• Title/Summary/Keyword: Chemical Gas Sensor

Search Result 285, Processing Time 0.024 seconds

Analysis Method of Volatile Sulfur Compounds Utilizing Separation Column and Metal Oxide Semiconductor Gas Sensor

  • Han-Soo Kim;Inho Kim;Eun Duck Park;Sang-Do Han
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.125-133
    • /
    • 2024
  • Gas chromatography (GC) separation technology and metal oxide semiconductor (MOS) gas sensors have been integrated for the effective analysis of volatile sulfur compounds (VSCs) such as H2S, CH3SH, (CH3)2S, and (CH3)2S2. The separation and detection characteristics of the GC/MOS system using diluted standard gases were investigated for the qualitative and quantitative analysis of VSCs. The typical concentrations of the standard gases were 0.1, 0.5, 1.0, 5.0, and 10.0 ppm. The GC/MOS system successfully separated H2S, CH3SH, (CH3)2S, and (CH3)2S2 using a celite-filled column. The reproducibility of the retention time measurements was at a 3% relative standard deviation level, and the correlation coefficient (R2) for the VSC concentration was greater than 0.99. In addition, the chromatograms of single and mixed gases were almost identical.

Machine Learning in FET-based Chemical and Biological Sensors: A Mini Review

  • Ahn, Jae-Hyuk
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • This mini review summarizes some of the recent advances in machine-learning (ML)-driven chemical and biological sensors. Specific focus is on field-effect-transistor (FET)-based sensors with a description of their structures and detection mechanisms. Key ML techniques are briefly reviewed for an audience not familiar with the basic principles. We mainly discuss two aspects: (1) data analysis based on ML and (2) ML applied to sensor design. In conclusion, the challenges and opportunities for the advancement of ML-based sensors are briefly considered.

The Interaction of CO to the Co(salen) Complex in to PEDOT:PSS Film and Sensor Application

  • Memarzadeh, Raheleh;Panahi, Farhad;Javadpour, Sirus;Ali, Khalafi-Nezhad;Noh, Hui-Bog;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.1297-1302
    • /
    • 2012
  • The interaction between carbon monoxide (CO) and a cobalt-salen complex (Co(salen)) was studied and applied to detect CO. The metal complex doped PEDOT:PSS film exhibited good sensitivity to CO and differentiate CO from other gases. The response of the composite to CO was reversible (RSD < 5%) change in resistance upon removal of CO gas from the test chamber. The effects of adding Co(salen) in the probe film on the response of the sensor were investigated using AFM, XPS, and FT-IR spectroscopy. The sensitivity of the sensor increased as the Co(salen) concentration enhanced as it increased from 0.0 to 1.5 wt. %, where the highest sensitivity ($%{\Delta}R/R_o$) of $-25.0{\pm}0.05%$ was achieved with 1.0 wt. % Co(salen). The sensor containing probe exhibited a linear response ($R^2$ = 0.983) in the range of 0.5 to 10.0% CO (v/v) $N_2$, and the detection limit was 1.74% CO (v/v) in $N_2$.

Porous Ceramic Fibers: Materials and Applications

  • Kim, Il-Du
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.4-4
    • /
    • 2011
  • Extensive research efforts are directed toward the development of highly sensitive gas sensors using novel nanostructured materials. Among the different strategies for producing sensor devices based on nanosized building blocks, polymeric fiber templating approach which is combined by chemical and physical synthesis routes was attracted much attention. This unique morphology increases the surface area and reduces the interfacial area between film and substrate. Consequently, the surface activity is markedly enhanced while deleterious interfacial effects between film and substrate are significantly reduced. Both effects are highly advantageous for gas sensing applications. In this presentation, facile synthesis of hollow and porous metal oxide nanostructures and their applications in chemical sensors will be discussed.

  • PDF

NO2 gas sensing characteristics of patterned carbon nanotube mats (패턴이 형성된 탄소나노튜브 매트의 이산화질소 감응 특성)

  • Cho, Woo-Sung;Moon, Seung-Il;Paek, Kyeong-Kap;Park, Jung-Ho;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.199-204
    • /
    • 2006
  • Carbon nanotube (CNT) mats grown by thermal chemical vapor deposition on a micromachined substrate with a chrome heater and a diaphragm were investigated as sensing materials of resistive gas sensors for nitrogen dioxide ($NO_{2}$) gas. The aligned CNT mats fabricated into mesh and serpentine shapes by the patterned cobalt catalyst layer. CNT mats showed a p-type electrical resistivity with decreasing electrical resistance upon exposure to $NO_{2}$. All sensors exhibited a reversible response at a thermal treatment temperature of $130^{\circ}C$ for about 5 minutes. The resistance change to $NO_{2}$ of the mesh-shaped CNT mats was larger than that of the serpentine-shaped CNT mats.

Effects of Oxygen Functional Groups introduced onto Activated Carbon Fibers on Gas Sensing Property of Chemical Warfare Agent (활성탄소섬유에 도입된 산소작용기가 유독성 화학작용제 감응특성에 미치는 영향)

  • Kim, Su Hyun;Kim, Min-Ji;Song, Eun Ji;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.719-725
    • /
    • 2019
  • In this study, activated carbon fibers were treated with oxygen plasma to investigate gas sensing properties of the dimethyl methylphosphonate (DMMP), which is a simulant gas of the chemical warfare agent, according to oxygen functional group contents. As the flow rate of oxygen plasma treatment increased, oxygen groups were introduced to the surface of activated carbon fibers from 6.90 up to 36.6%, increasing the -OH group which influences the DMMP gas sensing properties. However, as the flow rate of oxygen plasma increases, the specific surface area tends to decrease because etching on the surface of activated carbon fibers occurs due to active species generated during the oxygen plasma treatment. The resistance change rate of the DMMP gas sensor increased from 4.2 up to 25.1% as the oxygen plasma treatment flow rate increased. This is attributed to the hydrogen bonding between DMMP gas and introduced hydroxyl functional group on activated carbon fibers by the oxygen plasma treatment. Therefore, the oxygen plasma is considered to be one of the important surface treatment methods for detecting chemical warfare agents at room temperature.

