Field Applications of Carbon Dioxide Pellet for Underground Pipe Cleaning (지중 매설관의 세정을 위한 카본 다이옥사이드 펠릿의 현장 적용성 검토)

  • Choi, Jae-Soon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.75-82
    • /
    • 2017
  • In this study, a new cleaning method using carbon dioxide pellet in the part of underground pipe cleaning method was proposed and verified. First of all, the commentary of The Society for Protective Coatings was examined in detail to determine the quantitative cleaning effects. Also, field tests were carried out to confirm the application of the new method. In the test, the surface condition of inner pipe after the application of the new method was investigated and two types of nozzles were compared in the tests. Also, the tests to measure the final impact pressure of air and carbon dioxide pellet mixtures were performed to investigate the losses of air pressure were investigated. Through this verification on the new method, it was found that the new method is very efficient for the removal of the rust in the pipe cleaning works. Also, the nozzle with excellent cleaning effect was also selected. As a result, this method will be able to largely contribute to the recycling of $CO_2$ which is limited to the use as a cooling agent or the storage of waste.

Development of a Monitoring System for a Pipe Cleaning Robot with RS-485 (RS-485 통신을 이용한 배관청소 로봇의 모니터링 시스템 개발)

  • Kim, Min-wook;Lee, Hun-seok;Oh, Jin-seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.923-930
    • /
    • 2016
  • Various pipes are used in the many industrial field such as water supply, drainage system and marine plants, so a maintenance of these pipes is essential. Especially, the maintenance of the piping in the industrial field, some professional staffs enter and clean the pipe. If the professional staffs can not enter and clean the pipe, the workers has to use the method of inserting a scraper connected to wire inside the pipe. However, this method demands huge budget and causes a number of problems such as traffic congestion. To solve these problems, pipe cleaning robot has been researching and developing. Many Pipe cleaning robots have a problem, that is impossible to confirm the operating condition of the robot in a real time. This paper suggest pipe cleaning robot with RS-485 which transmit operating and cleaning condition of robot and inner pipe filmed by camera, that user can check.

Chemical cleaning effects on properties and separation efficiency of an RO membrane

  • Tu, Kha L.;Chivas, Allan R.;Nghiem, Long D.
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.141-160
    • /
    • 2015
  • This study aims to investigate the impacts of chemical cleaning on the performance of a reverse osmosis membrane. Chemicals used for simulating membrane cleaning include a surfactant (sodium dodecyl sulfate, SDS), a chelating agent (ethylenediaminetetraacetic acid, EDTA), and two proprietary cleaning formulations namely MC3 and MC11. The impact of sequential exposure to multiple membrane cleaning solutions was also examined. Water permeability and the rejection of boron and sodium were investigated under various water fluxes, temperatures and feedwater pH. Changes in the membrane performance were systematically explained based on the changes in the charge density, hydrophobicity and chemical structure of the membrane surface. The experimental results show that membrane cleaning can significantly alter the hydrophobicity and water permeability of the membrane; however, its impacts on the rejections of boron and sodium are marginal. Although the presence of surfactant or chelating agent may cause decreases in the rejection, solution pH is the key factor responsible for the loss of membrane separation and changes in the surface properties. The impact of solution pH on the water permeability can be reversed by applying a subsequent cleaning with the opposite pH condition. Nevertheless, the impacts of solution pH on boron and sodium rejections are irreversible in most cases.

A Selection of the Optimal Working Condition for an Outer-hull Preprocessing Robot Using a Taguchi Method (다구찌 방법을 이용한 선체 외판 전처리 로봇의 최적 작업 조건 선정)

  • Chung Won-Jee;Kim Ki-Jung;Kim Hyo-Gon;Kim Jung-Hyun;Kim Ho-Kyung;Lee Hun-Dong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.4
    • /
    • pp.69-73
    • /
    • 2006
  • This paper present the optimal cleaning condition of the out-hull preprocessing robot by Taguchi method in design of experiments. A $L_8(2^4)$ orthogonal array is adopted to study the effect of adjustment parameters. The adjustment parameters consist of robot speed, motor torque, motor speed and tool angle. And the quality feature is selected as surface roughness of sheet metal. Taguchi analysis is performed in order to evaluate the effect of adjustment parameters of the quality feature of cleaning process by $Minitab^{(R)}$.

Investigation on DHF Application at Metal CMP Cleaning Process (Metal CMP 세정 공정에서 DHF 적용에 관한 연구)

  • 김남훈;김상용;김인표;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.569-572
    • /
    • 2003
  • In this study, we evaluated the dilute HF cleaning to reduce residual defects made by metal CMP process. The purpose of this test is to observe the existence of barrier metal damage during DHF cleaning on condition that it should not affect metal thin film reliability, so we will get rid of slurry residual particles as a main defect of the metal CMP process for the better yield. In-line defect data showed us that slurry residual particles were removed by DHF application. The HF rinse significantly reduced metal contamination levels and surface roughness. The best effect by additional oxide loss was discovered when Dilute HF condition is 10".

Improving the Fading of Reusable Surgical Gown by Repeated Severe Laundering and Sterilization Condition (반복되는 고온 세탁 및 멸균 환경에 대한 Reusable 수술가운 원단의 퇴색 저항성 개선 연구)

  • Kim, Ji Yeon;Min, Mun Hong;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.215-222
    • /
    • 2013
  • The purpose of this study is to minimize fading fabrics of surgical gown by repeated severe laundering and sterilization condition. The study showed that the best conditions were reduction cleaning using sulphinic acid derivatives or glucose organic chemicals at $98^{\circ}C$ alkaline solutions. In these conditions, color difference values(dE) were below 1.0 that means unrecognizable color change by repeated laundering and sterilization. If it treated with only laundering, reduction cleaning conditions may adjust over $80^{\circ}C$ alkaline solution. In conclusion, it is needed to select the high-washing fastness dye and reduction cleaning using sulphinic acid derivatives or glucose organic chemicals at $98^{\circ}C$ alkaline solutions for removal unfixed dyes.

A Study on the Cleaning Efficiency Valuation of Alternatives Cleaning Agent for Trichloroethane & Trichlorotrifluoroethane (Trichloroethane과 Trichlorotrifluoroethane의 대체세정제에 대한 세정력 평가에 관한 연구)

  • Lee, Seok-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 1996
  • Many alternatives to Trichlorothane & Trichlorotrifluoroethane mainly used as cleaning solvent for industrial parts are developed and commercialized because the solvent is scheduled to phaseout after 1996. Considering there are many kinds of parts and contaminants in all parts cleaning, It is essential to investigating the characteristics and performance of the alternatives prior to use. For the contaminant of a standard oil, waters, hydrocarbon and halogen parts which are the comercially available and promising alternatives were experimented at the same condition of Trichlorothane & Trichlorotrifluoroethane to check the cleaning performance. Overally, the removal efficiency of halogen solvent parts was better than that of hydrocarbon or waters parts for removing the standard oil used in this experiment.

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.