• Title/Summary/Keyword: Clinical Crown

Search Result 379, Processing Time 0.025 seconds

Full mouth Rehabilitation with Orthognathic Surgery in Facial Asymmetry Patient : Case Report (안면 비대칭환자의 악교정 수술을 동반한 완전구강회복)

  • Im, So-Min;Shin, Hyoung-Joo;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.359-371
    • /
    • 2010
  • Facial asymmetry has been found with a higher frequency (70~84%) in skeletal class III malocclusion patients. Anticipating the poor prognosis of prosthesis due to malocclusion, occlusal stability must be obtained by orthodontic treatment. Moreover, orthodontic surgery would be needed in some severe cases for better functional and esthetic results. The orthognathic surgery is performed on one jaw or two jaw depending on the results of facial diagnosis. Genioplasty may change the vertical, horizontal, sagittal position of chin by osteotomy or augmentation using implants, also. This case is about a 24 year-old male patient who visited our clinic to solve the facial asymmetry and mandibular prognathism. Skeletal class III malocclusion, maxillary canting and menton deviation to left by 13 mm were detected. Multiple ill-fitting prostheses, unesthetic maxillary anterior prostheses, and several dental caries were found. After pre-operative orthodontic treatment, Le-Fort I osteotomy, sagittal split ramus osteotomy, genioplasty, right mandibular angle augmentation were done for the correction of jaw relation and asymmetry. By diagnostic wax-up after post-operative orthodontic treatment, maxillary full mouth rehabilitation and mandibular posterior restorations were planned out. For better result, clinical crown lengthening procedure was done on #11, 12 and implant was placed on left mandibular first molar area. The patient was satisfied with the final prostheses. Because of his high caries risk, long-term prognosis will depend on the consistent maintenance of oral hygiene and periodic follow-up.

Effect of a Pulsed Nd:YAG laser irradiation on human gingival tissues (파동형 Nd:YAG 레이저조사가 인체 치은조직에 미치는 영향)

  • Kang, Kyung-Dong;Kim, Chun-Suk;Kim, Hyung-Soo;Kim, Hyun-Seop;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.989-1002
    • /
    • 1996
  • The purpose of this study was to determine the effect of a pulsed Nd:YAG laser irradiation on human gingival tissues. The patients, who were planned to be treated by clinical crown lengthening procedure and gingivectomy, were selected. All the patients received oral hygiene instruction, scaling and root planing at preoperation. The crest of gingival tissue on upper and lower anterior teeth was irradiated by a pulsed Nd:YAG laser(El. EN. EN060, Italy) with a fiber optic of 300 m in contact mode for 20 seconds. Gingival tissues were divided into 4 groups according to the laser power of 1.0W(10Hz, 100mJ), 2.0W(20Hz, 100mJ), 3.0W(30Hz, 100mJ) and 4.0W(40Hz, 100mJ). Immediately after the laser irradiation, the specimens were excised, fixed 10% neutral formalin, sectioned $4-6{\mu}m$ thick, stained by Hematoxylin-Eosin and Periodic Acid Schiff stain and observed under light microscope. The removed tissue depth and the coagulated layer depth due to a laser irradiation by a laser irradiation were measured on the microphotographs. The difference of measurements according to the different laser power was statistical1y analyzed by Kruskal Wallis Test with SAS program. The results were as follows : 1. In histologic findings of irradiated gingival tissues; a. In the irradiated gingival specimen with 1.0W laser power, some vesicles were observed in limited superficial layer of gingival epithelium. b. In the irradiated gingival specimen with 2.0W and 3.0W laser power, the epithelium was almost removed except for the traces of viable basal cell remnants at ret peg, and coagulation necrosis related with the thermal effect of laser was noted. c. In the irradiated gingival specimen with 4.0W laser power, complete removal of epithelium, partial removal of underlying connective tissue, and the coagulation necrosis of subjacent gingival tissue were shown. 2. The removed tissue depth was deeper in the irradiated specimens with higher power. There was a statistical significance in the difference of removed tissue depth between 1.0W group ($44.54{\pm}6.99um$) and 3.0W group ($99.75{\pm}6.64{\mu}m$), and between 1.0W group($44.54{\pm}6.99{\mu}m$) and 4.0W group($111.36{\pm}4.50{\mu}m$), and between 2.0W group($98.01{\pm}4.53{\mu}m$) and 4.0W group($111.36{\pm}4.50{\mu}m$)(P<0.05). 3. The coagulated layer depth was deeper in the irradiated specimens with higher power. There was a statistical significance in the difference of coagulated layer depth between 1.0W group($31.82{\pm}8.99{\mu}m$) and 3.0W group($55.99{\pm}20.94{\mu}m$), and between 1.0W group($31.82{\pm}8.99{\mu}m$) and 4.0W group($83.68{\pm}10.34{\mu}m$)(P<0.05). From this study, the results demonstrated that the effects of a pulsed Nd:YAG laser irradiation on gingival tissues seemed to depend on the laser power and that the irradiation with high power could be harmful to adjacent healthy tissue.

