• Title/Summary/Keyword: Chromium chloride

Search Result 73, Processing Time 0.024 seconds

Effects of Alloying Elements on Corrosion Resistance of Low Alloyed Steels in a Seawater Ballast Tank Environment (Seawater ballast tank 환경에서 저합금강의 내식성에 미치는 합금원소의 영향)

  • Kim, Dong Woo;Kim, Heesan
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.6
    • /
    • pp.523-532
    • /
    • 2010
  • Co-application of organic coating and cathodic protection has not provided enough durability to low-alloyed steels inseawater ballast tank (SBT) environments. An attempt has made to study the effect of alloy elements (Al, Cr, Cu, Mo, Ni, Si, W) on general and localized corrosion resistance of steels as basic research to develop new low-allowed steels resistive to corrosion in SBT environments. For this study, we measured the corrosion rate by the weigh loss method after periodic immersion in synthetic seawater at $60^{\circ}C$, evaluated the localized corrosion resistance by an immersion test in concentrated chloride solution with the critical pH depending on the alloy element (Fe, Cr, Al, Ni), determined the permeability of chloride ion across the rust layer by measuring the membrane potential, and finally, we analyzed the rust layer by EPMA mapping and compared the result with the E-pH diagram calculated in the study. The immersion test of up to 55 days in the synthetic seawater showed that chromium, aluminium, and nickel are beneficial but the other elements are detrimental to corrosion resistance. Among the beneficial elements, chromium and aluminium effectively decreased the corrosion rate of the steels during the initial immersion, while nickel effectively decreased the corrosion rate in a longer than 30-day immersion. The low corrosion rate of Cr- or Al-alloyed steel in the initial period was due to the formation of $Cr_2FeO_4$ or $Al_2FeO_4$, respectively -the predicted oxide in the E-pH diagram- which is known as a more protective oxide than $Fe_3O_4$. The increased corrosion rate of Cr-alloyed steels with alonger than 30-day exposure was due to low localized corrosion resistance, which is explained bythe effect of the alloying element on a critical pH. In the meantime, the low corrosion rate of Ni-alloyed steel with a longer than 30-day exposure wasdue to an Ni enriched layer containing $Fe_2NiO_4$, the predicted oxide in the E-pH diagram. Finally, the measurement of the membrane potential depending on the alloying element showed that a lower permeability of chloride ion does not always result in higher corrosion resistance in seawater.

3價크롬염에 의한 크롬鍍金

  • Go, Seok-Su;Park, Byeong-Ga
    • Journal of the Korean institute of surface engineering
    • /
    • v.10 no.3
    • /
    • pp.3-11
    • /
    • 1977
  • The trivalent choromium plating process have been studied by serveral group of orkers in the recent years. In the plating process, Alecra 3 process is the most familiar one. Potassium formate and potassium chloride of the bath compositions in the above process, are exchanged for sodium formate and sodium chloride, and then they have been examined characteristics of the electrodeposition using above bath solution and a few optimum conditions. The results are as follows, (1) The characteristics of the electrodeposition ; that is, throwing power, covering power, appearance, and deposition rate are most satisfied when concentration of $CrCl_3{\cdot}6H_2O$ is 0.4 mol/l, and mol ratio of HCOONa to Chromium(III); HCOONa/$Cr^{3+}$, is 2 to 3. (2) Throwing power, covering power, color and deposit rate show a similiar tendency to Alecra 3 process.

  • PDF

Selenium Effect on the Frequency of SCEs Induced by Heavy Metals in Human Lymphocytes (Selenium이 mercury, cadmium 및 chromium에 의한 자매염색분체교환(姉妹染色分體交換)의 빈도(頻度)에 미치는 영향(影響))

