• 제목/요약/키워드: Circumferential gaps

검색결과 7건 처리시간 0.016초

센서 전극 사이의 간극을 고려한 최적의 정전용량 센서 (Optimal Cylindrical Capacitive Sensor(CCS) taking into account the Circumferential Gaps between Sensor Electrodes)

  • 안형준;박종민;한동철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.613-618
    • /
    • 2004
  • CCS was developed and applied to rotating machines because of accurately measuring the spindle error motion without significant efforts. However, researches on the CCS have been focused on ideal cases where circumferential gaps were ignored. This paper presents the effects of circumferential gaps and proposes an optimal CCS considering the circumferential gaps. First, electrostatic analysis of the CCS that includes the circumferential gaps is performed using the FEM, and an additional capacitance due to the circumferential gap can be approximated as an equivalent extended sensor length. Second, a mathematical model of the CCS considering the circumferential gaps is derived, and the optimal CCS is determined through minimization of the weighted error amplification factor. Finally, two CCSs, both considering and ignoring the circumferential gaps, are built, and the effectiveness of the optimal design is verified through simulation and experiment.

  • PDF

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제38권sup2호
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.

The evaluation of healing patterns in surgically created circumferential gap defects around dental implants according to implant surface, defect width and defect morphology

  • Im, Se-Ung;Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제38권sup2호
    • /
    • pp.385-394
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the factors affecting healing patterns of surgically created circumferential gap defects around implants in dogs. Materials and Methods: In four mongrel dogs, all mandibular premolars were extracted. After 8 weeks of healing periods, implants were submerged. According to the surface treatment, turned surface was designated as a group A and rough surface as a group B. In each dog, surgical defects on the left side were made with a customized tapered step drill and on the right with a customized paralleled drill. Groups were also divided according to the width of the coronal gaps: 1.0mm, 1.5mm, or 2.0mm. The dogs were sacrificed following 8 weeks and the specimens were analyzed histologically and histomorphometrically. Results: During the postoperative period, healing was uneventful and implants were well-maintained. As the size of the coronal gap was increased, the amount of bone-to-implant contact was decreased. The bone healing was greater in rough surface implants compared to the turned ones. About the defect morphology, tapered shape showed much bone healing and direct bone to implant contact even in the smooth surface implants. Conclusion: Healing of the circumferential defect around dental implant is influenced by the implant surface, defect width and the morphology of the defect. When using rough surface implants, circumferential gap defects within 2 mm do not need any kinds of regenerative procedures and the healing appeared to be faster in the tapered defect morphology than the paralleled one.

Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

  • dos Santos, Pamela Leticia;de Molon, Rafael Scaf;Queiroz, Thallita Pereira;Okamoto, Roberta;de Souza Faloni, Ana Paula;Gulinelli, Jessica Lemos;Luvizuto, Eloa Rodrigues;Garcia, Idelmo Rangel Junior
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.176-196
    • /
    • 2016
  • Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

Fluid-structure coupling of concentric double FGM shells with different lengths

  • Moshkelgosha, Ehsan;Askari, Ehsan;Jeong, Kyeong-Hoon;Shafiee, Ali Akbar
    • Structural Engineering and Mechanics
    • /
    • 제61권2호
    • /
    • pp.231-244
    • /
    • 2017
  • The aim of this study is to develop a semi-analytical method to investigate fluid-structure coupling of concentric double shells with different lengths and elastic behaviours. Co-axial shells constitute a cylindrical circular container and a baffle submerged inside the stored fluid. The container shell is made of functionally graded materials with mechanical properties changing through its thickness continuously. The baffle made of steel is fixed along its top edge and submerged inside fluid such that its lower edge freely moves. The developed approach is verified using a commercial finite element computer code. Although the model is presented for a specific case in the present work, it can be generalized to investigate coupling of shell-plate structures via fluid. It is shown that the coupling between concentric shells occurs only when they vibrate in a same circumferential mode number, n. It is also revealed that the normalized vibration amplitude of the inner shell is about the same as that of the outer shell, for narrower radial gaps. Moreover, the natural frequencies of the fluid-coupled system gradually decrease and converge to the certain values as the gradient index increases.

이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토 (Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly)

  • 이치영
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2017
  • 이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능을 실험적으로 평가하였다. 비틀림 혼합날개 지지격자는 부수로 간 혼합뿐 아니라 부수로 내 혼합을 동시에 증대시킬 수 있도록 설계되었다. 실험을 위한 이중냉각 환형핵연료 모의 집합체로, 봉 중심 간 거리와 봉 외경의 비가 1.08인 봉 간격이 좁은 $4{\times}4$ 정사각 배열의 봉다발을 준비하였다. 실험은 봉다발 유동의 축방향 평균속도가 1.5 m/s, 열유속은 $26kW/m^2$인 조건에서 수행하였다. 원주방향 온도 분포의 경우, 지지격자 상류에서는 부수로 중심 벽면에서, 하류에서는 비틀림 혼합날개 끝이 향하는 벽면에서 온도가 가장 낮게 나타났다. 축방향 온도 분포의 경우, 지지격자 하류 근처에서 온도가 급격하게 감소하는 것으로 측정되었고, 비틀림 혼합날개에 의해 누셀트 수는 최대 56 % 증대되는 것으로 나타났다. 본 실험결과를 토대로 봉 간격이 좁은 이중냉각 환형핵연료 집합체에서 비틀림 혼합날개 지지격자에 의해 강제대류열 전달 성능이 효과적으로 증대될 수 있음을 확인하였다.

THE EFFECTS OF SPURE AND INVENTS ON THE CASTING ACCURACY AND POROSITY OF TI-NI CASTINGS

  • Cho Lee-Ra;Yi Yang-Jin;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.342-350
    • /
    • 2003
  • Statement of problem. Titanium-Nickel alloy might be used in various prosthetic restorations since it has a unique property such as super-elasticity and high fatigue resistance. However, little is known about the casting ability of this alloy. Purpose. This in vitro study compared the casting accuracy and the porosity made with different investments and various sprue designs to ascertain what casting condition would be better for the fabrication of Ti-Ni cast restorations. Material and methods. A total of 70 Ti-Ni alloy crowns were made and divided into 7 groups of 10 copings on a metal master die. For measuring the effect of the sprue numbers, two groups with one and two 8-gauge sprues were compared. Moreover, the results of the conventional sprue and the double thickness sprues were compared. Three investments were used; carbon free phosphate bonded investment, titanium investment and gypsum bonded investment. The cast restorations were evaluated at 48 points on the entire circumferential margin with a stereomicroscope measuring in micrometers. Each crown was radiographically examined for casting defects and porosity. Data on casting accuracy were analyzed using two-way and Post hoc Scheffe's comparison to determine whether significant differences existed at the 95% confidence level. Student-Newman-Keuls test were performed to identify significant differences in the number of voids. Results. The double sprueing group and double thickness group had significantly less marginal discrepancy than the single sprueing group (P<.05 and P<.01, respectively). The castings with phosphate bonded investment showed the least marginal discrepancy and the smoothest surface. The castings invested in the gypsum bonded investment had the greatest gaps in margin and the largest failure rate. The double sprueing group and phosphate bonded investment group had significantly smaller void numbers and smaller void size than the other groups. Conclusion. Within the limitations of this in vitro study, the casting accuracy of the groups using thicker, double sprue design and the phosphate bonded investment was significantly superior. Moreover, void number and size were less than other groups.