  • PDF

AN EPIDEMIOLOGIC STUDY ON THE PEDIATRIC PATIENTS IN DEPARTMENT-OF PEDIATRIC DENTISTRY, CHOSUN UNIVERSITY DENTAL HOSPITAL FOR LAST 10 YEARS(1990-1999) (최근 10년간 조선대학교 치과병원 소아치과에 내원한 신환에 관한 역학적 연구(1990-1999))

  • Ryu, Hyun-Seop;Kim, Hyo-Suck;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.345-354
    • /
    • 2001
  • The purpose of this study was to make public oral health plan more effective and the improvement of the hospital management system for better clinical dental practice. Distribution and trends were examined in all patients who had been examined and diagnosed at Department of Pedodontics, Dental Hospital, Chosun University over 10 year-period from 1990 to 1999 Results were as follows, 1. The number of patients per year was increasing trend after 1996 and higher visiting rate in male(55.9%) than in female(44.1%). 2. Age distribution had shown $3\sim4$ year-old cup being the largest (23.4%) and each percentage of $5\sim6,\;7\sim8,\;0\sim2,\;9\sim10,\;11\sim12,\;13\sim14,\;above\sim15$ year-old group was 19.9%, 17.7%, 14.6%, 12.6%, 8.0%, 3.3%. 0.5%. 3. Geographic distribution showed a majority of patients in Kwang-Ju (83.0%). Group in the suburbs of Kwang-Ju(Jang-Sung group) was 5.4%. 4. Dental caries showed the highest percentage(40.5%) in chief complaints and percentage of oral exam, orthodontic problem, oral pain, trauma, supernumerary teeth, swelling was 13.9% 12.6%, 8.8%, 7.4%, 5.5%, 4.9%. 5. In all patients with traumatic problem, crown fracture showed the highest percentage(41.4%) and percentage of subluxation was 19.4%. 6. Majority(78.7%) of patients were not refered, and percentage of patients refered from local clinic was 20.5%. 7. Patients who had periodic check-up comprised 19.6%, and percentage of after 3, 6, 9, 12, 18, 24month was 36.7%, 22.2%, 13.5%, 11.3%, 5.4%, 11.0%.

  • PDF

A STUDY ON THE FEATURES OF MESIODENS AND THE RESOLUTION RATE OF COMPLICATIONS AFTER THE EXTRACTION OF MESIODENS (상악 정중부 과잉치의 양상과 발거 후 병발증 치유율에 관한 연구)

  • Jun, Eun-Min;Kim, Tae-Wan;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.268-277
    • /
    • 2008
  • Authors evaluated 1171 patients at the department of Pediatric Dentistry in Kyoungpook National University Hospital through clinical records and radiographs. And the following features were studied ; age, sex distribution, number of mesiodens per patients, cause of discovery of mesiodens, location, status of eruption, shape and orientation of crown, complication, dental age of adjacent upper incisor tooth at the time of surgical extraction of mesiodens and the relationship between the resolution rate of complication after extraction of mesiodens and the dental age of adjacent upper incisor tooth, length of diastema, the eruption status of lateral incisor and the crowding status of premaxilla. The followings are the results : 1. The cause of discovery of mesiodens were as follows ; delayed eruption of the permanent incisors in 13.8%, midline diastema in 11.6%, radiographs taken for other reasons in 23.4% and for caries treatment in 15.1%. 2. Complication due to the presence of mesiodens did not occur in 36.8%, delayed eruption of adjacent teeth was observed in 16.1%, midline diastema in 34.4%, rotation in 8.8%, displacement in 2.4%, and crowding in 1.0% of all evaluated patients. 3. As for the dental age of adjacent upper incisor tooth at the time of surgical extraction of mesiodens, below 1/3 of total root length were observed in 3.5%, $1/3{\sim}1/2$ of total root length in 19.9%, $1/2{\sim}2/3$ of total root length in 54.7% and over 2/3 in 21.9% of all evaluated patients. 4. Resolution rate of delayed eruption after the extraction of mesiodens was significant higher in the group with the root length below 1/2. Resolution rate of midline diastema was significant higher in the group with diastema width below 3mm and with non-crowding of adjacent upper incisor teeth.

