• Title/Summary/Keyword: Chip flow

Search Result 315, Processing Time 0.028 seconds

VLSI Design for Motion Estimation Based on Bit-plane Matching (비트 플레인 정합에 의한 움직임 추정기의 VLSI 설계)

  • Go, Yeong-Gi;O, Hyeong-Cheol;Go, Seong-Je
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.5
    • /
    • pp.509-517
    • /
    • 2001
  • Full-search algorithm requires large amount of computation which causes time delay or very complex hardware architecture for real time implementation. In this paper, we propose a fast motion estimator based on bit-plane matching, which reduce the computational complexity and the hardware cost. In the proposed motion estimator, the conventional motion estimation algorithms are applied to the binary images directly extracted from the video sequence. Furthermore, in the proposed VLSI motion estimator, we employ a Pair of processing cores that calculate the motion vector continuously By controlling the data flow in a systolic fashion using the internal shift registers in the processing cores, we avoid using SRAM (local memory) so that we remove the time overhead for accessing the local memory and adopt lower-cost fabrication technology. We modeled and tested the proposed motion estimator in VHDL, and then synthesized the whole system which has been integrated in a 0.6-$\mu$m triple-metal CMOS chip of size 8.15 X 10.84$\textrm{mm}^2$.

  • PDF

Development of Microprocessor-based Automatic Storage Controller and Temperature Auto-measurement System for Horticultural Crops (마이크로프로쎄서를 이용한 과채류 자동 저장 제어장치의 제작과 온도 자동계측 관리 시스템)

  • Park, Je-Kyun;Chun, Jae-Kun;Lee, Seung-Koo;Kim, Kong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.845-849
    • /
    • 1988
  • A laboratory scale storage facility consisting of a cold room, sample jars and a ventilation device was designed and built. Storaging sample jars (1.7 l) for fruit were fabricated with transparent acryl and provided with a constant air flow. For the supplying of air to sample jars, the air distributing system was built with solenoid valves, an air precooling coil and a pressure equalizing tank. To provide the programmable storaging environment of the facility a microprocessor-based controller was designed and installed. The controller was built with the 8 bit microprocessor (Z-80), EPROM, RAM, programmable peripheral interface(8255 PPI), and A/D converter. Softwares for the auto-temperature measurement and control of the storage system were developed and systemized in ROM. The automated storage system was applied to citrus storage, and the temperature of the storage facilities was successfully acquisited to the computer and controlled.

  • PDF

Machinability Evaluation according to Variation of Endmill Shape for High Speed Machining (고속가공용 엔드밀 형상변화에 따른 가공성 평가)

  • Kang, Myung-Chang;Kim, Jeong-Suk;Lee, Deuk-Woo;Kim, Kwang-Ho;Ha, Dong-Geun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.133-138
    • /
    • 2002
  • The technique of high speed machining is widely studied in machining fields, because the high efficiency and accuracy in machining can be obtained in high speed machining. Unfortunately the development of tool fur high speed machining in not close behind that of machine tool. In this study, 10 types flat endmill is prepared for obtaining data according to tool shape. Especially, we concentrated in helix angle, number of cutting edge and rake angle. Cutting condition is selected for several experiments and measuring cutting farce, tool life, tool wear and chip shape according to cutting length. 3-axis cutting farces are acquired from the tool dynamometer with high natural frequency, as the conventional tool dynamometer (9257B, Kistler) has cannot measure the state of high frequency force. Particularly, we found out that the axial cutting force waveform has a good relation with tool wear features. And flow is interrupted at the beginning of cutting by the decrease of rake angle. By above results. it is suggested the endmill tool with 45$^{\circ}$helix angle, 6 cutting edge and -15$^{\circ}$rake angle is suitable for high speed machining.

