• Title/Summary/Keyword: Chemical Gas Sensor

Search Result 285, Processing Time 0.029 seconds

Short Review on Quartz Crystal Microbalance Sensors for Physical, Chemical, and Biological Applications

  • Il Ryu, Jang;Hoe Joon, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.389-396
    • /
    • 2022
  • Quartz crystal microbalance (QCM) based sensors are used for various applications owing to advantages such as excellent accuracy and precision, rapid response, and tiny footprint. Traditional applications of QCM-based sensors include biological sensing and thin-film thickness monitoring. Recently, QCMs have been used as functional material for novel physical and chemical detections, and with improved device design. QCM-based sensors are garnering considerable attention in particulate matter sensing and electric nose application. This review covers the challenges and solutions in physical, chemical, and biological sensing applications. First, various physical sensing applications are introduced. Secondly, the toxic gas and chemical detection studies are outlined, focusing on introducing a coating method for uniform sensing film and sensing materials for a minimal damping effect. Lastly, the biological and medical sensing applications, which use the monomolecularly decorating method for biomolecule recognition and a brief description of the overall measuring system, are also discussed.

Room Temperature Hydrogen Gas Sensor Based on Carbon Nanotube Yarn (상온감지 가능한 탄소나노튜브 방적사 기반의 수소 감지 센서)

  • Kim, Jae Keon;Lee, Junyeop;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.132-136
    • /
    • 2018
  • We report the development of a room-temperature hydrogen ($H_2$) gas sensor based on carbon nanotubes (CNT) yarn. To detect $H_2$ gas in room temperature, a highly ordered CNT yarn was placed on a substrate from a spin-capable CNT forest, followed by the deposition of a platinum (Pt) layer on surface of the CNT yarn. To examine the effect of the Pt-layer on the response of the CNT sensor, a comparative sensing performance was characterized on both the Pt deposited and non-deposited CNT yarn at room temperature. The Pt-CNT yarn yielded high response, whereas the non-deposited CNT yarn showed negligible response for $H_2$ detection at room temperature. Pt is a reliable and efficient catalyst that can substantially improve the detection of $H_2$ gas by chemical sensitization via a "spillover" effect. It can be efficiently utilized to increase the sensitivity and selectivity as well as to obtain fast response and recovery times.

Basic Studies for the Development of the $NO_2$ Gas Sensor Using Functional Organic Ultrathin Film (기능성 유기 초박막을 이용한 $NO_2$ 가스센서 개발을 위한 기초 연구)

  • Sohn, B.C.;Rim, B.O.;Kim, Y.I.;Sohn, T.W.;Shin, D.M.;Ju, J.B.;Chung, G.Y.;Kim, Y.K.;Kang, W.H.;Lee, B.H.
    • Journal of the Korean Applied Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.125-131
    • /
    • 1995
  • Ultra thin films of Tetra-3-hexadecylsulphamoylcopperphthalocyanine(HDSM-CuPc) were formed on various substrates by Langmuir-Blodgett method, where HDSM-CuPc was synthesized by attaching long-chain alkylamine(hexa-decylamine) to CuPc. The reaction product was identified with FT-IR, UV-visible absorption spectroscopies, elemental analysis and thin layer chromatography. The formation of Ultrathin Langmuir-Blodgett(LB) films of HDSM-CuPc was confirmed by FT-IR and UV-visible spectroscopies. A quartz piezoelectric crystal coated with LB films of HDSM-CuPc was examined as a gas sensor for $N0_2$ gas. HDSM-CuPc LB films were transferred to a quartz crystal microbalance(QCM) in the form of Z-type multilayers. Response characteristics of film-coated QCM to $NO_2$ gas concentrations over a range of $100{\sim}600ppm$ have been tested with a thickness of $5{\sim}20$ layers of HDSM-CuPc. Changes in frequency by adsorption of $NO_2$ were increased With the number of LB layers and $NO_2$ concentration, but the response time was slow.

Optimal Sensor Placement for Rapid Detecting in Chemical Leak Accident (화학물질의 누출에서 빠른 감지를 위한 센서 배치 최적화)

  • Cho, Jaehoon;Kim, Hyunseung;Kim, Taeok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.66-71
    • /
    • 2016
  • Nowadays, a number of sensors which are placed in industrial complex are monitoring areas involving chemical leak and other faults. However, even in the presence of the sensors, chemical leaks, sometimes involving huge amount of chemicals, continuously led to big losses in the industrial complex. In most industries, sensor installation has been performed using past experience or using senor manufacturers' guideline; which leads to poor performance of the installed sensor grid. Therefore, we investigate an optimal placement methodology of point sensors for rapid detention and response when chemical leaks happen. This research suggests a generalized formulation suitable for the optimized decision making of minimizing number of sensors to be placed and increasing the fraction of covered scenarios under assumption of negligible effect of other structures. The proposed method has been verified for suitable performance for simple leak scenario simulations, by achieving the safety objectives and guaranteeing safe process operations.

