• Title/Summary/Keyword: Civil code

Search Result 1,178, Processing Time 0.027 seconds

Statistical-based evaluation of design codes for circular concrete-filled steel tube columns

  • Li, Na;Lu, Yi-Yan;Li, Shan;Liang, Hong-Jun
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.519-546
    • /
    • 2015
  • This study addresses the load capacity prediction of circular concrete-filled steel tube (CFST) columns under axial compression using current design codes. Design methods given in the Chinese code CECS 28:2012 (2012), American code AISC 360-10 (2010) and EC4 (2004) are presented and described briefly. A wide range of experimental data of 353 CFST columns is used to evaluate the applicability of CECS 28:2012 in calculating the strength of circular CFST columns. AISC 360-10 and EC4 (2004) are also compared with the test results. The comparisons indicate that all three codes give conservative predictions for both short and long CFST columns. The effects of concrete strength, steel strength and diameter-to-thickness ratio on the accuracy of prediction according to CECS 28:2012 are discussed, which indicate a possibility of extending the limitations on the material strengths and diameter-to-thickness ratio to higher values. A revised equation for slenderness reduction factor in CECS 28:2012 is given.

A reliability-based fragility assessment method for seismic pounding between nonlinear buildings

  • Liu, Pei;Zhu, Hai-Xin;Fan, Peng-Peng;Yang, Wei-Guo
    • Structural Engineering and Mechanics
    • /
    • v.77 no.1
    • /
    • pp.19-35
    • /
    • 2021
  • Existing methods to estimate the probability of seismic pounding occurrence of adjacent buildings do not account for nonlinear behavior or only apply to simple lumped mass systems. The present study proposes an efficient method based on subset simulation for fragility and risk assessment of seismic pounding occurrence between nonlinear adjacent buildings neglecting pounding effects with application to finite element models. The proposed method is first applied to adjacent buildings modeled as elastoplastic systems with substantially different dynamic properties for different structural parameters. Seismic pounding fragility and risk of adjacent frame structures with different floor levels is then assessed, paying special attention to modeling the non-linear material behavior in finite element models. Difference in natural periods and impact location are identified to affect the pounding fragility simultaneously. The reliability levels of the minimum code-specified separation distances are also determined. In addition, the incremental dynamic analysis method is extended to assess seismic pounding fragility of the adjacent frame structures, resulting in higher fragility estimates for separation distances larger than the minimum code-specified ones in comparison with the proposed method.

Comparison between the Egyptian and international codes based on seismic response of mid- to high-rise moment resisting framed buildings

  • Ahmed Ibrahim;Ibrahim El-Araby;Ahmed I. Saleh;Mohammed Shaaban
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.347-361
    • /
    • 2023
  • This research aims to assess the behavior of reinforced concrete (RC) residential buildings when moment-resisting frames (MRFs) are used as the lateral resisting system. This investigation was conducted using MIDAS Gen v.19.0. Buildings with various plan footprints (Square, Rectangular, Circular, Triangular, and Plus-Shaped), and different heights (15 m, 30 m, 45 m, and 60 m) are investigated. The defined load cases, the equivalent static lateral load pattern, and the response spectrum function were defined as stated by the American Standard (ASCE 7-16), the 1997 Uniform Building Code (UBC97), the Egyptian Code for Loads (ECP-201), and the European Standard (EC8). Extensive comparisons of the results obtained by the different codes (including the story displacement, the story drift, and the base shear) were undertaken; to assess the response of moment-resisting multi-story framed buildings under lateral loads. The results revealed that, for all study cases under consideration, both ECP-201 and EC8 gave smaller base shear, displacement, and drift by one third to one fourth, around one fourth, around one fifth, respectively for both the ELF and RSA methods if compared to ASCE 7-16 and UBC97.

An Experimental Study on the Reinforcement of Low-Rise RC Structure for Seismic Performance (저층 RC 건물의 내진성능 보강에 관한 실험적 연구)

  • Kim, Dongbaek;Lee, Byeonghoon;Kwon, Soondong;Lee, Induk
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2016
  • Nowaday, most of the low-rise concrete structures which have less than five stories were built before the intensified seismic code was established 2005. According to the fact that our country is not a safety zone ay more, studies are need to reinforce the seismic performance of that structures. The basic frame of low-rise structure are consist of beams and columns with partition walls, therefore that are very weak about secondary wave of earthquake because of the high stiffness. The partition wall are consist of open channel for sunlight or ventilation and intermediate wall. The intermediate walls will enhance the stiffness of columns, but will cause shear failure with short column effects because of the reduced effective depth. But we don't have studies and adequate design code for partition wall effects, therefore some more studies are need for these facts.

Three-dimensional resistivity imaging for site investigations in civil engineering (지반조사를 위한 3차원 전기비저항 탐사)

  • Chung Seung-Hwan;Yi Myeong-Jong;Kim Jung-Ho;Cho Seong-Jun;Song Yoonho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.21-36
    • /
    • 1999
  • Recently resistivity survey is widely used for site investigations in the field of civil engineering. Since such application area requires accurate interpretation tools especially in the area of complicated geology and rough terrain topography, we developed a three-dimensional (3-D) resistivity inversion code, which can reconstruct real earth structures. Furthermore, the inversion code gives resolution-enhanced images by applying the ACB(Active Constraint Balancing) method. With the help of this inversion code, 3-D resistivity survey is now used as new techniques for site investigations in civil engineering problem. By imaging the 3-D resistivity distribution, we could get useful informations such as depth distribution of basement rock, distribution of weak zone, fractures and cavities which is crucial to civil engineers.

  • PDF

Behavior of lightweight aggregate concrete-encased composite columns

  • Al-Shahari, Abbas M.;Hunaiti, Yasser M.;Ghazaleh, Bassam Abu
    • Steel and Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.97-110
    • /
    • 2003
  • An experimental study was conducted to investigate the behavior of eccentric lightweight aggregate concrete-encased composite columns. This study aims at verifying the validity of such type of concrete in composite construction and checking the adequacy of the AISC-LRFD and the British Bridge Code BS 5400 specifications in predicting the column strength. Sixteen full-scale pin ended columns subjected to uniaxial bending about the major axis in symmetrical single curvature were tested.

Seismic pounding effects on adjacent buildings in series with different alignment configurations

  • Abdel Raheem, Shehata E.;Fooly, Mohamed Y.M.;Abdel Shafy, Aly G.A.;Abbas, Yousef A.;Omar, Mohamed;Abdel Latif, Mohamed M.S.;Mahmoud, Sayed
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.289-308
    • /
    • 2018
  • Numerous urban seismic vulnerability studies have recognized pounding as one of the main risks due to the restricted separation distance between neighboring structures. The pounding effects on the adjacent buildings could extend from slight non-structural to serious structural damage that could even head to a total collapse of buildings. Therefore, an assessment of the seismic pounding hazard to the adjacent buildings is superficial in future building code calibrations. Thus, this study targets are to draw useful recommendations and set up guidelines for potential pounding damage evaluation for code calibration through a numerical simulation approach for the evaluation of the pounding risks on adjacent buildings. A numerical simulation is formulated to estimate the seismic pounding effects on the seismic response demands of adjacent buildings for different design parameters that include: number of stories, separation distances; alignment configurations, and then compared with nominal model without pounding. Based on the obtained results, it has been concluded that the severity of the pounding effects depends on the dynamic characteristics of the adjacent buildings and the input excitation characteristics, and whether the building is exposed to one or two-sided impacts. Seismic pounding among adjacent buildings produces greater acceleration and shear force response demands at different story levels compared to the no pounding case response demands.

A Prediction of the Long-Term Deflection of RC Beams Externally Bonded with CFRP and GFRP (CFRP와 GFRP로 외부 부착된 철근콘크리트보의 장기 처짐 예측)

  • Kim, Sung-Hu;Kim, Kwang-Soo;Han, Kyoung-Bong;Song, Seul-Ki;Park, Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.765-772
    • /
    • 2008
  • For RC structures, long-term deformation occurs due to the inherent characteristics, which are creep and shrinkage. In terms of serviceability, it is important to limit deflection caused by the deformation to the allowable deflection. In the recent years, various repair and strengthening methods have been used to improve performance of the existing RC structures. One of the typical methods is FRP externally bonded method (EBR). Fiber reinforced polymer (FRP) has been used worldwide as repair and strengthening materials due to its superior properties. Besides, it has to offer improved strengthening performance not only under instantaneous load but sustained load. Therefore, accurate prediction method of deflection for the RC members externally bonded with FRP under sustained load is required. In this paper, three beams were fabricated. Two beams were externally strengthened with one of CFRP plate and GFRP plate respectively. Total three beams were superimposed under sustained load of 25 kN. During 470 days, deflections at midspan were obtained. Moreover, creep coefficients and shrinkage strains were calculated by using ACI-209 code and CEB-FIP code. In order to predict the deflection of the beams, EMM, AEMM, Branson's method and Mayer's method were used. Through the experiment, it was found that the specimen with CFRP plate has the most flexural capacity and Mayer's method is the most precise method to predict total long-term deflections.

QR Code-Based Strength Labeling Techniques for Concrete Life-Cycle Quality Maintenance (콘크리트 생애주기 품질관리를 위한 QR 코드 기반 강도 라벨링 기술)

  • Kim, Tae-Heon;Kim, Dong-Jin;Park, Seung-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.603-608
    • /
    • 2011
  • In recent years, numerous mega-sized and complex civil infrastructures are being constructed all over the world. Therefore, more precise construction and maintenance technologies are required for these complicated construction projects. Especially, exact strength measurement and curing process monitoring of the concrete structures are very crucial to confirm the safety and effectiveness of these complicated structures. In this paper, a new Quick Response (QR) code-based concrete strength labeling technique using embedded self-sensing monitoring system is introduced. It is important to note that the QR code-based concrete labeling technique enables easy access of the databases related to the concrete strength at anytime, anywhere, and any smart PC devices. Finally, by integrating the proposed QR code-based concrete labeling with the concrete strength databases already prepared at a designated web-server, a feasibility of the current system is investigated for a next generation concrete life-cycle quality maintenance.

A Study for the Evaluation of Ship Collision Forces for the Design of Bridge Pier I : Mean Collision Force (교각에 작용하는 설계선박충돌력 산정에 관한 연구 I : 평균충돌력)

  • Lee, Gye Hee;Hong, Kwan Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.199-206
    • /
    • 2011
  • In Korea, the current design codes for the bridge vessel collision load are based on AASHTO LRFD code which derived from the mean collision forces of the Woisin's test. To estimate the conservativeness of the code, in this study, the mean forces of head on collisions were evaluated from the mass-acceleration relationship of vessel and the deformation-kinetic energy relationship of bow those obtained from the series of nonlinear finite element analysis, and the mean forces were compared to that in AASHTO design code. As results, the variations of the mean forces versus the sizes of vessels were represented similar tendency, even those of the code are very conservative. However, the variations of mean collision force versus those of collision speeds were dominated by the plastic deformation of bow and it was differ from those of the code that have linear relationship with the collision speeds.