Design of General Peripheral Interface Using Serial Link (직렬 링크 방식의 주변 장치 통합 인터페이스 설계)

  • Kim, Do-Seok;Chung, Hoon-Ju;Lee, Yong-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.1
    • /
    • pp.68-75
    • /
    • 2011
  • The performance of peripheral devices is improving rapidly to meet the needs of users for multimedia data. Therefore, the peripheral interface with wide bandwidth and high transmission rate becomes necessary to handle large amounts of data in real time for multiple high-performance devices. PCI Express is a fast serial interface with the use of packets that are compatible with previous PCI and PCI-X. In this paper, we design and verify general peripheral interface using serial link. It includes two kinds of traffic class (TC) labels which are mapped to virtual channels (VC). The design adopts TC/VC mapping and the scheme of arbitration by priority. The design uses a packet which can be transmitted through up to four transmission lanes. The design of general peripheral interface is described in Verilog HDL and verified using ModelSim. For FPGA verification, Xilinx ISE and SPARTAN XC3S400 are used.We used Synopsys Design Compiler as a synthesis tool and the used library was MagnaChip 0.35um technology.

Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode (Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템)

  • Yi In-Je;Kang Chi-Jung;Kim Yong-Sang;Kim Ju-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

Prevalence and Genotype Distribution of Human Papillomavirus among Women from Henan, China

  • Wang, Xiao-Chuan;Sun, Liang-Qi;Ma, Li;Li, Hua-Xin;Wang, Xiu-Li;Wang, Xin;Yun, Tian;Meng, Nian-Long;Lv, Da-Le
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7333-7336
    • /
    • 2014
  • Human papillomavirus (HPV) infection has been implicated as a causative of cervical cancer. In the present study, a total of 578 samples from females attending the gynecological outpatient clinic in Henan province, China, were collected and the HPV genotypes were detected by gene chip and flow-through hybridization. Overall, 44.5% (257/578) females were found to be HPV DNA positive, and the high risk HPV (HR-HPV) rate was 35.1% (203/578). The first peak of HR-HPV infection appeared in the >60 year-old group (55.0%), and the second was within the 51-55 year-old group (50.0%) (${\chi}^2$=19.497, p<0.05). HPV 16 was the most prevalent genotype (9.2%), followed by HPV 52 (7.8%), HPV 6 (6.9%), HPV 11 (5.9%) and HPV 42 (5.0%). The single type HPV infection was 30.4%, with the five majority prevalent genotype HPV 16 (16.5%), HPV 52 (14.3%), HPV 6 (12.6%), HPV 42 (8.6%), HPV 31 (5.1%). The multiple-type HPV infections were 14.0%, and HPV 16 was the most prevalent type (29.6%), followed by HPV 52 (24.7%), HPV 6 (22.2%), HPV 11 (22.2%), HPV 42 (17.3%) and HPV 39 (17.3%).

The Effest of Matrix of Nodular Graphite Cast Iron on Machinability in Lathe Turning - Cutting Force, Cutting Ratio and Shear Angle- (球狀黑鉛鑄鐵의 其他組織이 切削性에 미치는 영향 I)

  • 성환태;안상욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.807-813
    • /
    • 1986
  • The orthogonal cutting method of the nodular graphite cast iron in the lathe turning, whose matrix were formulated under two kinds of annealing conditions, has been experimentally studied and the results investigated. The various characteristics of machinabilities of the nodular cast iron, depending upon its matrix, have been obtained from the results as follows. (1) As depth of cut increases, the cutting ratio and the shear angles tend to slightly increase, and as the containing quantity of ferrite matrix increases, they slightly decrease. (2) As depth of cut increases, the cutting force increases in an approximate straight line, and as the containing quantity of ferrite matrix increases, they decreases and the decreasing rate is about 20-30%. (3) As the containing quantity of ferrite matrix increases, the friction force acting on the tool face decreases and the decreasing rate is about 34-40% in case of the lower depth of cut, but in case of the higher depth of cut the decreasing rate is very small. (4) Both shearing force and vertical force show a lineal increases, and according as ferrite matrix increases there is a decrease by 25% in shearing force and a 12-25% decrease in vertical force. (5) Shearing speed and chip flow speed keep almost a constant value irrespective of matrix.

