• 제목/요약/키워드: Cleansing

Search Result 277, Processing Time 0.023 seconds

Comparison of Cleansing Regimes for Efficacy and Comfort of Iontophoretic Transdermal Lidocaine Delivery (세정방법에 따른 국소마취제 이온도입의 효율과 편안감 비교)

  • Jeong, Myung-A;Song, In-Yong;Lee, Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.4
    • /
    • pp.41-50
    • /
    • 2006
  • Purpose: The purpose of this study was to determined that the efficacy and comfort of iontophoretic transdermal delivery of lidocaine by comparison of local anesthetic duration, sensory threshold, pain threshold and pain tolerance levels according to four different cleansing regimes. Methods: Forty healthy volunteers were randomly assigned to four groups; oil cleansing group, lotion cleansing group, solution cleansing group and alcohol cleansing group. All subjects were received lidocaine iontophoresis on the forearm using direct current with 4 mA for 10 minutes. All subjects were measured the duration of local anesthesia after lidocaine iontophoresis, also evaluated the sensory threshold, pain threshold and pain tolerance level during iontophoresis. For comparisons of the efficacy and the sensory characteristics of iontophoresis within the groups, an one-way ANOVA was used. Results: The duration of local anesthesia were found significant difference between groups (p<0.001). The anesthetic duration in solution and alcohol cleansing groups were significantly longer than oil and lotion cleansing group by post hoc (p<0.05). Statistically significant difference were noted in respect to all sensory characteristics such as sensory threshold, pain threshold and pain tolerance between groups (p<0.001). The sensory threshold in solution and alcohol cleansing group were significantly lower than oil and lotion cleansing group by post hoc using Duncan multiple range test (p<0.05). The pain threshold and pain tolerance in solution and alcohol cleansing group were significantly higher than oil and lotion cleansing group by post hoc (p<0.05). Conclusion: These results demonstrated that cleansing regimes have affected the efficacy and discomfort of iontophoretic transdermal delivery of lidocaine. These findings indicate that cleansing agents without oil ingredient contributed to more comfort, and more successful achievement of the iontophoretic transdermal delivery.

  • PDF

Preparation and Evaluation of Cosmetic Tissue using W/Si/W Multiple Emulsion (실리콘 다중유제 (W/Si/W)를 이용한 화장용 티슈의 개발 및 평가)

  • Han, Sang-Chul;Park, Duck-Sang;Shin, Jae-Hong;Kim, Tae-Hyeon;Park, Jeong-Sook;Cho, Cheong-Weon;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.4
    • /
    • pp.217-222
    • /
    • 2007
  • To develop cleansing tissue composed of silicone multiple emulsions which could easily remove make-up residues and confer skin protecting effect without damaging skin, we formulated various silicone multiple emulsions and evaluated the physicochemical properties including viscosity, cleansing effect, and safety effect. Also, cleansing tissue incorporated with silicone multiple (W/Si/W) emulsion was stored for 6 months, and judged its stability through microscopes under accelerated and long-term condition. Cleansing effect was evaluated by chromameter. Skin hydration effect was determined by corneometer and incorporation effect into non-woven fabric cotton was evaluated by volunteer survey. Low viscosity ranged from 400 centipoise (cP) to 1,000 cP was obtained from a stabilized W/Si/W emulsion containing more than 10% volatile silicone. Mean diameter of fresh W/Si/W emulsion was $20{\mu}m$, but after storage for 3 months at $45^{\circ}C$, the particle size of the W/Si/W emulsion increased up to $50{\mu}m$. Both W/Si/W emulsion-incorporated cleansing tissue and commercial product showed equally good cleansing effect. In addition, skin allergies such as erythema, edema, scaling itching, stinging, burning, tightness and prickling were not observed through macroscopic examination. From the transepidermal water loss results, the cleansing tissue consisting of W/Si/W emulsion showed superior hydration effect to commercial product. In conclusion, this study suggests cleansing tissue using W/Si/W emulsion could be used for an excellent efficacy compared with commercialized cleansing tissue.

Activation of Stripper Solution by Plasma and Hardness/Modulus of Elasticity Change of the Surface (Plasma를 이용한 세정액의 활성화와 시료 표면의 탄성계수 및 강도 변화에 대한 연구)

  • Kim, Soo-In;Kim, Hyun-Woo;Noh, Seong-Cheol;Yoon, Duk-Jin;Chang, Hong-Jun;Lee, Jong-Rim;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • In the modem semiconductor industry, the progress that consumes the most capital and labor is cleansing process. Cleansing process is to remove impurities that can affect the operation of the device and deteriorate its function. Especially, Photoresist (PR) progress that etches the device always requires cleansing at the end of the progress. Also, HDI-PR (High-Dose Ion-implanted Photoresist) created from PR progress is difficult to remove. Thus, in modem IC cleansing, many steps of cleansing are used, including dry and wet cleansing. In this paper, we suggested to combine existing dry-cleansing and wet-cleansing, each represented by plasma cleansing and stripper solution, as Plasma Liquid-Vapor Activation (PLVA). This PLVA method enhances the effect of existing cleansing solution, and decreases the amount of solution and time required to strip. We stripped HDI-PR by activated solution and measured surface hardness and Young's modulus by Nano-indenter. Nano-indenter is the equipment that determines the hardness and the modulus of elasticity by indenting nano-sized tip with specific shape into the surface and measuring weight and z-axis displacement. We measured the change of surface hardness and Young's modulus before and after the cleansing. As a result, we found out that the surface hardness of the sample sharply decreased after the cleansing by plasma-activated PR stripper solution. It can be considered that if physical surface-cleansing process is inserted after this, more effective elimination of HDI-PR is possible.