  • Koh, Dai-Ha;Ki, No-Suk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.1 s.29
    • /
    • pp.1-10
    • /
    • 1990
  • The protective effect of sodium selenite($Na_2SeO_3$) against the cytogenetic toxicity of heavy metals was investigated on human whole-blood cultures in relation to induction of sister chromatid exchange (SCE) in secondary metaphase chromosome. Methylmercury chloride($CH_3HgCl$), cadmium chloride($CdCl_2$), potassium dichromate($K_2Cr_2O_7$), and sodium selenite caused to the typically dose-dependent increase in sister chromatid exchanges (SCEs) by the concentrations ranging from $0.3{\mu}M\;to\;10{mu}M$. However, the inductions of sister chromatid exchanges by methylmercury chloride or cadmium chloride were inhibited by the simultaneous addition of sodium selenite $1.2{mu}M$. The frequencies of SCE were decreased to the level of control in the molar ratios as 2:1, 1:1, 1:2, and 1:4 of selenium selenite vs. methylmercury chloride, and as 1:1 and 1:2 of selenium selenite vs. cadmium chloride, while the frequencies of SCE induced by potassium dichromate were not changed by the addition of sodium selenite in culture condition. Mitotic indices were decreased in the higher concentrations of chemicals and not significantly changed by the simultaneous addition of sodium selenite to the culture condition containing each chemicals.

  • PDF

Dyeing of Silk Fabrics by Cochineal Extracts (코치닐 추출물에 의한 견섬유 염색)

  • 한명희
    • Textile Coloration and Finishing
    • /
    • v.12 no.2
    • /
    • pp.129-137
    • /
    • 2000
  • Silk fabrics were dyed by Cochineal extracts after mordanted with various mordants and their properties of dyeing, fastness and change of surface color were investigated. Silk fabrics were mordanted with aluminum potassium sulfate, copper acetate, tin chloride, iron sulfate or chromium potassium sulfate at $60^\circ{C}$ for 30 minutes and subsequently dyed at $60^\circ{C}$ for 60 minutes unless mentioned otherwise. The dye-uptake of silk fabrics increased with the concentration of Cochineal extracts and mordants used. Maximum dye-uptake was obtained at pH 3.5-4, regardless of the type of mordants used. Surface color of silk fabrics changed from red purple to purple when mordanted with Al or Cu mordant, from purple to purple blue with Fe mordant and showed red purple with Sn or Cr mordant, respectively. It also changed according to pH of dyeing bath. Dyed silk fabrics showed poor light fastness but good dry-cleaning, perspiration and rubbing fastness.

  • PDF

Development of Metal Complex Dyestuffs with High Fastness and High Adsorption (고견뢰도 및 고흡진율 특성의 금속 착염 염료의 개발)

  • Kim, Woon-Tai;Nam, Won-Woo;Sohn, Byoung-Chung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.115-120
    • /
    • 1995
  • Diazotization of 2-Amino-5-nitrophenol was Synthesized by the direct diazotization method. The diazonium salts are usually stabilized in the from of double salts. The double salts of zinc chloride are the Commonest, and the double salt method is Specially applicable to the yield-up of coupling. The azo dye(2-naphthol-1-(2'-diazo-5'-nitrophenol)) is Converted into a chromium Complex by heating($100^{\circ}C$) with chromic formate, and DMF. The removal of inorganic salts from dyestuffs was performed in DMF solvent. This effect was more pronounced. From these results, It was obtained to liquid dyestuffs of metal complex with High fastness and high adsorption.

Composition and Microstructure of Electroplated Zinc-Chromium Alloy according to Electrolysis Conditions (전해조건에 따른 아연-크롬합금 도금층의 조성 및 조직특성)

  • 안덕수;김대영;예길촌
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.4
    • /
    • pp.232-240
    • /
    • 2002
  • The composition and the microstructure of the Zn-Cr alloys electroplated in chloride bath with EDTA were studied according to electrolysis conditions. The cathode current efficiency decreased with increasing both Cr/(Cr+Zn) ratio and current density. The Cr content of the alloy deposits increased with Cr/(Cr+Zn) ratio and current density The phase structure of Zn-Cr alloy deposits changed from η-Zn through η-Zn+${\gamma}$'-ZnCr to ${\gamma}$'-ZnCr with increasing Cr content of alloys. The surface morphology of Zn-Cr alloy deposits changed from fine needle shaped crystallites through the mixed structure of needle-shaped and granular one to the colony structure with fine granular crystallites according to the change of phase structure

Effect of Chromium Chloride on the Mechanical and Dielectric Properties of EPDM Rubber