A Study on the Implementation and Performance Analysis of 900 MHz RFID System with Convolution Coding (콘벌루션 부호를 적용한 900MHz 대역 RFID 시스템 구현 및 성능 분석에 관한 연구)

  • Yun Sung-Ki;Kang Byeong-Gwon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In recent years, RFID has received much attention because of spread usage in industrial applications including factory, material flow, logistics and defense areas. However, there is only CRC-16 for error detection in ISO/IEC 18000-6 Protocols prepared for 860-960 MHz RFID, high error rates are expected in cases of high level of security and noisy envirionment. In this paper, we propose a usage of convolution code as a method for satisfying the high level of security requirement and system error performance.'1'he signal control function is implemented in a microprocessor with RF modulation and the convolutional encoding and Viterbi decoding are implemented in an FPGA chip.'The frame error rates are measured with and without convolution coding under the channel conditions of line-of- sight and non line-of-sight, respectively.

  • PDF

Investigation of Chemotactic Activities in Differentiated HL-60 Cells by a Time-lapse Videomicroscopic Assay

  • Jung, Yun-Jae;Woo, So-Youn;Ryu, Kyung-Ha;Jang, Myoung-Ho;Miyasaka, Masayuki;Seoh, Ju-Young
    • IMMUNE NETWORK
    • /
    • v.6 no.2
    • /
    • pp.76-85
    • /
    • 2006
  • Background: Chemotaxis is one of the cardinal functions of leukocytes, which enables them to be recruited efficiently to the right place at the right time. Analyzing chemotactic activities is important not only for the study on leukocyte migration but also for many other applications including development of new drugs interfering with the chemotactic process. However, there are many technical limitations in the conventional in vitro chemotaxis assays. Here we applied a new optical assay to investigate chemotactic activities induced in differentiated HL-60 cells. Methods: HL-60 cells were stimulated with 0.8% dimethylformamide (DMF) for 4 days. The cells were analyzed for morphology, flow cytometry as well as chemotactic activities by a time-lapse videomicroscopic assay using a chemotactic microchamber bearing a fibronectin-coated cover slip and an etched silicon chip. Results: Videomicroscopic observation of the real cellular motions in a stable concentration gradient of chemokines demonstrated that HL-60 cells showed chemotaxis to inflammatory chemokines (CCL3, CCL5 and CXCL8) and also a homeostatic chemokine (CXCL12) after DFM-induced differentiation to granulocytic cells. The cells moved randomly at a speed of $6.99{\pm}1.24{\mu}m/min$ (n=100) in the absence of chemokine. Chemokine stimulation induced directional migration of differentiated HL-60 cells, while they still wandered very much and significantly increased the moving speeds. Conclusion: The locomotive patterns of DMF-stimulated HL-60 cells can be analyzed in detail throughout the course of chemotaxis by the use of a time-lapse videomicroscopic assay. DMF-stimulated HL-60 cells may provide a convenient in vitro model for chemotactic studies of neutrophils.

Reactive Ion Etching and Magnetically Enhanced Reactive Ion Etching Process of Low-K Methylsilsequioxane Insulator Film using $CF_4$ and $O_2$ ($CF_4$$O_2$를 이용한 저유전율 물질인 Methylsilsequioxane의 RIE와 MERIE 공정)

  • Jung, Do-Hyun;Lee, Yong-Soo;Lee, Kil-Hun;Kim, Kwang-Hun;Lee, Hee-Woo;Choi, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1491-1493
    • /
    • 2000
  • Continuing improvement of microprocessor performance involves in the device size. This allow greater device speed, an increase in device packing density, and an increase in the number of functions that can reside on a single chip. However this has led to propagation delay, crosstalk noise, and power dissipation due to resistance-capacitance(RC) coupling become significant due to increased wiring capacitance, especially interline capacitance between the metal lines on the same metal level. So, MSSQ which has the permittivity between 2.5-3.2 is used to prevent from these problems. For pattering MSSQ(Methylsilsequioxane), we use RIE(Reactive Ion Etching) and MERIE(Magnetically enhanced Reactive Ion Etching) which could provide good anisotropic etching. In this study, we optimized the flow rate of $CF_{4}/O_2$ gas, RF power to obtain the best etching rate and roughness and also analyzed the etching result using $\alpha$-step profilemeter, SEM, infrared spectrum and AFM.

  • PDF