The Effect of Atmospheric Plasma Parameters on Cleansing the Electronic-Industrial Parts (상압 플라즈마 매개변수들이 산업용 전자부품의 세척공정(cleansing)에 미치는 효과)

  • Ri, Eui-Jae
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.208-215
    • /
    • 2009
  • We employed atmospheric plasma to reactively remove the lubricant sprayed onto such industrial electronic parts as LCD chassis during sheet-metal forming processes and investigated basically the effect of plasma parameters on cleansing the surfaces of zinc-electroplated steel plates (EGI). Specimen prepared with some controlled amount of lubricant sprayed on their surfaces beforehand were subjected to two different kinds of atmospheric plasma, one being generated by using air and the other generated by using nitrogen (99.9% purity). Locating the plasma beams at the height range between 3.5 and 13.5 mm from the surface of each specimen and radiating for 5 to 30 seconds resulted out that the cases with a position of 3.5 mm and a duration of 5 seconds or longer showed the surfaces completely cleansed without a trace of lubricant. Furthermore we found out that the plasma generated by using simple air depicted higher cleansing ability than the other one generated by using expensive nitrogen, interestingly useful very much for industrial purposes. On another aspect, we confirmed that the drilled or cut surfaces of Zn-plated steel substrate would not be oxidized even under the influence of plasma during its cleansing process. Therefore, we could probably conclude from this fore-survey that a dry process adopting atmospheric plasma for cleansing industrial parts might be determined to become successful in terms of commercialization, cautiously.

The Efficacy of Cleansing Device with a Rotating Brush on the Skin (회전 브러시를 이용한 클렌징 기기의 효과)

  • Yeo, In Kwon;Suk, Jang Mi;Jung, Sang Wook;Park, Jin Oh;Kim, Eun Joo;Nam, Gae Won;Yoo, Kwang Ho;Kim, Beom Joon;Kim, Myeung Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.97-103
    • /
    • 2013
  • Recently, the importance of cleansing is emphasized according to increasing use of cosmetics. Even though many cleansing devices with a rotating brush are commercially available, there are no reports about cleansing devices with rotating brushes in Korean literature. In the present study, we evaluated the efficacy of cleansing device with a rotating brush which was named PBRCF1201 (Amorepacific Co., Korea). 20 volunteers were enrolled in this study. Before and after use of PBRCF1201, we measured the number of black head, skin brightness, desquamation index, sebum, and the number of pores on the face and forearm. Cleansing by cleansing device with a rotating brush was shown to cleanse better than manual cleansing. In addition, the number of black heads, skin brightness, desquamation index, sebum and the number of pore were also improved after cleansing. Therefore, the cleansing device with a rotating brush appears to be an effective cleansing method without causing injury or dryness.

The Effects of Cleansing oil on Skin by preferred Vegetable Base oil (선호하는 식물성 Base oil에 따른 클렌징 오일이 피부에 미치는 영향)

  • Kim, Jung-Eun;Lee, Jae-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.264-274
    • /
    • 2019
  • This study attempted to analyze the effects of cleansing oil on skin by preferred vegetable base oil. For this, a questionnaire survey was performed against 100 people, and their face washing habit and preferred vegetable base oils were examined. Based on the results, 4 different cleansing oils were prepared and experimented. The experiment was conducted against 10 adult women in their 20-30s, and moisture level, sebum level and trans-epidermal water loss (TEWL) before and after the experiment were measured. After the test, satisfaction was measured, and the results found the followings: When asked what cleansing oil is most preferred by vegetable base oil type, 'rose hip oil' was the highest, followed by 'olive oil', 'apricot kernel oil' and 'camellia oil'. According to the clinical trials, both moisture and sebum levels increased before and after cleansing in all four cleansing oil types by the preferred vegetable base oil (p<0.001, p<0.001). In addition, TEWL decreased with a difference by base oil (p<0.01). According to a subjective satisfaction survey which was performed after the experiment, rose hip oil-contained cleansing oil (RHC) was the highest in terms of cleansing effect and satisfaction level. Consequently, it was confirmed that the cleansing oil by vegetable base oil improved skin conditions by protecting a skin barrier with a positive effect on the improvement of sebum and moisture levels and TEWL. Even though a preferred oil type and a satisfaction level may differ by preferred oil and feeling after use, cleansing oil by vegetable base can be helpful as a skin care product which eases skin dryness and protects a skin barrier.