  • Salem, M.A.;Khaled, M.A.;Hussein, A.M.;Elway, E.
    • Macromolecular Research
    • /
    • v.11 no.4
    • /
    • pp.256-259
    • /
    • 2003
  • Measurements of Young's modulus, dielectric loss and a.c. conductivity have been carried out on EPDM rubber samples loaded with different concentrations of $CrCl_3$ (0,2,4 and 6 phr). The values of Young's modulus was found to be linearly dependent on the $CrCl_3$ content. Variation of the dielectric loss with temperature showed that $CrCl_3$ may act as plasticizer. However, at higher frequencies the dielectric loss was found to be independent of frequency and the rubber samples may behave as non-polar dielectric. Investigations of the a.c conductivity suggested that the conduction in these rubber samples can be described by small polaron tunneling. In addition, conductivity was found to increase with $CrCl_3$ content.

Effects of Alloyed Carbon on the General Corrosion and the Pitting Corrosion Behavior of FeCrMnN Stainless Steels (FeCrMnN 계 스테인리스강의 일반부식 및 공식부식 거동에 미치는 고용 탄소의 영향)

  • Ha, Heon-Young;Lee, Tae-Ho;Kim, Sung-Joon
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.10
    • /
    • pp.780-789
    • /
    • 2011
  • The effects of alloyed carbon on the pitting corrosion, the general corrosion, and the passivity behavior of Fe18Cr10Mn0.4NxC (x=0~0.38 wt%) alloys were investigated by various electrochemical methods and XPS analysis. The alloyed carbon increased the general corrosion resistance of the FeCrMnN matrix. Carbon enhanced the corrosion potential, reduced the metal dissolution rate, and accelerated the hydrogen evolution reaction rate in various acidic solutions. In addition, carbon promoted the pitting corrosion resistance of the matrix in a chloride solution. The alloyed carbon in the matrix increased the chromium content in the passive film, and thus the passive film became more protective.

CYTOTOXICITY OF DENIAL CAST BASE METAL ALLOYS ON HUMAN ORAL KERATINOCYTES (구강점막 상피세포에 대한 치과 주조용 비귀금속 합금의 세포독성)

  • Choi, Young-Jin;Yook, Jong-In;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.717-729
    • /
    • 1999
  • Although many studies on the cytotoxicity of the dental cast base metal alloys and their components have been carried out, the results are rather conflicting because of the different type of cells used and the various experimental procedures taken. Recently a number of scientists have claimed that it would be preferable to focus on the use of cells from relevant specific location of the human bodies. Consequently, the primary cultured oral keratinocyte derived from oral mucous along with nickel chloride and several of widely used dental cast base metal alloys(two Ni-Cr alloys and one Co-Cr alloy)in domestic were selected for this study, from which 1) The amounts of released metal ions were determined using atomic absorption spectrometry, 2) The cytotoxicity of nickel chloride and dental cast base metal alloys was evaluated via MTT assay, and finally, 3) The amounts of released metal ions and the cytotoxicity of nickel chloride were correlated with the cytotoxicity of dental cast base metal alloys And, the results were summarized as follows; 1. Nickel ion from Ni-Cr alloys and Cobalt ion from Co-Cr alloys resulted in maximum releasing rate during first 2h hours, followed by a decrease in releasing rate with time. Chromium ion were found to be minimal in all alloys. 2. In cytotoxic test. with $40{\mu}M,\;80{\mu}M$ of nickel chloride, there were observed an increase in the relative cell number compared to control samples after 24 hours. With $160{\mu}M$, there was found to be no difference in the relative cell number with control, except that 48 hour showed a increase in relative cell number. With $320{\mu}M$, the relative cell number remained constant and decreased after 48 hours, and with $640{\mu}M$, a continuing decrease in relative cell number was observed throughout test period. 3 The sensitivity of primary cultured oral epithelium to nickel was lower compared to the cells used in other studies. 4. CB-80 Soft and Regalloy showed no cytotoxicity to primary cultured oral epithelium and New crown resulted in a slight cytotoxicity. In conclusion, it was shown that the primary cultured oral keratinocytes could be applied successfully as testing cells in cytotoxicity test. Futhermore, the dental cast base metal alloys used in this study were found to be biocompatible.

  • PDF

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF