• Title/Summary/Keyword: Chloride Ion Diffusion

Search Result 208, Processing Time 0.021 seconds

Study of Thermal Diffusion in the Copper Wire Using SIMS Depth Profiling (이차이온질량분석기의 깊이 분포도를 이용한 동선의 열적 확산에 대한 연구)

  • Park, Jong-Jin;Hong, Tae-Eun;Cho, Young-Jin;Seo, Young-Il;Moon, Byung-Sun;Park, Jong-Chan;Pak, Hyuk-Kyu;Lee, Jeong-Sik
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.43-47
    • /
    • 2008
  • Recently SIMS has attracted interest as new technique to distinguish the primary and the secondary arc beads. A Cs+ primary ion beam was used to detect the $^{12}C^-$, $^{63}Cu^-$, $^{18}O^-$, $^{35}Cl^-$ secondary ions which are formed during depth profiles in the copper wires. In this work, we studied thermal diffusion in the copper wire which are occurred with supplying over-current. The results demonstrated that Carbon and Chloride are diffused in PVC-coated copper wire deeper than none PVC-coated. However Oxygen showed the reverse diffusion property.

Mass Transfer to Amalgamated Copper Rotating Disk Electrode

  • Sulaymon, Abbas H.;Abbar, Ali H.
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.165-171
    • /
    • 2012
  • An experimental study of mass transfer to an amalgamated copper rotating disc electrode has been employed to determine an empirical correlation for the mass transfer rate in laminar flow. The study was performed in a three-electrodes configuration using 0.1 M boric acid and 0.1M potassium chloride as supporting electrolyte with Zn (II) concentration in the range (25-100 mg $dm^{-3}$). Polarization curves at different zinc ion concentration are reported. Hydrogen and oxygen reduction has also been considered.The diffusion coefficients and mass transfer coefficient were obtained using limiting diffusion current technique based on zinc ion reduction. A least squares analysis indicates that the laminar flow results for 13067 < Re > 57552 and 550 < Sc > 1390 can be correlated by the following equation with correlation coefficient (CR) equal to 0.98: $sh=0.61Re^{0.5}Sc^{1/3}$.

An Experimental study on durability improvement of concrete structures by a concrete coating method (도포공법에 의한 콘크리트 구조물의 내구성 증진에 관한 실험적 연구)

  • 조병완;문린곤;박승국;김대민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.721-726
    • /
    • 2003
  • The Durability of Concrete Structure is serverely degraded due to mainly carbonation, sulfate attack and chloride ion diffusion in concrete. The ultimate purpose of this study is to obtain how much the durability of Concrete Structure is improved according to the variation of physical properties in concrete or the frequency of surface coating on concrete. Where, variation of physical properties is a water-cement ratio or amount of air. The experiments are the chliride ion diffusion test, the lapid corrosion test, the lapid carbonation test, the test on resistance to freezing and thawing. Finally, this study shows that the effect by the surface coating method is better than the variation of physical properties in concrete.

  • PDF

Effect of Initial Flexural Crack on Resistance to Chloride Penetration into Reinforced Concrete Members (초기 휨균열이 철근콘크리트 부재의 염화물침투저항성에 미치는 영향)

  • Yang, Eun Ik;Jin, Sang Ho;Kim, Myung Yu;Choi, Yoon Suk;Han, Sang Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.79-87
    • /
    • 2011
  • In this study, the chloride penetration tests were performed for the initially cracked reinforced concrete members. The chloride diffusion characteristics and the critical crack width are compared, and the properties of self-healing are investigated. According to the test results, the chloride penetration resistance was greatly reduced as the surface crack width increased. When the mineral admixtures are added, the chloride penetration resistance of uncracked specimens were effectively increased, however, in case of the blast furnace slag and fly ash, the cracked specimens showed the more reduced resistance than OPC case, inversely. Also, the critical width was $29{\mu}m$, on average, for immersion test. The crack width with $4{\sim}15{\mu}m$ was restored by self-healing, The parts restored by self-healing were seemed to be visually restored, however, the chloride penetration resistance was not restored, perfectly.

A Study on the Quality Deviation of High-Strength Concrete from Multiple Ready Mixed Concrete Companies (다수 레미콘사에서 납품된 콘크리트 품질 편차에 관한 연구)

  • Park, Dong-Cheon;Seok, Won-Kyun;Jeon, Hyun-Soo;Kim, Young-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.577-583
    • /
    • 2022
  • On large-scale sites, concrete is often delivered from a number of ready-mixed concrete companies, but even if the same concrete mixture table is used, it is thought that there will be a difference in quality due to differences in materials and manufacturing equipment. Due to a lack of previous research in this area, this study measured the properties of fresh concrete, compressive strength, and chlorine ion diffusion coefficient using the concrete supplied by 12 ready-mixed companies in Busan. The fresh concrete properties met the criteria. The compressive strength increased by 137% for 30MPa, 131% for 45MPa, and 117% for 80MPa by specified compressive strength. For the chlorine ion diffusion coefficient, the average value for each specified compressive strength could be derived without significant variation. The higher the compressive strength, the greater the deviation , and the lower the compressive strength, the greater the deviation in the chlorine ion diffusion coefficient.

A Study of Time Dependent Diffusion for Prediction Service Life in NPPs Safety Related Concrete Structures (원전 안전관련 콘크리트 구조물의 수명예측을 위한 재령계수에 대한 연구)

  • Lee, Choon-Min;Yoon, Eui-Sik;Kim, Seung-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.136-142
    • /
    • 2019
  • Nuclear power plant concrete structures are in contact with the coast, and durability due to chloride attack is very important because it is used as cooling water by taking seawater. For this purpose, a 3-year long-term saltwater immersion test was carried out to evaluate chloride ion diffusion coefficient and age apponent (m) The m values of the foundation with 4,000 class was 0.35 ~ 0.39, similar to KCI or ACI suggested values. essential service water constructions and tunnels of 5,000 class were 0.44 ~ 0.53 and 6,000 class, and 0.62 of reactor containment buildings were similar to the proposed values of FIB. As a result of the prediction of the service life with the measured age coefficient, all the safety related concrete structures of the nuclear power plants satisfied the service life of more than 60 years.

Durability Performance Evaluations on Resistance to Chloride Attack for Concrete Using LCD Waste Glass Powder (LCD 폐유리 미분말을 사용한 콘크리트의 염해내구성 평가)

  • Kim, Seong-Kyum;Lee, Kwang-Woon;Song, Jae-Ho;Jang, Il-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.289-296
    • /
    • 2018
  • In this study, we evaluated the feasibility and performance of LCD waste glass as a replacement for cement by using LCD waste glass powder which is generated from manufacturing process due to development of LCD industry. Experiments were carried out by replacing 10% and 20% cement of LCD waste glass with particle size of $12{\mu}m$ of LCD waste glass with OPC and particle size of $5{\mu}m$, respectively. Through experiments, basic properties, mechanical properties and durability of concrete were evaluated. Experimental results show that the compressive strength is high at 10% replacement ratio compared to 20%. The lower the particle size, the higher the strength. The durability test evaluated the chloride penetration performance through the chloride ion diffusion coefficient. The higher the substitution rate and the smaller the particle size, the lower the chloride ion diffusion coefficient and the better the OPC than the all substitution rate. As a result, LCD waste glass concrete with low granularity and proper replacement ratio is considered to be advantageous for durability under salt environment.

Improvement of Seawater Corrosion Resistance of Concrete Reinforcing Steel Using by Conductive Photocatalyst (전도성 광촉매를 이용한 콘크리트 철근의 염해 내구성 향상에 관한 연구)

  • Bae, Geun-Guk;Bae, Geun-Woo;Ahn, Yong-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.152-159
    • /
    • 2017
  • In marine environment, the durability of concrete and reinforcing steel is known to be deteriorate by the permeation of chloride ion into concrete. In this study the conductive photocatalyst was used to improve the seawater corrosion resistance of the concrete and steel. Mortar and concrete samples were prepared by mixing with various amounts of conductive active carbon and photocatalytic powder($TiO_2$). The compressive strength of concrete was decreased with the increase of the amount of conductive carbon powders. The samples containing conductive carbon and photocatalytic powders showed the superior seawater corrosion resistance compared with the ordinary sample, which was verified by XRF analysis showing the concentration of chloride ion($Cl^-$) of mortars and concretes. The inhibitive effect of photocatalyst against chloride attack was discussed with the diffusion coefficient of chloride ion into mortar and concrete.

Characteristics of Chloride Ion Behavior in an Cement Matrix Using Calcium Nitrite Inhibitor (아질산칼슘 방청제를 사용한 시멘트 경화체 내의 염소이온 거동 특성)

  • Min-Cheol Shin;Ki-Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.206-213
    • /
    • 2024
  • The present study concerns the inhibition of Calcium Nitrite Inhibitor(Ca(NO2)2) in mortar contaminated by chloride ions. Thus, the corrosion resistance and chloride transport were measured for the mortar containing calcium nitrite inhibitor. As a result, an increase in the dosage of calcium nitrite inhibitor resulted in an increase in the chloride threshold concentration for reinforcement corrosion, while the rate of chloride transport was accelerated. However, the calcium nitrite inhibitor could not guarantee the time to corrosion, due to the increased mobility of chlorides. To ensure the passivity of steel, the dosage of calcium nitrite inhibitor must exceed a certain dosage, ranging from 2.0~3.0 % by cement weight.

A Method on the Rapid Assessment of Resistance to Chloride Ion Penetration for Mortar and Concrete with Mineral Admixtures (혼화재를 사용한 모르타르 및 콘크리트의 염소이온 침투 저항성 평가)

  • Park Jung-Jun;Kim Sung-Wook;Koh Kyung-Taek;Lee Jong-Suk;Lee Jang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.485-492
    • /
    • 2004
  • In this study, ASTM C 1202 which is most commonly used for evaluating the penetration resistance into the concrete is reviewed. The test results by ASTM C 1202 showed that the passed charge could be underestimated as the $OH^-$ ion concentration in the concrete is lowered when the concrete is mixed with the admixtures. Therefore, the modified method using the distilled water was proposed in the paper. According to the test results, the modified method is not susceptible to $OH^-$ ion and temperature rise. In addition, the long term emersion test for the concrete mixed with the admixtures in the NaCl solution showed that the chloride diffusion coefficient tested by the modified method have higher correlation compared to the conventional ASTM method.