Detection Characteristics for the Ultra Lean NOx Gas Concentration Using the MWCNT Gas Sensor Structured with MOS-FET (MOS-FET 구조의 MWCNT 가스센서를 이용한 초희박 NOx 가스 검출 특성)

  • Kim, Hyun-Soo;Lee, Seung-Hun;Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.707-711
    • /
    • 2013
  • Carbon nanotubes(CNT) has strength and chemical stability, greatly conductivity characteristics. In particular, MWCNT (multi-walled carbon nanotubes) show rapidly resistance sensitive for changes in the ambient gas, and therefore they are ideal materials to gas sensor. So, we fabricated NOx gas sensors structured MOS-FET using MWCNT (multi-walled carbon nanotubes) material. We investigate the change resistance of NOx gas sensors based on MOS-FET with ultra lean NOx gas concentrations absorption. And NOx gas sensors show sensitivity on the change of gate-source voltage ($V_{gs}=0[V]$ or $V_{gs}=3.5[V]$). The gas sensors show the increase of sensitivity with increasing the temperature (largest value at $40^{\circ}C$). On the other hand, the sensitivity of sensors decreased with increasing of NOx gas concentration. In addition, We obtained the adsorption energy($U_a$), $U_a$ = 0.06714[eV] at the NOx gas concentration of 8[ppm], $U_a$ = 0.06769[eV] at 16[ppm], $U_a$ = 0.06847[eV] at 24[ppm] and $U_a$ = 0.06842[eV] at 32[ppm], of NOx gas molecules concentration on the MWCNT gas sensors surface with using the Arrhenius plots. As a result, the saturation phenomena is occurred by NOx gas injection of concentration for 32[ppm].

Preparation of the Citrobacter freundii Bio-Sensor for the Determination of Glucose and Its Applications (Glucose 정량을 위한 Citrobacter freundii Bio-Sensor의 개발과 그 응용)

  • Ihn Gwon-Shik;Hong Young-Seuk;Kim Ui-Rak;Jang Seh-Yong;Sohn Moo-Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 1990
  • A bio-sensor for the determination of glucose has been constructed by immobilizing the Citrobacter freundii or its organelle on carbon dioxide gas-sensor. The bacterial sensor was better than organelle in response, but the latter showed a shorter response time. The bacterial sensor gave linearity between 7.0 ${\times}\;10^{-4}$ and 1.0 ${\times}\;10^{-2}$ M glucose with a slope of 42.2 mV/decade in pH 7.0, 0.2 M tris-HCl buffer at 30$^{\circ}C$. The selectivity of this sensor was very high for glucose. Employing for the determination of glucose in serum, the sensor showed a good agreement with a routine analyzer.

  • PDF

Thin Film Gas Sensors Based on Tin Oxide for Acetonitrile (산화주석 기반의 아세토니트릴 검지용 박막형 가스센서)

  • Choi, Nak-Jin;Ban, Tae-Hyun;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Kim, Jae-Chang;Huh, Jeung-Soo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.218-223
    • /
    • 2004
  • Thin film gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas is acetonitrile ($CH_{3}CN$) that is simulant gas of blood agent gas. Sensing materials are $SnO_{2}$, $SnO_{2}$/Pt, and (Sn/Pt)oxidation with thickness from $1000{\AA}$ to $3000{\AA}$. Sensor was consisted of sensing electrode with interdigit (IDT) type in front side and a heater in back side. Its dimension was $7{\times}10{\times}0.6mm^{3}$. Fabricated sensor was measured as flow type and monitored real time using PC. The optimal sensing material for $CH_{3}CN$ was {Sn($3000{\AA}$)/Pt($30{\AA}$)}oxidation and its sensitivity and operating temperature were 30%, $300^{\circ}C$ in $CH_{3}CN$ 3 ppm.

Gas Distribution Mapping and Source Localization: A Mini-Review

  • Taehwan Kim;Inkyu Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.75-81
    • /
    • 2023
  • The significance of gas sensors has been emphasized in various industries and applications, owing to the growing significance of environmental, social, and governance (ESG) management in corporate operations. In particular, the monitoring of hazardous gas leakages and detection of fugitive emissions have recently garnered significant attention across several industrial sectors. As industrial workplaces evolve to ensure the safety of their working environments and reduce greenhouse gas emissions, the demand for high-performance gas sensors in industrial sectors dealing with toxic substances is on the rise. However, conventional gas-sensing systems have limitations in monitoring fugitive gas leakages at both critical and subcritical concentrations in complex environments. To overcome these difficulties, recent studies in the field of gas sensors have employed techniques such as mobile robotic olfaction, remote optical sensing, chemical grid sensing, and remote acoustic sensing. This review highlights the significant progress made in various technologies that have enabled accurate and real-time mapping of gas distribution and localization of hazardous gas sources. These recent advancements in gas-sensing technology have shed light on the future role of gas-detection systems in industrial safety.