change the intaking pathway from nasogastric tube(NGT) to oral, On the contrary with 3 of 42 patients from oral to NGT. Consequently VFSS is clearly effective to evaluate the aspiration with post-stroke dysphagia patients.