• Title/Summary/Keyword: Chemical detection methods

Search Result 245, Processing Time 0.026 seconds

Pulsed Amperometric Detection of Metal Ions Complexing with EDTA in a Flow Injection System

  • 이준우;여인형;편종홍
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.3
    • /
    • pp.316-318
    • /
    • 1997
  • A general and universal detection method, which can be used in high performance liquid chromatography (HPLC) and flow injection analysis (FIA) system for the determination of any metal ions complexing with ethylenediaminetetraacetic acid (EDTA), is demonstrated. Pulsed amperometric detection scheme is applied in a flow-through thin layer electrochemical cell at an Au working electrode. Fluctuation of peak current level at the same flow rate of carrier solution is minimized at this solid working electrode, whereas not at a dropping mercury electrode. Removal of dissolved oxygen can be omitted with this detection method, which is a required step for cathodic detection methods. Also, a group of metal ions can be determined selectively and indirectly with this detection scheme.

Rapid Detection Methods for Biogenic Amines in Foods (식품 내 바이오제닉아민 신속검출기술 개발 동향)

  • Lee, Jae-Ick;Kim, Young-Wan
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.141-147
    • /
    • 2012
  • Biogenic amines have been used as chemical indicators to estimate bacterial spoilage of foods, particularly fish and fish products, cheese, and fermented foods. So far many chromatography methods have been developed to detect biogenic amines in foods. Although these instrumental analyses exhibit good sensitivity, they cannot be used as rapid detection methods due to the chemical treatment of the samples and the time-consuming process involved. For the rapid and simple detection of biogenic amines, enzyme linked immunosorbent assay kits are commercially available. In addition, analytical systems with enzyme-based amperometric biosensor detection have been increasingly developed. The biosensors used to detect the biogenic amines are based on the action of either amine oxidases or amine dehydrogenases that catalyzes the oxidative deamination of biogenic amines to the corresponding aldehydes and ammonia. This review mainly focused on the principle, development, and applications of the detection methods for rapid detection of biogenic amines in foods.

Flow Injective Determination of Thiourea by Amperometry

  • Lee Joon-Woo;Mho Sun-Il;Pyun Chong Hong;Yeo In-Hyeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1038-1042
    • /
    • 1994
  • The amperometric responses of thiourea were studied in 0.1 M NaOH by flow injection analysis. D. C. amperometric and pulsed amperometric detection methods were applied for the determination of thiourea at novel metal electrodes such as Pt and Au. Triple-step potential waveforms were adopted in the pulsed amperometric detection. With an optimized pulsed waveform, the current for the oxidation of thiourea was examined with the variation of flow rate of carrier solution and with the change in the amount of sample injected. Gold working electrode turned out to be better in sensitivity and signal to noise ratio than Pt electrode in the pulsed amperometric detection of thiourea. Detection limit is estimated to be 5.33 ${\times}$ 10$^{-5}$ M with this detection method.

The Coordination of Pyridyl-N to Pentacyanoferrate for the Electrochemical Detecting Small Organic Molecules

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.595-599
    • /
    • 2013
  • The coordination of pyridyl-N to pentacyanoferrate for the detection of small organic antigens in solution is presented. The unique contribution of this paper is the direct conjugation of pyridyl-N in small organic antigens to pentacyanoferrate. Pentacyanoferrate is promising as an electrochemical label owing to its good electro-chemical properties, which can be utilized to generate an electrical signal in homogeneous electrochemical immunoassays. The facilely synthesized pyridyl-N to pentacyanoferrate was characterized by the electrochemical and spectroscopic methods. Hippuric acid (HA) has been detected competitively on the interaction of free HA and pentacyanoferrate-(4-aminomethylpyridine-hippuric acid) (Fe-HA) to its antibody, with the detection limit of 0.50 ${\mu}g\;mL^{-1}$. While pentacyanoferrate-based immunoassay is in its simplicity and infancy, the proposed immunoassay offers attractive opportunities for developing pyridyl-N-based the electrochemical detection of small organic antigens in the health care area.

Chemiluminogenic imaging for highly sensitive detection of DNA

  • Kai, Masaaki;Hirayama, Fumiko;Ohta, Kazuko;Kabashima, Tsutomu;Lee, Myung-Koo
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.407.2-407.2
    • /
    • 2002
  • We have been studing sensitive non-enzymatic chemiluminescence (CL) imaging methods for the detection of DNA. For one of our methods, a unique chemical derivatization reagent. 3'. 4', 5'-trimethoxyphenylglyoxal (TMPG) was utilized. This reagent reacted specifically with guanine bases in nucleic acids to quickly produce a chemiluminescent derivative under mild reaction conditions. (omitted)

  • PDF

Diagnostic accuracy of digital images for detection of artificial chemical proximal caries (화학적 인공 인접면 치아우식증의 디지털 영상 진단능 평가)