Detection of Blood Agent Gas Using $SnO_2$ Thin Film Gas Sensor

  • Choi, Nak-Jin;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Lee, Duk-Dong;Bahn, Tae-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.69-75
    • /
    • 2004
  • In this study, thin film gas sensor based on tin oxide was fabricated to examine its characteristics. Target gas is acetonitrile ($CH_3$CN) which is a blood simulant for the chemical warfare agent. Sensing materials are SnO$_2$ SnO$_2$/Pt, and Sn/Pt with thickness from 1000 to 3000 $\AA$. The sensor consists of a sensing electrode with inter-digit (IDT) type in front side and a heater in rear side. Resistance changes of sensing materials are monitored on real time basis using a data acquisition board with a 12-bit analog to digital converter. Sensitivities are measured at different operating temperatures also with different gas concentrations and film thickness. The high sensitivity is obtained for Sn (3000 $\AA$)/Pt (30 $\AA$) at 30$0^{\circ}C$ for 3 ppm. Response and recovery times were about 40 and 160 s, respectively. Repetition measurements showed very good results with $\pm$3% in full scale range.

Sensing and Identification of Health Hazardous Molecular Components using Surface-Enhanced Raman Spectroscopy: A Mini Review

  • Pratiksha P. Mandrekar;Moonjin Lee;Tae-Sung Kim;Daejong Yang
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.259-266
    • /
    • 2023
  • The use of various adulterants and harmful chemicals is rapidly increasing in various sectors such as agriculture, food, and pharmaceuticals, and they are also present in our surroundings in the form of pollutants. The regular and repeated intake of harmful chemicals often adversely affects human health. The prolonged exposure of living beings to such adverse components can lead to severe health complications. To avoid the unlimited utilization of these chemical components, a sensing technology that is sensitive and reliable for low-concentration detection is beneficial. Surface-enhanced Raman spectroscopy (SERS) is a powerful method for identifying low-range concentrations of analytes, leading to great applications in molecular identification, including various diagnostic biomarkers. SERS in chemical, gas, and biological sensors can be an excellent approach in the sensing world to achieve rapid and multiple-analyte detection, leading to a new and efficient approach in healthcare monitoring.

Plant Tissue Sensor for Determination of Cytidine (시티딘 정량을 위한 식물조직 센서)

  • Gwon Shik Ihn;Chin Kap Chung;Bong Weon Kim;Young Guk Jeon
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.218-222
    • /
    • 1992
  • Rose tissue containing cytidine deaminase converts cytidine to uridine and ammonia gas. Rose tissue sensor was constructed by immobilizing 50mg of a rose petal tissue on an NH3 gas sensor and the optimum condition of the sensor for the determination of cytidine was investigated. The tissue sensor showed a linear range of$7.0 {\times} 10^{-4}$$1.0{\times} 10^{-2}$M cytidine with a slope of 53 mV/decade in 0.2 M phosphate buffer, pH 8.4 at 37$^{\circ}C$. The detection limits were $3.0{\times}10^{-4}$ M and relative standard deviation was 3.4%. This sensor showed an excellent selectivity among various nucleosides and amino acids.

  • PDF

Pt-AlGaN/GaN HEMT-based hydrogen gas sensors with and without SiNx post-passivation

  • Vuong, Tuan Anh;Kim, Hyungtak
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1033-1037
    • /
    • 2019
  • GaN-based sensors have been widely investigated thanks to its potential in detecting the presence of hydrogen. In this study, we fabricated hydrogen gas sensors with AlGaN/GaN heterojunction and investigated how the sensing performance to be affected by SiN surface passivation. The gas sensor employed a high electron mobility transistors (HEMTs) with 30 nm platinum catalyst as a gate to detect the hydrogen presence. SiN layer was deposited by inductively-coupled chemical vapor deposition as post-passivation. The sensors with SiN passivation exhibited hydrogen sensing characteristics with various gas flow rates and concentrations of hydrogen in inert background gas at $200^{\circ}C$ similar to the ones without passivation. Aside from quick response time for both sensors, there are differences in sensitivity and recovery time because of the existence of the passivation layer. The results also confirmed the dependence of sensing performance on gas flow rate and gas concentration.

Ethanol Gas Sensing Characteristics of Conducting Polymer Sensor Using Impedance (Impedance를 이용한 전도성고분자 센서의 에탄올 가스 감응특성)

  • Lee, Kyung-Mun;Yu, Joon-Boo;Jun, Hee-Kwon;Lee, Byung-Soo;Lee, Duk-Dong;Huh, Jeung-Soo
    • Korean Journal of Materials Research
    • /
    • v.13 no.3
    • /
    • pp.155-159
    • /
    • 2003
  • The polypyrrole and polyaniline thin film sensors which were made by chemical polymerization were employed to detect ethanol gas. With a single sensor element we can obtain characteristic patterns of behaviour across a very wide frequency range when measuring either resistance or capacitance. Impedance spectroscopy was employed to study the gas sensing behavior of both capacitance and resistance based sensors with conducting polymer as the active sensing element.

3-dimensional nanostructured ZnO gas sensor (3차원 ZnO 나노구조체 가스센서)

  • Park, Yong-Wook;Shin, Hyun-Yong;Yoon, Seok-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.356-360
    • /
    • 2010
  • Due to the high surface-to-volume ratio, the 3-dimensional(3D) nanostructures of metal oxides are regarded as the best candidate materials for the chemical gas sensors. Here we have synthesised flower-like 3D zinc oxide nanostructures through a simple hydrothermal route. Specific surface area of the 3D zinc oxide nanostructures synthesised in different pH values from 9.0 to 12.0 were evaluated by using a BET analyzer and the results were compared with that of a zinc oxide thin film fabricated by rf sputtering. Using interdigitated electrodes, superior CO gas sensing properties of the 3D zinc oxide nanostructures on the ZnO thin film to those of the ZnO thin film were demonstrated.