Lead Adsorption by Carboxylated Alginic Acid and Its Application in Cleansing Cosmetics (Carboxylated Alginic Acid 및 이를 함유한 세정용 화장품의 납 흡착 효과)

  • Park, Hee-Yeon;Jang, Mi-Soon;Kadnikova, Irina;Kim, Yeon-Kye;Lim, Chi-Won;Yoon, Ho-Dong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.5
    • /
    • pp.400-405
    • /
    • 2010
  • This study investigated lead adsorption by carboxylated alginic acid and its application in cleansing cosmetics. Carboxylated alginic acid showed the highest lead adsorptivity after oxidation in a 4-6 mM hydrogen peroxide solution at $20-30^{\circ}C$ for 30-40 min. Carboxylated alginic acid adsorbed $648.1{\pm}2.8-653.0{\pm}2.9$ mg/g of lead dry mass at pH 4-6. Carboxylated alginic acid modified by hydrogen peroxide and potassium permanganate adsorbed $651.3{\pm}3.8$ and $639.9{\pm}4.0$ mg/g of lead dry mass, respectively. Carboxylated alginic acid showed higher lead adsorptivity after modification by hydrogen peroxide than by potassium permanganate, with an increase of ~30% compared with raw alginic acid. To access the potential application of carboxylated alginic acid in cleansing cosmetics, we investigated the lead adsorptivity, conditions of the cosmetics procedure, and cytotoxicity of various concentrations of cleansing cosmetics added to 5% carboxylated alginic acid. The ideal cosmetic concentrations combined with 5% carboxylated alginic acid were 70% for peeling gel, 20% for massage cream, 20% for foam cleansing and 40% for cleansing cream. There was no cytotoxicity in cleansing cosmetics combined with 5% carboxylated alginic acid.

Denture Cleansers (의치세정법)

  • Hwang, Jung-Won;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.244-249
    • /
    • 1997
  • Proper hygienic care of removable dentures is an important means of maintaining a healthy oral mucosa on denture wearers. Denture cleansing is often poor due to improper mechanical and the inefficient chemical cleansing of dentures. Dentists and patients should realize that microbial plaque on dentures may be harmful to both the oral mucosa and the patient's general health. This literature review was aimed to evaluate materials and methods for cleansing dentures and to discuss different means of keeping dentures plaque-free. A routine denture cleansing regimen should be designed to remove and prevent reaccumulation of microbial plaque and also to remove mucin, food debris, calculus, and exogenous discoloration. The combined use of chemical and mechanical cleansing is highly recommended for patients to clean their denture effciently.

  • PDF

CLEANSING EFFECT OF AIR-DRIVEN SONIC SYSTEM IN ROOT CANAL PREPARATION (공기진동(空氣振動) 근관형성법(根管形成法)의 근관정화효과(根管淨化效果))

  • Kim, Yong-Duk;Cho, Kyew-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.253-263
    • /
    • 1988
  • In order to study the cleansing effect of air-driven sonic system, the author prepared root canals on 48 extracted human permanent single rooted teeth using hand instrumentation and aforementioned method, half and half of the cases. In order for comparison of the degree of remnant debris and cleanliness, the cross sections at 3mm and 7mm levels from the apex were stereomicroscopically observed and scored in accordance with predetermined degree. The obtained results were as follows: 1. Air-driven sonic system was more effective in cleansing root canal than hand instrumentation at apical 3mm level. (p < 0.01) 2. Air-driven sonic system was more effective in cleansing root canal than hand instrumentation at apical 7mm level. (p < 0.01) 3. In hand instrumentation, Helisonic file was more effective in cleansing root canal than Rispisonic file. (p < 0.05) In air-driven sonic system, on the other hand, there were no significant difference between the two files.

  • PDF

Plaque Removing Efficacy and Effect on Gingival Inflammation of Newly Developed Tooth Cleansing Instrument (새롭게 개발된 치아청결기의 치태제거 및 치은염증에 대한 효과)

  • Han, Dong-Kwan;Pang, Eun-Kyung;Kim, Chan-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.475-484
    • /
    • 2003
  • Many tooth cleansing instruments and agents have been developed for removal of plaque, inhibition of plaque formation and reduction of gingival inflammation. The aim of this study was to evaluate the plaque control effect and the therapeutic effect of newly developed tooth cleansing instrument(Belloblanco(R)). 40 healthy subjects with gingivitis or early periodontitis were divided into two groups. Subjects in control group only used manual tooth brushing and in experimental group used manual tooth brush and additive tooth cleansing instrument(Belloblanco(R)). Additive tooth cleansing instrument was used once a week. At baseline scaling and tooth brushing instruction was performed. Probing depth, bleeding on probing, plaque index, gingival index were scored at baseline, 2weeks, 4weeks. Probing depth of control and experimental group were significantly reduced at 2 weeks, 4weeks, hut there were no differences between two groups(P<(0.05). Bleeding on probing, plaque index and gingival index of control and experimental group were significantly reduced at 2weeks and 4weeks and there was significantly more reduction in the experimental group than the experimental group than the control group(p<(0.05). From these finding. it can be conclude that newly developed tooth cleansing instrument(Belloblanco(R)) are effective on the removal of plaque and the reduction of gingival inflammation