  • Park Geum-Mee;Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.91-95
    • /
    • 2003
  • Purpose : To compare the diagnostic accuracy of proximal caries detection between Kodak Insight film and the Biomedisys CDX2000HQ digital (CCD) sensor. Materials and Methods: 156 proximal surfaces of extracted teeth, 78 of which had chemical artificial caries, were used in this study. Four observers interpreted the radiographs using a five-point confidence rating scale to record their diagnoses. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa values. Result: Analysis using receiver operating characteristic curves revealed the areas under each curve which indicated a diagnostic accuracy of 0.951 in Insight and 0.952 in CDX2000HQ digital sensor. ANOVA revealed no significant differences between the two images with respect to caries detection. Kappa values indicated that the mean intra-observer agreement was 0.85 and inter-observer agreement 0.71 in conventional radiography. In digital radiography, the mean intra-observer agreement was 0.84 and inter-observer agreement 0.72. Conclusion: The results suggest that no significant difference exists between the two modalities for artificial caries detection and that CDX2000HQ was as good as Insight film for this purpose.

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Base/Neutral Priority Pollutants in Soil (토양 중의 비휘발성 염기/중성 유기 Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seok Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.6
    • /
    • pp.418-426
    • /
    • 1994
  • This study was aimed at the detection of 40 semi-volatile organic base/neutral compounds from soil among 129 priority pollutants listed by EPA. Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as a extraction and concentration method for priority pollutants in soil. Extracts were analyted by GC/MS-SIM(selected ion monitoring). The analytical methods were tested by standard compounds spiked into blank soil. Accuracy and precision of the methods were measured by calculation of mean recovery and mean relative standard deviation. And the method detection limits were estimated.

  • PDF

Graphene and Carbon Quantum Dots-based Biosensors for Use with Biomaterials

  • Lee, Cheolho;Hong, Sungyeap
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.1
    • /
    • pp.49-59
    • /
    • 2019
  • Biosensors, which are analysis devices used to convert biological reactions into electric signals, are made up of a receptor component and a signal transduction part. Graphene quantum dots (GQDs) and carbon quantum dots (CQDs) are new types of carbon nanoparticles that have drawn a significant amount of attention in nanoparticle research. The unique features exhibited by GQDs and CQDs are their excellent fluorescence, biocompatibility, and low cytotoxicity. As a result of these features, carbon nanomaterials have been extensively studied in bioengineering, including biosensing and bioimaging. It is extremely important to find biomaterials that participate in biological processes. Biomaterials have been studied in the development of fluorescence-based detection methods. This review provides an overview of recent advances and new trends in the area of biosensors based on GQDs and CQDs as biosensor platforms for the detection of biomaterials using fluorescence. The sensing methods are classified based on the types of biomaterials, including nucleic acids, vitamins, amino acids, and glucose.

Effect of Nanostructures of Au Electrodes on the Electrochemical Detection of As

  • Kastro, Kanido Camerun;Seo, Min Ji;Jeong, Hwakyeung;Kim, Jongwon
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.206-213
    • /
    • 2019
  • The development of simple methods for As detection has received great attention because As is a toxic chemical element causing environmental and health-related issues. In this work, the effect of nanostructures of Au electrodes on their electroanalytical performance during As detection was investigated. Different Au nanostructures with various surface morphologies such as nanoplate Au, nanospike Au, and dendritic Au structures were prepared, and their electrochemical behaviors toward square-wave anodic stripping voltammetric As detection were examined. The difference in intrinsic efficiency for As detection between nanostructured and flat Au electrodes was explained based on the crystallographic orientations of Au surfaces, as examined by the underpotential deposition of Pb. The most efficient As detection performance was obtained with nanoplate Au electrodes, and the effects of the pre-deposition time and interference on As detection of the nanoplate Au electrodes were also investigated.

Significance of Viable but Nonculturable Escherichia coli: Induction, Detection, and Control

  • Ding, Tian;Suo, Yuanjie;Xiang, Qisen;Zhao, Xihong;Chen, Shiguo;Ye, Xingqian;Liu, Donghong
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.3
    • /
    • pp.417-428
    • /
    • 2017
  • Diseases caused by foodborne or waterborne pathogens are emerging. Many pathogens can enter into the viable but nonculturable (VBNC) state, which is a survival strategy when exposed to harsh environmental stresses. Pathogens in the VBNC state have the ability to evade conventional microbiological detection methods, posing a significant and potential health risk. Therefore, controlling VBNC bacteria in food processing and the environment is of great importance. As the typical one of the gram-negatives, Escherichia coli (E. coli) is a widespread foodborne and waterborne pathogenic bacterium and is able to enter into a VBNC state in extreme conditions (similar to the other gram-negative bacteria), including inducing factors and resuscitation stimulus. VBNC E. coli has the ability to recover both culturability and pathogenicity, which may bring potential health risk. This review describes the concrete factors (nonthermal treatment, chemical agents, and environmental factors) that induce E. coli into the VBNC state, the condition or stimulus required for resuscitation of VBNC E. coli, and the methods for detecting VBNC E. coli. Furthermore, the mechanism of genes and proteins involved in the VBNC E. coli is also discussed in this review.