• 제목/요약/키워드: Circulation System

검색결과 1,694건 처리시간 0.025초

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

하나로 유동 모의 설비의 유체순환계통 해석 (The Analysis for Flow Circulation System in HANARO Flow Simulation Facility)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.

대출업무 자동화를 위한 시스팀설계에 관한 연구 (System Analysis for the Automated Circulation)

  • 김광영
    • 한국비블리아학회지
    • /
    • 제4권1호
    • /
    • pp.85-102
    • /
    • 1980
  • Accepting the necessity for maintaining the objectives of the existing circulation system, the computer-based system could be designed by the system analyst and librarians to gain a variety of improvements in the maintenance, accessibility of circulation records and more meaningful statistical records. If the terminal can be operated on-line, then this circulation data is transmitted directly to the computer, where it may update to the circulation file immediately or alternatively be kept in direct access file for updating in batch mode. on-line system in the circulation operations is "data-collection system" and "Bar-coded label system" Bar-coded label system is simple, quick, and error-free input of data. Attached to CRT terminal is a "light pen" which is hand held and will read a bar-coded label as the pen is passed over the labels (one affixed to the book itself, other carried on the borrower cards). Instantaneously the data concerning transaction is stored in the central mini-computer. It is useful, economical for us to co-operate many libraries in Korea and design borrower's ID code, book no., classification code in the Bar-coded label system by the members of the computer center and the library staff at every stage. As for book loan, the borrowers ID code, book number and classification code are scanned by the bar-code scanner or light pen and the computer decides whether to loan and store the data. The visual display unit shows the present status of a borrowers borrowing and decides whether borrower can borrow.

  • PDF

집중시스템 모델을 이용한 이중박동 생명보조장치 작동하의 관상순환계 반응해석 (Response Analysis of the Coronary Circulation Under the T-PLS Operation via a Lumped System Model)

  • 고형종;박종천;심은보
    • 한국산업융합학회 논문집
    • /
    • 제12권1호
    • /
    • pp.27-33
    • /
    • 2009
  • In this paper, a computational analysis using a lumped system model is performed to investigate the hemodynamics of coronary circulation under the operation of T-PLS relevant to the cardiac arrest cases. The coronary circulation system is assumed to be comprised of three compartments: coronary arteries, coronary capillaries, and coronary veins. The effect of myocardial muscle contraction or relaxation is represented by temporal variations in the bias pressure. To verify the present method, we analyzed the coronary circulation for normal case and then compared the results with the existing data. Numerical results on the cardiac arrest model showed that T-PLS can increase LAD flow significantly.

  • PDF

청라지구 물순환체계내 주운수로의 흐름유발시설 설치효과 (The Effect of Flow Induction Machine in Water Circulation System of Cheongna Canal Way)

  • 김동언;최계운;박영식;윤근호
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.77-81
    • /
    • 2010
  • This study carried out hydraulic model test for water circulation system in Cheongna district as part of Incheon Free Economic Zone. Canal way project of Cheongna was planned to establish for environment-friendly water circulation system, improve quality of life and diversification of traffic through using boat as a water-friendly international business city. The navigation canal, There are two intake facility in central park and it can purify water 15,000$m^3$ per day. After purify, water move to 8 facility of water culture area which supplies water in canal way. This process called water circulation system in cheongna. Also, there are several flow induction machine in canal way except south-north way. Therefore, this study will verify about validity of water circulation system's safety through hydraulic model test.

  • PDF

극저온 자연순환회로의 가속 및 저중력 구간 유량 분석 (Analysis of the Flow Rate for a Natural Cryogenic Circulation Loop during Acceleration and Low-gravity Section)

  • 백승환;정영석;조기주
    • 한국추진공학회지
    • /
    • 제23권5호
    • /
    • pp.43-52
    • /
    • 2019
  • 극저온 유체를 사용하는 발사체는 극저온 유체의 자연순환회로를 이용하여 발사체의 엔진 입구를 냉각한다. 자연순환회로의 질량유량은 순환시스템을 구성하는 배관의 길이 및 직경과 시스템으로 들어오는 열유입에 의하여 결정된다. 극저온 유체의 자연순환회로의 순환 검증 및 질량유량 측정을 위하여 실험을 진행하였으며, 이론적 계산 결과와 비교하였다. 비교 결과 12%의 오차가 있음을 확인하였다. 이 결과를 바탕으로 발사체 상단에서 저중력 구간 및 가속 구간에서의 자연순환 질량유량을 예측한 내용을 포함한다. 가속구간에서는 산화제탱크가 100 kPa 내외로 유지하는 것이 자연순환유량 증가에 이로웠으며, 저중력구간에서는 중력가속도의 크기에 따른 최적 압력으로 조절해야 자연순환유량의 최고값을 유지할 수 있었다.