  • PDF

A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core (주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향)

  • Nam, Ki-Young;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The purpose of this study was to compare the microleakage at the interface of cast post and tooth according to the type of cement. Forty anterior teeth with single root were used. The teeth were cut 2 mm coronal from the cementoeamel junction and chamfer finish line was made on 1 mm coronal from the cementoeamel junction. After the routine endodontic treatment, post space was prepared using #5.5 Parapost drill to a depth of 7 mm. After the pick up impression, core building was made to 3 mm of clinical crown with burnout wax, then post and core was cast with nonprecious metal. The teeth were divided into four groups of ten each. In Group I, post and core were cemented with Fleck's(Zinc phosphate cement) In Group II, post and core were cemented with Fuji I(Glass ionomer cement) In Group III, post and core were cemented with Superbond C & B(Composite resin cement) In Group IV, post and core were cemented with Panavia 21(Composite resin cement) All cemented teeth were stored in normal saline at $37^{\circ}C$ for 7 days and thermocycled from $5^{\circ}C$ to $55^{\circ}C$ for 500 cycles with a dwell time of 30 seconds. After thermocycling, teeth were immersed in 1% Basic fuchsin dye for 48 hours. All 40 teeth were then embedded in the epoxy resin and cut buccolingually with a cutting instrument. The degree of penetration of dye at interface was graded on a scale of 0 to 4 using a stereomicroscope at 25 to 40 times magnification. Through the findings of this study, the following conclusion were obtained. 1. All the groups showed the microleakage at the interface of cast post core and tooth. 2. Group I showed the highest microleakage score among the groups with a significant difference(p<0.05). 3. Group II showed higher microleakage score than Group III and Group IV with a significant difference(p<0.05). 4. Group IV showed the lowest microleakage score but there were no significant difference with Group III(p>0.05).

  • PDF

Influence of additional etching on shear bond strength of self-etching adhesive system to enamel (부가적인 산부식이 자가산부식 접착제의 법랑질에 대한 전단결합강도에 미치는 영향)

  • Yoo Sun-Jin;Kim Young-Kyung;Park Jeong-Won;Jin Myoung-Uk;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.263-268
    • /
    • 2006
  • Recently, self-etching adhesive system has been introduced to simplify the clinical bonding proce- dures. It is less acidic compared to the phosphoric acid, thus there is doubt whether this system has enough bond strength to enamel. The purpose of this study was to investigate the influence of additional etching on the adhesion of resin composite to enamel. Ninety extracted bovine permanent anterior teeth were used. The labial surfaces of the crown were ground with 600-grit abrasive paper under wet condition. The teeth were randomly divided into six groups of 15 teeth each. Clearfil SE $Bond^{\circledR},\;Adper^{TM}$ Prompt L-Pop and Tyrian $SPE^{TM}$ were used as self-etching primers. Each self-etching primers were applied in both enamel specimens with and without additional etching. For additional etching groups, enamel surface was pretreated with 32% phosphoric acid (UNI-ETCH, Bisco, Inc., Schaumburg, IL. USA). Hybrid resin composite Clearfil AP-X, (Kuraray Co., Ltd., Osaka, Japan) was packed into the mold and light-cured for 40 seconds. Twenty-four hours after storage, the specimens were tested in shear bond strength. The data for each group were subjected to independent t - test at p < 0.01 to make comparisons among the groups. In Clearfil SE $Bond^{\circledR}$, shear bond strength of additional etching group was higher than no additional etching group (p < 0.01). In $Adper^{TM}$ Prompt L-Pop and Tyrian SPE, there were no significant difference between additional etching and non-etching groups (p > 0.01). In conclusion, self-etching adhesive system with weak acid seems to have higher bond strength to enamel with additional etching, while self-etching adhesive system with strong acid seems not.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Evaluation of static fracture resistances and patterns of pulpless tooth restored with poly-ether-ketone-ketone (PEKK) post (Poly-ether-ketone-ketone (PEKK) 포스트로 수복한 근관 치료 치아의 정적 파절 저항성 및 파절 형태에 관한 평가)

  • Park, Ha Eun;Lee, Cheol Won;Lee, Won Sup;Yang, Sung Eun;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.127-133
    • /
    • 2019
  • Purpose: The purpose of present study was to investigate fracture strength and mode of failure of endodontically treated teeth restored with metal cast post-core system, prefabricated fiber post system, and newly introduced polyetherketoneketone (PEKK) post-core system. Materials and methods: A total of 21 mandibular premolar were randomly grouped into 3 groups of 7 each according to the post material. Group A was for metal cast post core; Group B for prefabricated glass fiber post and resin core; and Group C for milled PEKK post cores. All specimens were restored with metal crown. The fracture strength of each specimen was measured by applying a static load of 135-degree to the tooth at 2 mm/min crosshead speed using a universal testing machine. After the fracture strength measurement, the mode of failure was observed. The results were analyzed using Kruscal-Wallis test and post hoc Mann-Whitney U test at confidence interval ${\alpha}=.05$. Results: Fracture resistance of PEKK post core was lower than those of cast metal post and fiber reinforced post with composite resin core. In the aspect of fracture mode most of the root fracture occurred in the metal post core, whereas the post detachment occurred mainly in the fiber reinforced post. In the case of PEKK post core, teeth and post were fractured together. Conclusion: It is necessary to select appropriate materials of post for extensively damaged teeth restoration and clinical application of the PEKK post seems to require more research on improvement of strength.

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF