• Title/Summary/Keyword: Class Determination

Search Result 182, Processing Time 0.026 seconds

Correlation of Single-Number Ratings for Sound Insulation by Floor Impact (바닥충격음 차단성능 단일수치 평가방법별 상관성에 대한 조사연구)

  • 김흥식;김명준;김하근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.719-723
    • /
    • 2002
  • The purpose of this study is to suggest the correlation of single-number ratings for sound insulation by floor impact. As a assessment method of impact sound insulation. we selected the IIC contour of ISO, A weighted sound level. Inverse A-weighting curve and L-Index of japanese industrial standard. And we estimated the single-number ratings by application the measured data of impact sound level to each method. The results showed that the coefficients of determination between each two single-number ratings were very high (more than 0.9169). And In the condition of same assessment method, the coefficient of determination for light-weight impact sound was higher than that for heavy-weight impact sound.

  • PDF

Laser Induced Fluorimetry IV. Determination of N-Methylcarbamates by 7-Chloro-4-Nitrosobenz-2-Oxa-1,3-Diazole

  • Park, Chan-Seung;Hwang, Kil-Nam;Kim, Ha-Suck;Koh, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.5
    • /
    • pp.411-414
    • /
    • 1989
  • A new sensitive fluorimetric method for the determination of N-methylcarbamates, a class of well known insecticides, based on the derivatization with 7-chloro-4-nitrosobenz-2-oxa-1,3-diazole (NBD-Cl) has been developed. Unreacted NBD-Cl was eluted ahead of derivatized carbamates from C-18 bonded column. An argon ion laser was used as an excitation source of chromatographic eluents and its fluorescence signal was monitored with optical multichannel analyzer. The detection limits of various carbamates were about 100 pg range and the working curves were linear to $10^4-10^5$ nanogram ranges.

A Study on Installation of Washstands in Bathrooms of Elementary School (초등학교 세면시설의 적정 설치에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.460-466
    • /
    • 2011
  • Objectives: Students in elementary schools usually wash their hands in a washstand. However, little attention is paid to the washstand itself. Today, the importance of personal sanitation and hygiene is greatly emphasized. Therefore students' parents and the public are growing increasingly interested in accessibility to washstands by elementary school students in their schools. Methods: With respect to this study, a survey of students and teachers inelementary schools was performed on the installation of washstands in order to determine the proper number of washstands per school. Results: The results show that 1.1 boys (per class) need a washstand, while 1.8 girls (per class) do so in order to maintain a 50% level of crowdedness. By of the regression equation, to maintain 50% congestion (50% of all students feel congestion) there should be 18.5 boys, and the 15.76 girls per washstand. Table 3 is based on the above results, the number of students per washstand (x) and congestion (y), separated by gender according to the results of regression analysis, the correlation of male models in the linear regression analysis and correlation of girls in the regression equation can be obtained. The linear regression fit of less than 0.7 determines that the coefficients of determination are 0.5399 and 0.4195, respectively. Significance was much smaller. Also, according to the simulation using the diffusion model, with 29 students per class more than one washstand should be provided in a school. Girls (per class) need 0.7 more washstands than boys (per class). Conclusions: More washstand facilities for girls than boys are needed. If the target is based on school class size two washstands should be installed. Finally, guidelines and/or standards in the Schools Health Act of Korea forin elementary school washstands is considerably needed.

A report of 42 unrecorded bacterial species isolated from fish intestines and clams in freshwater environments

  • Han, Ji-Hye;Cho, Ja Young;Choi, Ahyoung;Hwang, Seoni;Kim, Eui-Jin
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.3
    • /
    • pp.433-449
    • /
    • 2020
  • Nine fish and one clam species were collected from freshwater environments in Korea, including four lakes, two streams, and the Nakdong River, to investigate the host-associated bacteria. Hundreds of bacterial strains were isolated from the samples using a cell sorter and a dilution plating method. After identification of the bacterial strains using 16S rRNA gene sequences, 42 strains with greater than 98.7% sequence similarity with validly published species were determined to be unrecorded bacterial species in Korea. These strains were phylogenetically diverse and assigned to four phyla, six classes, 17 orders, 27 families, and 32 genera. At the genus level, the unrecorded species were classified as Corynebacterium, Mycobacterium, Mycolicibacterium, Gordonia, Williamsia, Modestobacter, Brachybacterium, Sanquibacter, Arthrobacter, and Mycolicibacterium of the class Actinobacteria; Empedobacter, and Flavobacterium of the class Flavobacteriia; Fictibacillus, Psychrobacillus, Cohnella, Paenibacillus, Rummeliibacillus, Enterococcus, and Vagococcus of the class Bacilli; Aquamicrobium, Paracoccus, and Sphingomonas of the class Alphaproteobacteria; Achromobacter, Delftia, and Deefgea of the class Betaproteobacteria; and Aeromonas, Providencia, Yersinia, Marinomonas, Acinetobacter, and Pseudomonas of the class Gammaproteobacteria. The 42 unrecorded species were subjected to further taxonomic characterization using gram staining, cellular and colony morphological determination, biochemical analyses, and phylogenetic analyses. This paper provides detailed descriptions of the 42 previously unrecorded bacterial species.

A Method of Load Impedance Optimization for High Efficiency Millimeter-wave Range 2nd Harmonic Generation (밀리미터파 대역 제2고조파 고효율 생성을 위한 부하 임피던스의 최적화 방법)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1566-1571
    • /
    • 2011
  • The objective of this paper is to present a quantitative analysis leading to the assessment of optimum terminating impedances in the design of active frequency multipliers. A brief analysis of the basic principal of the GaAs FET frequency multiplier is presented. The analysis is outlined in bias optimization and drive power determination. Utilizing the equivalent circuit model of GaAs FET, we have simulated the optimized load impedance for the maximum output of the active frequency multipliers. The C-class and reverse C-class frequency doublers have been fabricated and the load impedances have been measured. The experimental results are in good agreement with the estimated results in the simulation with the accuracy of 90%.

A Study on the Determination Vibration criteria for High Technology Facilities using FRF - Impact Test- (주파수 응답함수를 이용한 고정밀장비의 진동 허용규제치 결정기법에 관한 연구)

  • 이홍기;박해동;김두훈;김사수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.377-385
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. the former is accurate but requires a great deal of time and efforts while the latter lacks reliability. this paper proposes a new method to solve this problem at a time. the permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Drive by impact Test.

  • PDF

Distortion invariant pattern recognition using Modified synthetic HMT (수정 합성 HMT를 이용한 왜곡불변 패턴 인식)

  • 현영길;김종찬;김정우;도양회;김수중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7B
    • /
    • pp.1361-1369
    • /
    • 1999
  • A hit-miss transform(HMT) using modified synthetic structuring elements(SEs) for distortion-invariant recognition of multiple objects is proposed. A fundamental problem in an HMT is the determination of the optimal SE needed to improve the false alarm rate, and detect distorted objects with various shapes. The proposed synthetic methods of SE provide good solutions against this problem. One is the multistage synthesis of each true class SE using only set theory, and the other is the multistage synthesis of each true class and false class SE using set theory and SDF(synthetic discriminant function) synthesis method. Simulation results show the proposed methods can be used for the recognition of distorted intraclass objects and the discrimination of similar interclass objects.

  • PDF

A study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facility

  • Cho, Seo-Yeon;Kim, Yong-Soo;Park, Da-Won;Park, Chan-Jun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1951-1956
    • /
    • 2019
  • As a part of the preliminary decommissioning plan of KEPCO-NF fuel fabrication facility, DCGLs of three target radionuclides, 234U, 235U, and 238U, were derived using RESRAD-BUILD code and contaminated areas of the facility were classified based on contamination levels from the derived DCGLs. From code simulations, one-room modeling results showed that the grinding room in building #2 was the most restrictive (DCGLgross = 10493.01 Bq/㎡). The DCGLgross results in contaminated areas from one-room modeling were slightly more conservative than three-room modeling. Prior to the code simulation, field survey and measurements conducted by each survey unit. For a conservative approach, the most restrictive DCGLgross in each survey unit was taken as a reference to classify the contaminated areas of the facility. Accordingly, seven rooms and 37 rooms in the nuclear-fuel buildings were classified as Class 1 and Class 2, respectively. As expected, fuel material handling and processing rooms such as the grinding room, sintering room, compressing room, and powder collecting room were included in the Class 1 area.

Characterization of a Low Molecular Weight Heat-Shock Protein cDNA Clone from Nicotiana tabacum

  • Park, Soo-Min;Joe, Myung-Kuk;Hong, Choo-Bong
    • Proceedings of the Botanical Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.18-18
    • /
    • 1999
  • We characterized a cDNA clone for a low molecular weight heat-shock protein (LMW HSP) from tobacco named TLHS-l. Nucleotide sequence determination of TLHS-1 identified an open reading frame for 159 amino acids. To the upstream of the open reading frame, a sequence of 124 nucleotides was determined. To the 3' downstream of the open reading frame, 212 nucleotides were identified which carried poly(A)-tail. Comparison of the open reading frame and hydropathy plot of TLHS-1 with the previously reported class I LMW HSPs showed high identity which classified TLHS-1 as a class I LMW HSP cDNA clone. We proposed that there are six consensus regions in class I LMW HSPs. RNA blot hybridization for TLHS-1 showed a typical expression pattern of heat-shock-inducible gene from three common tobacco cultivars. The open reading frame of TLHS-1 was overexpressed in Escherichia coli. TLHS-1 protein confers thermal protection of other proteins in vitro and in vivo. Thermal induced aggregation of citrate synthase was reduced by purified TLHS-1 protein, and thermal death rate at $50^{\circ}C$ was reduced in E. coli expressing TLHS-l. From these data, we can expect that TLHS-1 acts as a molecular chaperone.perone.

  • PDF

A STUDY HO THE PREDICTION OF DURATION OF ORTHODONTIC TREATMENT IN MALOCCLUSION (부정교합 치료기간의 예측에 관한 연구)

  • Kim, Hyuk-Jae;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.105-112
    • /
    • 1988
  • To predict duration of orthodontic treatment of malocclusion, 304 male and female patients whose orthodontic treatment was finished in department of orthodontics, Infirmary of dental college, Chosun University were studied. The duration of treatment was studied according to types of malocclusion, beginning ages of treatment, Hellman's dental ages, the determination of tooth extraction, types of tooth extraction and types of orthodontic appliance. The following results were obtained. 1. The duration of treatment was 18 months in Class I malocclusion, 20 months in Class II malocclusion and 24 months in Class III malocclusion. 2. The more early treatment was done, the more duration of treatment was needed according to beginning age of treatment and Hellman's dental ages. 3. Treatment of tooth extraction case was needed for 78 days more than that of non-extraction case. 4. The duration of treatment with unilateral extraction of premolars was the shortest (598 days) and that with single arch extraction of premolars was the longest (685 days) according to types of tooth extraction. 5. The duration of treatment by removable appliance was the shortest (237 days) and the combination of removable appliance, headgear and full banded appliance was the longest (1425 days) according to types of orthodontic appliance. 6. The duration of treatment was 18 months in typical orthodontic treatment with 4 extraction of premolar and full banded appliance.

  • PDF