대형아트의 상품구성에 따른 동선체계의 특징에 관한 연구 - 공간구조와 공간연출의 특성을 기준으로 - (A Study on the Circulation System on accordance with the Merchandise in Discount Store - with reference to the spatial configuration and the VMD pattern -)

  • 김세은;문정묵
    • 한국실내디자인학회논문집
    • /
    • 제17권6호
    • /
    • pp.137-142
    • /
    • 2008
  • Since mid 1990s, the domestic market in Korea has been changing drastically especially in the field of discount stores. The competition among this market is more severe and the consuming pattern is also changed. This study is to examine the correlation between the customer's circulation and the spatial configuration by using Space Syntax and VMD pattern through the MD plan of each floor in Discount store. Throughout this study, it tries to find out the Quantitative analysis among three factors - the customer's circulation, spatial configuration and VMD investigation. The pattern of customer's circulation appears differently according to the identity of customer and store layout, but with the result, customer's circulation system is in accordance with the floor layout in the store. In result of the study, the circulation of the customer was found to have a close relationship with spatial structure that is composed by the MD pattern in a discount store in the area of food section. Also, the circulation system in the rest area except food section is more affected by the VMD pattern rather than spatial structure.

개방된 2상 자연순환 회로내의 유동특성에 관한 실험적 연구 (An Experimental Study on the Flow Characteristics Inside an Open Two-Phase Natural Circulation Loop)

  • 경익수;이상용
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1313-1320
    • /
    • 1993
  • 본 연구에서는 가시화가 가능한 상승부를 가진 개방된2상 자연순환 회로를 설치하여 각 운전 조건에 따른 순환 유동 특성을 살펴보았다. 즉, 가열량 증가에 따 른 상승부에서의 2상 유동 양식의 변화를 관찰하였고 동시에 가열기 입구 과냉 액체의 순환 유속 및 상승부의 기공률(void fraction)을 측정하였다. 또한 가열기 입구 및 출구에 설치된 밸브의 마찰저항, 가열기 입구 액체의 과냉 정도, 그리고 충전수위등이 전반적인 유동특성에 미치는 영향을 연구하였다.

Post Test Analysis to Natural Circulation Experiment on the BETHSY Facility Using the MARS 1.4 Code

  • Chung, Young-Jong;Kim, Hee-Cheol;Chang, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.638-651
    • /
    • 2001
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic code, MARS 1.4, for the analysis of thermal-hydraulic behavior in PWRs during natural circulation conditions. The code simulates a natural circulation test, BETHSY test 4. la, which was conducted on the integral test facility of BETHSY. The test represented the cooling states of the primary cooling system under single-phase natural circulation, two-phase natural circulation and the reflux condensation mode with conditions corresponding to the residual power, 2% of the rated core power value and 6.8 MPa at the secondary system. Based on MARS 1.4 calculations, the major thermal-hydraulic behaviors during natural circulation are evaluated and the differences between the experimental data and calculated results are identified. The calculated results show generally good behavior with regard to the experimental results; the region of single-phase natural circulation is 100-92% of the initial mass inventory, two-phase natural circulation is 84-63 %, and the reflux condensation mode occurred below 58 %. U-tubes empty and the core uncovery are obtained at 39 % and 34 % of the initial mass inventory, respectively.

  • PDF

온실 난방을 위한 평판형 태양집열기의 열적성능 분석 (Analysis on the Thermal Performance of Flat-plate Solar Collector for Greenhouse Heating(I))

  • 서원명;윤용철;이승환;이석건
    • 한국농공학회지
    • /
    • 제40권6호
    • /
    • pp.46-56
    • /
    • 1998
  • This study was performed to investigate thermal performances of two different types of flat-plate solar collector systems; natural circulation system and forced circulation system. Conclusions obtained from this study are summarized as follows; 1) In the natural circulation system, the total heat amounts retrieved by starting recovery soon after sunrise were ranged from 10.28 to 17.20MJ/m$^2$, while the total heat amounts retrieved by starting recovery after sunset were ranged from 5.31 to 10.77MJ/m$^2$. 2) The collector efficiency in natural circulation system were ranged from 51.1% to 54.1% when the collected heat was retrieved after sunrise and were 65.8~78.0% when the collected heat was retrieved soon after sunset. 3) According to the regression analysis between fluid flow rates and fluid temperature difference at inlet and outlet of collector pipe, there was high regressive corelations with regression coefficient, r, of 0.982. 4) The collector efficiencies estimated for forced circulation system were 73.1~88.6%, and 78.4~94.8%, and 64.2%~74.5%, respectively when fluid circulation rates were 4.2 l/min, and 7.0 l/min, respectively.

  • PDF