• 제목/요약/키워드: Cleaner

검색결과 673건 처리시간 0.025초

진공청소기 팬 모터의 진동 및 소음원인 분석을 위한 유동해석 (The Flow Analysis for Vibration and Noise Diagnostic of Vacuum Cleaner Fan Motor)

  • 김재열;곽이구;안재신;양동조;송경석;박기형
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.56-63
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

진공청소기용 원심팬 주위의 유동해석을 통한 성능개선 (THE PERFORMANCE IMPROVEMENT OF VACUUM CLEANER BY ANALYSIS OF THE FLOW AROUND CENTRIFUGAL FAN)

  • 박진우;기민철;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.82-87
    • /
    • 2007
  • A cleaner has trouble with too much noise and power consumption. To solve these problems, the investigation for motors, which are the main component of vacuum cleaner, is required. However, it is difficult to analyze the flow by the experimental means because of the high speed of the fan rotation ranging from 30,000 rpm to 50,000 rpm. Moreover it takes much time to perform the numerical simulation for the flow. In this research, it is aimed to analyse the flow through the centrifugal fan which is believed to be a main noise source, by the computational method. The efficiency of the centrifugal fan is affected by friction loss, shock loss and so on. Those losses depend on factors like the velocity of impeller, blade shape and etc. Accordingly, the influence of the shape of impeller on the flow is investigated in this study. The computational analysis was done by changing impeller shapes. The flow around the centrifugal fan is simulated by applying the moving mesh. To verify the validity of the computation results, the air flow rate and the pressure field to the cleaner is compared with the experimental data. All simulations are performed by using commercial code SC/Tetra. The calculated results show good agreement with the experimental ones qualitatively and it is believed to be promising to use computational simulation in the improvement of the vacuum cleaner performance.

  • PDF

실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구 (A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System)

  • 구정환;김성찬;김장우;이주용;이재근;강태욱;이감규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

3차원 레이저 진동 측정기를 이용한 초고속 진공청소기 모터의 진동특성분석 (The Analysis of Vibration characteristics for Vacuum Cleaner Fan Motor Using 3-D Laser Vibrator)

  • 김재열;김우진;심재기;김영석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.399-405
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000 rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

  • PDF

공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향 (Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation)

  • 이천환;김민영;이수민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.77-82
    • /
    • 2023
  • The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.

혀 세정기가 부착된 수동칫솔이 치아와 혀의 세정도 및 구취 관리도에 미치는 영향 (The effect of tongue cleaner-equipped manual toothbrush on tooth and tongue cleanness and malodor index)

  • 김태일;홍삼표;이신재;강봉선;오영상;김인경;오미현
    • Journal of Periodontal and Implant Science
    • /
    • 제38권4호
    • /
    • pp.699-708
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the effect of tongue cleaner-equipped manual toothbrush on tooth cleanness, tongue cleanness and malodor index. Materials and methods: 504 subjects were included in this study. At 1st visit, basic information such as age, sex, smoking amount and alcohol consumption was recorded. Self assessment by individual subjects was performed regarding satisfaction to old toothbrush and toothbrushing habit. Tooth cleanness, tongue cleanness and malodor index was assessed by professional researcher. Tongue cleaner-equipped manual toothbrush was given to each subject with proper toothbrushing instruction. After 1 month passed, self assessment and researcher assessment regarding the same index were performed and analyzed statistically by chi-square test. Results: At 1st visit subjects seem to ignore tongue cleansing and showed poor tooth cleanness index, tongue cleanness index and malodor index, however the same subjects were motivated to clean their tongue and teeth and presented statistically improved distribution pattern in tooth cleanness index, tongue cleanness index and malodor index after using tongue cleaner-equipped manual toothbrush(p<0.01). Satisfaction to tongue cleaner-equipped manual toothbrush was 98%. Conclusion: Tongue cleaner-equipped manual toothbrush would be an effective tool for maintaining good oral hygiene through improving tooth and tongue cleanness and preventing malodor formation.

전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계 (Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology)

  • 권경석;이인복;황현섭;;홍세운;서일환;최지선;송상현;문운경
    • 한국농공학회논문집
    • /
    • 제52권3호
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구 (Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation)

  • 이철민;김윤신;이태형;김종철;김중호
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

프로폴리스함유 천연구강청결제의 구강환경변화에 대한 임상적 연구 (Oral environmental change in the natural oral cleaner containing propolis)

  • 최우양;이지연;정화영;임근옥;정상희
    • 한국치위생학회지
    • /
    • 제15권2호
    • /
    • pp.319-324
    • /
    • 2015
  • Objectives: The purpose of this study was to verify the oral environmental change in using the natural oral cleaner containing propolis and prevention effect of oral disease. Methods: The subjects were 60 university students in Gangwon province. The groups consisted of 30 students of experimental group and 30 students of control group. The subjects were those who did not take the antipsychotic, diuretic, antihistamine, and anesthetic. The students rinsed their mouth with propolis mixture of oral cleanser for 4 weeks after receiving informed consent from October 1 to November 2, 2012. Collected saliva was measured for amount, salivary consistency, pH, plague index, gingival index, and halitosis. Results: The amount of salivary in propolis mixture of oral cleansing group remarkably increased (t=2.16, p<0.05). pH was alkaline in the group with oral cleaner containing the propolis (t=2.80, p<0.01). The bad breath remarkably decreased in the group with oral cleaner containing the propolis (t=-5.77, p<0.001). Conclusions: The use of the oral cleaner containing the propolis increased the amount of salivary and pH. The use of oral cleaner containing the propolis reduces halitosis and maintains good quality of oral hygiene.

Comparison of the physical characteristics according to the varieties of perilla for the development of a high-quality, high-efficiency cleaner and stone separator

  • Park, Jong Ryul;Park, Heo Man;Park, Hye Rin;Yang, Gye Hoon;Lee, Jung Hyun
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.717-726
    • /
    • 2020
  • The physical characteristics of the major varieties of perilla were analyzed to use as basic data for the design of a high-quality, high-efficiency perilla cleaner and stone separator. Because the size, thousand-grain weight, angle of repose, angle of friction, bulk density and terminal velocity of perilla have significant differences according to the perilla variety, the different of characteristics by variety should be considered for performance improvement of a perilla cleaner and stone separator. Therefore the cleaner and stone separator using a sieve could be improved by the application of a detachable sieve or by using equipment such as a 2 - 3 stage sieve and regulating the slope. Moreover, because differences in the terminal velocity occur due to the differences in the size and thousand-grain weight according to the perilla variety, a blower with an adjustable fan speed was considered for the design of the improved cleaner. Additionally, it was shown that the length of perilla has the greatest correlation based on a comparison of the coefficients of the other characteristics. Accordingly, the length of perilla could be used as a major factor for the fine adjustment and parts replacement of the device. These results can be used as basic data for a high-quality, high-efficiency perilla cleaner and stone separator. In the future, the development of the machine and follow-up studies based on the basic data are needed to determine the optimized operating conditions and mechanism of action.