• 제목/요약/키워드: Class II cavity restoration

검색결과 31건 처리시간 0.027초

유한요소법을 이용한 2급 복합레진 와동의 비교 연구 (A STUDY ON CLASS II COMPOSITE RESIN CAVITY USING FINITE ELEMENT STRESS ANALYSIS)

  • 임영일;여인호;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.428-446
    • /
    • 1997
  • Restorative procedures can lead to weakening tooth due to reduction and alteration of tooth structure. It is essential to prevent fractures to conserve tooth. The resistance to fracture of the restored tooth may be influenced by many factors, among these are the cavity dimension and the physical properties of the restorative material. The placement of direct composite resin restorations has generally been found to have a strengthening effect on the prepared teeth. It is the purpose of this investigation to study the relationship between the cavity isthmus and the fracture resistance of a tooth in composite resin restorations. In this study, MO cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method and isthmus(1/4, 1/3, 1/2 of intercuspal distance) were varied. Two types of model(B and R model) were developed. B model was assumed perfect bonding between the restoration and cavity wall and R model was left unfilled. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as follows : 1. Displacement of buccal cusp in R model occurred and increased as widening of the cavity, and displacement in B model was little and not influenced by cavity width. 2. There was a significant decrease of stress resulting in increase of fracture resistance in B model when compared with R model. 3. With the increase of the isthmus width, B model showed no change in the stress and strain. In R model, the stress and strain increased both in the area of buccal-pulpal line angle and the buccal side of marginal ridge, therefore the possibility of crack increased. 4. The stress and strain were distributed evenly on the tooth in B model, but in R model, were concentrated on the buccal side of the distal marginal ridge and buccal-pulpal line angle, therefore the possibility of fracture increased.

  • PDF

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향 (EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • 저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

  • PDF

광중합 시 수종의 심미적 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VARIOUS ESTHETIC RESTORATIVE MATERIALS AND BASES DURING CURING PROCEDURE)

  • 장혜란;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.393-398
    • /
    • 2001
  • Polymerization of light-activated restorations results in temperature increase caused by both the exothermic reaction process and the energy absorbed during irradiation. Within composite resin, temperature increases up to 2$0^{\circ}C$ or more during polymerization. But, insulation of hard tissue of tooth lowers this temperature increase in pulp. However, many clinicians are concerned about intrapulpal temperature injury. The purpose of this study was to evaluate temperature changes in the pulp according to various restorative materials and bases during curing procedure. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece fissure bur. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn below restorative materials for evaluating of temperature changes. This thermocouple was connected to temperature-recording device(Multiplication analyzer MX, 6.000, JAPAN). Temperature changes was evaluated from initial 37.$0^{\circ}C$ after temperature changes to 37.$0^{\circ}C$. Tip of curing unit was placed in the center of prepared cavity separated 1mm from restorative materials. Curing time was 40s. The restorative materials were used with Z 100, Fuji II LC, Compoglass flow and bases were used with Vitrebond, Dycal. Resrorative materials were placed in 2mm. The depth of bases were formed in 1mm and in this upper portion, resin of 2mm depth was placed. This procedure was performed 10 times. The results were as follows. 1. All the groups showed that the temperature in pulp increased as curing time increased 2. The temperature increase of glass ionomer was significantly higher than that of Resin and Compomer during curing procedure (P<0.05). 3. The temperature increase in glass ionomer base was significantly higher than that of Calcium hydroxide base during Resin curing procedure (P<0.05).

  • PDF

12세 이하 아동의 제1대구치 복합레진 수복의 재수복률에 관한 연구 (Repair Rate of Composite Resin Restorations in Permanent First Molar in Children Under 12 Years Old)

  • 정윤영;남옥형;김미선;이효설;최성철
    • 대한소아치과학회지
    • /
    • 제45권3호
    • /
    • pp.370-377
    • /
    • 2018
  • 이번 연구의 목적은 12세 이하의 아동의 제1대구치 복합레진 수복물에 관하여 후향적 연구를 하여 재수복률을 평가하고자 함에 있다. 이번 연구는 2014년 5월부터 2015년 4월까지 경희대학교 치과병원 소아치과를 내원하여, 제1대구치에 복합레진 수복을 진행한 12세 이하의 환자 169명의 재수복률과 그 원인을 분석하였다. 재수복률은 성별에 따라 통계적으로 유의한 차이는 보이지 않았다. 제1대구치의 위치에 따라서 상악보다는 하악이 그리고 우측보다는 좌측에서 재수복률이 높았다. 와동의 종류에 따라서 2급 와동에서 가장 재수복률이 높았고, 교합면만 수복한 경우 재수복률이 가장 낮았다. 2년간의 재수복률은 14.8%로 나타났으며, 연령이 증가함에 따라 재수복의 위험도는 감소하였다. 재수복의 가장 주된 원인은 이차우식(74.1%)이었다. 아동의 영구치 복합레진 수복물의 재수복률은 성인 보다 높은 것으로 나타났으며, 영구치의 맹출도, 환자의 협조도 및 구강위생 관리능력이 중요한 영향을 미치는 것으로 사료되었다.

치아 와동의 복합레진 수복시 음향방출의 시간적 발생 특성 (Time-Based Characteristics of Acoustic Emission During Dental Composite Restoration)

  • 구자국;최낙삼
    • 대한기계학회논문집A
    • /
    • 제35권2호
    • /
    • pp.169-174
    • /
    • 2011
  • 제 1 급 와동이 모사된 비관통형 치아 시편에 수복된 복합레진의 중합 수축시 발생하는 AE 신호를 실시간으로 검출한 후 이를 분석하였다. 시간대별 발생 분포를 살펴보면, 광조사 초기에 중합 수축이 급격히 진행되는 제 I 구간에서 AE event 가 많이 관찰되었다. 제 I구간 후 AE event 발생 빈도가 낮아져 AE 가 별로 관찰되지 않은 제II구간이 있었는데, AE 신호의 발생이 적은 PMMA 는 치아에 비해 구간이 길었으며 AE 검출이 잦았던 스테인리스스틸 모형은 제 II 구간이 짧았다. AE 활성도를 나타내는 구간 특성은 수복재와 와동의 계면부에서 일어나는 균열의 발생빈도를 나타내는 것으로 사료되며 젤화점 직후의 제I 구간에서 AE 가 집중적으로 관측되는 바, 수복재와 와동 사이의 갭 형성은 바로 젤화점 직후에 만들어졌음을 가리킨다. 신호의 최대 진폭은 25-45dB 이었고 1 차 중심 주파수는 100-200kHz 와 240-400kHz 영역의 신호들이 발생하였으며 이는 레진이나 접착층의 파괴에 해당하였다.

CAD/CAM으로 제작된 세라믹 인레이의 변연 및 내면 적합성 (MARGINAL AND INTERNAL FIT OF CAD/CAM-MANUFACTURED CERAMIC INLAY)

  • 손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.618-629
    • /
    • 1998
  • CAD/CAM-fabricated ceramic restorations nowadays are used as alternatives of amlagam and posterior composite resin restorations, especially in the cases of inlay restorations. But the reported results on marginal and internal fit of CAD/CAM-fabricated ceramic inlay have showed considerable difference. In this study, to evaluate the marginal and internal fit of CEREC2-fabricated ceramic inlay restoration and to compare with the fit of gold inlay and amalgam restoration, standardized Class II MO cavities were prepared in forty extracted caries-free human premolars. The teeth with prepared cavities were divided into 4 groups of ten teeth each. In group 1, CEREC2-fabricated ceramic inlays were treated with Scotchbond Multi-Purpose Plus(SMP plus) and cemented with Scotchbond Resin Cement. In group 2, casted gold inlays were cemented in the same method as in group 1. In group 3, casted gold inlays were cemented with zinc-phosphate cement. And in group 4, the prepared cavities were restored with amalgam. Restored teeth were thermocycled, stored in 1% methylene blue for 24 hours, and sectioned faciolingually and mesiodistally using EXAKT. Sectioned surfaces were observed with stereomicroscope and the gaps were measured at 9 points of mesiodistally sectioned surface and 7 points of faciolingually sectioned surface. The measured data were treated by Kruskal-Wallis one way ANOVA and Student-Newman-Keuls test. 1. The differences among measured gaps at each points were statistically significant for 4 experimental groups (P<0.05). 2. There were statistically significant differences in the measured gaps at each points between group 1 and group 2, group 1 and group 3, group 1 and group 4, group 2 and group 4, and group 3 and group 4 (P<0.05). 3. There were not statistically significant differences in the measured gaps at each points between group 2 and group 3 (P>0.05). 4. In the cases of inlay restorations(group 1, group 2, group 3), the gaps at internal line angle(distopulpal, axiogingival, faciopulpal, linguopulpal line angle) had a tendency to increase. In the cases of amalgam restorations(group 4), the gaps at occlusal margin, gingival margin and axiogingival line angle were greater than those at the other parts of cavities. 5. In CEREC2-fabricated ceramic inlays which were treated with Scotchbond Multi-Purpose Plus and cemented with Scotchbond Resin Cement, the mean gaps were $111{\mu}m$ at cavity margins, $168{\mu}m$ at vertical walls of cavities, $225{\mu}m$ at internal line angles and $123{\mu}m$ at cavity floors.

  • PDF

박스 형태의 복합레진 수복시 충전법 및 와동벽에 따른 결합력 차이에 관한 연구 (DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION)

  • 고은주;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.350-355
    • /
    • 2009
  • 복합 레진은 중합되는 동안 수축으로 인한 응력이 발생하게 되고 이는 결합력 실패를 야기한다. 치질과의 결합력은 접착면의 성질에 영향을 받게 되는데 대부분의 연구들은 편평한 접착면상에서 이루어졌으며 와동내 와벽 위치에 따른 결합력 차이에 관한 연구는 미미한 실정이다. 이에 본 연구에서는 Ⅰ급 복합레진 수복시 단일 충전한 경우와 적층 충전한 경우에 있어서 와동의 치수벽과 측벽에서의 결합력 차이를 알아보고자 하였다. 발거된 20개의 건전한 제3 대구치를 대상으로 6 ${\times}$4 ${\times}$3 mm 크기의 박스 형태로 와동을 형성한 후 레진 충전방법과 와동벽에 따라 4개 군으로 분류하였다. 단일 충전하고 치수벽의 결합력을 측정한 A군, 단일 충전하고 측벽의 결합력을 측정한 B군, 적층 충전하고 치수벽의 결합력을 측정한 C군, 적층 충전하고 측벽의 결합력을 측정한 D군으로 설정하였다. 제조사의 지시에 따라 Clearfil SE $bond^{(R)}$(Kuraray Corp., Osaka, Japan)로 치면 처리한 후 Filteck Z $250^{(R)}$(3M/ESPE., St. Paul, USA)을 사용하여 와동을 충전하였다. 적층 충전군의 경우 1.5 mm씩 두 번에 나누어 충전하고 각각 40초씩 중합하였다. $37^{\circ}C$의 증류수에서 24시간 보관 후 교합면쪽 법랑질을 제거하고 수복물의 근원심 폭의 절반되는 지점에서 협설 방향으로 치아를 잘랐다. 주수하에 고속 diamond saw를 사용하여 각 치아의 접착면에 수직으로 1 ${\times}$1 ${\times}$7 mm의 막대 형태의 시편을 만들었으며 만능시험기에 부착하고 1 mm/min의 속도로 미세인장 결합강도를 측정하였다. 2-way ANOVA test와 t-test를 이용하여 95% 유의수준으로 통계 분석한 결과는 다음과 같다. 1. 충전 방법의 경우, 적층 충전군이 단일 충전군보다 높은 평균값을 보였으나 통계적 유의성은 없었다. 2. 와동벽에 따른 결합력 차이의 경우, 치수벽 군이 측벽 군보다 결합력이 큰 것으로 나타났으나 유의성은 없었다. 본 연구 결과만을 토대로 볼 때, 충전 방법과 와동벽의 두 가지 요소가 치질과의 결합력에 미치는 영향이 크지 않았다.

수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구 (MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS)

  • 최상철;박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가 (Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology)

  • 김은지;이규복;진명욱
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.184-193
    • /
    • 2016
  • 목적: 중합 시간이 bulk fill 유동성 복합레진의 미세누출에 미치는 영향을 마이크로시티를 이용하여 평가하고자 하였다. 연구 재료 및 방법: 30개의 발거된 인간 대구치에 변형된 2급 와동인 vertical slot cavity를 형성하였다. SonicFill과 SureFil SDR flow을 단일 충전하였으며, 다른 중합시간(20, 40, 60초)으로 광중합 하였다. 모든 표본은 5000번의 thermal cycle을 시행하였다. 치아는 silver nitrate 용액에 24시간 동안 침전 후 8시간 동안 현상액에 침전하였다. 마이크로시티를 사용하여 시편을 촬영 후 침투된 silver nitrate solution을 3차원적으로 재건하여 그 부피를 측정하였다. 변연 누출 결과값의 통계 처리는 Mann-Whitney test를 사용하였다. 결과: 광중합 시간의 증가는 두 bulk fill 유동성 복합레진에서 변연 누출을 증가시켰다. 두 복합레진 사이 유의한 차이는 없었다. 결론: 중합 시간은 bulk fill 유동성 복합레진의 변연 누출을 증가시킬 수 있는 요인이었다. 또한 마이크로시티를 통해 레진-치아 계면에서 변연 누출의 양을 비파괴적 방법으로 3차원적으로 재건하여 측정할 수 있었다.

Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교 (MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING)

  • 강석호;김오영;오명환;조병훈;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).