• Title/Summary/Keyword: Chest PA projection

Search Result 15, Processing Time 0.022 seconds

The Relationship of Radiation Dose and Image Quality According to the Condition of Chest PA

  • Son, Jin-Hyun;Min, Jung-Whan;Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.165-169
    • /
    • 2011
  • The purpose of this study is to compare the measurement result of radiation dose by using standard thoracic phantom and ionization chamber to advice proposal in the shooting condition of chest PA projection at hospitals recently. And to understand the change between radiation dose and resolution in different conditions. The period this study was from August 2010 to September 2010 and the subjects of the study was 3 general hospitals, 4 personal hospitals and 1 laboratory at the college. Finally we study with 6 DR, 1 CR, and 4 F/S equipments. Most hospitals met advice proposal, but some of the hospitals exceed advice dose from the result of our study. We can lower radiation dose about 25% when kVp is lowered about 20% in DR equipment. And we can lower radiation dose about 50% when mAs is lowered about 35%. The image quality was similar to the original in the study. Most hospitals which exceed advice dose were personal hospitals. The reason why it happened is that radiation dose for chest PA projection at personal hospitals is higher than general hospitals and the personal hospitals' equipments are older than general hospitals' equipments. We guess that patients' radiation dose of chest PA projection can be lowered from the result.

  • PDF

A Study on the Prevention of Healthcare Associated Infection in Chest PA Projection of Contact Infected Patients (접촉성 감염환자 흉부검사 시 의료관련감염 예방에 대한 연구)

  • Lee, Sang-Won;Kim, Dong-Jin;Lee, Bae-Won
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.297-304
    • /
    • 2018
  • This study proposes measures and methods to reduce healthcare associated infections by comparing and analyzing the bacterial contamination level before and after putting on personal protective equipment (PPE) on the test equipment and the contact infected patients getting chest PA projections. Among the 50 inpatients who were diagnosed with C. difficile, MRSA, and VRE, 28 patients who were instructed to undergo chest PA projection and follow-up were chosen, The 3 parts that come in contact with the detector, chin, chest, and hands, were designated for all, and the bacterial contamination level before and after disinfection and before and after putting PPE was determined. Statistical analysis was performed using Medcalc version 14, and quantitative analysis was performed using paired student t-test, with statistical significance being noted at p<0.05. Results for the comparison of the mean values before and after disinfection of the detector, chin (3.000), chest (2.000), and hands (3.430), showed that the number of bacteria after disinfection was lower than it was before disinfection. Analyzing for each part before and after disinfection, there were statistically significant differences for the chin, chest, and hands (p<0.01). Results for the comparison of the mean values before and after putting on PPE, chin (2.202), chest (2.140), and hands (4.213), showed that the number of bacteria after putting on PPE was lower than it was before putting on PPE. Analyzing for each part before and after putting on PPE, there were statistically significant differences for the chin, chest, and hands (p<0.03). As a result, it was confirmed that the number of bacteria after putting on PPE was lower than it was before putting it on. In the future, expanding the research scope for contact infected patients will establish standards for quarantine guidelines depending on the way it spreads, and contribute to the prevention of healthcare associated infections.

Utility Comparison of Chest Lateral Decubitus Projection with AP and PA Position (흉부 측와위 촬영 시 전후방향과 후전방향 검사의 유용성 비교)

  • Choi, Guirack
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.233-238
    • /
    • 2013
  • Chest lateral decubitus radiation exposure PA be carried out in general, but emergency patient or the patient's discomfort in the body examination had a lot of inconvenience. In this study, we compared AP and PA image quality, patient safety, and analysis of the examination effectiveness between the two tests was to evaluate the usefulness. Pleurisy or pneumothorax in patients with suspected or diagnosed chest lateral decubitus radiation exposure 30 consecutive patients (male 20 patients, 10 females) were included in the study. Image quality evaluation method microstructure of lung, wide areas of diagnosis, a clear air-fluid interface, the patient rotate, cardiac shadow and sharp diaphragmatic was based on Department of Radiology specialist, division of pulmonology resident blind test was evaluated by four people. Chest decubitus by radiation exposure the AP and PA position examination the usefulness of comparative analysis Image quality in the AP and PA, whereas there was no significant difference in attitude, Stability of the patient and Radiation's examination efficiency AP position compared to the position of PA scores were higher. PA position does not require a examination may be of AP position in a position to suggest that.

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

Consideration of Patient Position on Posteroanterior Chest Projection (흉부 후·전 검사 시 검사자세에 관한 고찰)

  • Joo, young-cheol;Lim, cheong-hwan;Lim, woo-taek;Kim, hee-jin;Lee, seung-hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.161-162
    • /
    • 2015
  • 본 연구는 chest PA 검사 시 교과서에서 권고하는 검사자세와 임상에서 주로 이용되고 있는 검사자세의 폐야와 견갑골의 겹침 정도 차이를 비교 고찰함으로써, 임상에서 사용되고 있는 자세의 유용성을 알아보고자 진행한 연구이다. 연구 결과 세 자세 모두 견갑골을 폐야에서 제거하는데 유사한 결과를 보였으며, 연령에 따른 겹침의 차이는 통계적 유의성이 없었으나, 임상에서 현재 임상에서 사용 중인 검사자세가 성별에 따른 겹침 면적에는 차이를 보였으며, 통계적으로도 유용한 결과는 보였다.

  • PDF

A Study of Magnification of Cardiac Size and Cardiothoracic Ratio on Chest Posteroanterior Projection in Digital Radiography System (디지털방사선 환경에서 흉부 후.전방향 검사 시 심장과 심흉비 확대에 관한 연구)

  • Joo, Young-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.195-196
    • /
    • 2014
  • 현재 디지털방사선 환경으로 변화하고 있는 추세에 과거 필름-스크린 방식에서 사용되던 흉부 후 전 방향 검사 시 초점 영상 수신부 간의 거리가 디지털방식의 장비에도 여전히 적용되고 있다. 이에 본 연구에서는 3개의 DR장비에서 각 영상수용체의 제조특성을 고려하였을 때 실제 심장 및 심흉비의 확대정도에 대해 알아보고, 임상에서 DR 장비를 이용한 Chest PA 검사 시 심장 및 심흉비의 확대도에 대한 정보를 제공하고자 한다.

  • PDF

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

An Accuracy Evaluation on Convolutional Neural Network Assessment of Orientation Reversal of Chest X-ray Image (흉부 방사선영상의 좌, 우 반전 발생 여부 컨벌루션 신경망 기반 정확도 평가)

  • Lee, Hyun-Woo;Oh, Joo-Young;Lee, Joo-Young;Lee, Tae-Soo;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.65-70
    • /
    • 2020
  • PA(postero-anterior) and AP(antero-posterior) chest projections are the most sought-after types of all kinds of projections. But if a radiological technologist puts wrong information about the position in the computer, the orientation of left and right side of an image would be reversed. In order to solve this problem, we utilized CNN(convolutional neural network) which has recently utilized a lot for studies of medical imaging technology and rule-based system. 70% of 111,622 chest images were used for training, 20% of them were used for testing and 10% of them were used for validation set in the CNN experiment. The same amount of images which were used for testing in the CNN experiment were used in rule-based system. Python 3.7 version and Tensorflow r1.14 were utilized for data environment. As a result, rule-based system had 66% accuracy on evaluating whether the orientation reversal on chest x-ray image. But the CNN had 97.9% accuracy on that. Being overcome limitations by CNN which had been shown on rule-based system and shown the high accuracy can be considered as a meaningful result. If some problems which can occur for tasks of the radiological technologist can be separated by utilizing CNN, It can contribute a lot to optimize workflow.

Leision Detection in Chest X-ray Images based on Coreset of Patch Feature (패치 특징 코어세트 기반의 흉부 X-Ray 영상에서의 병변 유무 감지)

  • Kim, Hyun-bin;Chun, Jun-Chul
    • Journal of Internet Computing and Services
    • /
    • v.23 no.3
    • /
    • pp.35-45
    • /
    • 2022
  • Even in recent years, treatment of first-aid patients is still often delayed due to a shortage of medical resources in marginalized areas. Research on automating the analysis of medical data to solve the problems of inaccessibility for medical services and shortage of medical personnel is ongoing. Computer vision-based medical inspection automation requires a lot of cost in data collection and labeling for training purposes. These problems stand out in the works of classifying lesion that are rare, or pathological features and pathogenesis that are difficult to clearly define visually. Anomaly detection is attracting as a method that can significantly reduce the cost of data collection by adopting an unsupervised learning strategy. In this paper, we propose methods for detecting abnormal images on chest X-RAY images as follows based on existing anomaly detection techniques. (1) Normalize the brightness range of medical images resampled as optimal resolution. (2) Some feature vectors with high representative power are selected in set of patch features extracted as intermediate-level from lesion-free images. (3) Measure the difference from the feature vectors of lesion-free data selected based on the nearest neighbor search algorithm. The proposed system can simultaneously perform anomaly classification and localization for each image. In this paper, the anomaly detection performance of the proposed system for chest X-RAY images of PA projection is measured and presented by detailed conditions. We demonstrate effect of anomaly detection for medical images by showing 0.705 classification AUROC for random subset extracted from the PadChest dataset. The proposed system can be usefully used to improve the clinical diagnosis workflow of medical institutions, and can effectively support early diagnosis in medically poor area.