• Title/Summary/Keyword: Check System

Search Result 3,298, Processing Time 0.034 seconds

Constructing a Performance Evaluation Model of an R&D Module in Quality Management System Using QFD (QFD를 이용한 품질경영 시스템의 개발모듈에 대한 이행도 평가모형)

  • 류문찬;우성권
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.2
    • /
    • pp.1-10
    • /
    • 2002
  • A performance evaluation model of an R&D module in the quality management system for M Company Is constructed using QFD. The company produces telecommunication devices and employs the performance evaluation model based on ISO 9000 family. However, the model has some problems, one of them is that all check items are regarded as equally important Customer requirements are gathered from internal customers and QFD is utilized to obtain weights for each check item.

Computer Aided Design Verification System of CAD Drawings Drawn with CAD System(The Case of Considering to Annular Parts) (CAD시스템을 이용하여 작성한 도면의 설계검증시스템(회전체를 고려한 경우))

  • 이성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.593-597
    • /
    • 1996
  • This paper describes a method for drawing check of dimension errors, such as deficiency and redundancy of dimensions, input-errors in dimension figures and symbols, etc. The logic for finding dimensional errors is written by using the Turbo C language. Checking for deficiency and redundancy of global dimensions has been performed applying Graph Theory. Especialy, this paper gives an account of checking method for annular parts.

  • PDF

A High Power Micropump Using Active Check Valves Driven by Piezoelectric Actuators (압전구동 능동형 체크밸브를 이용한 고출력 마이크로펌프)

  • Kang, Jung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.4
    • /
    • pp.39-47
    • /
    • 2005
  • In this paper, a novel high power micropump using active check valves in place of conventional passive check valves employed at the inlet and outlet ports is presented. It actively controls open/close motion of check valves using piezoelectric actuator for expansion/contraction of pump chamber. A prototype micropump having an effective size of $17mm{\times}8mm{\times}11mm$ is fabricated. Frequency-dependent flow rate characteristics, bi-directional flow characteristics and load characteristics are experimentally investigated using a timing control method for valve closing motion. From the obtained experimental results, it is ascertained that optimal values of the phase shift compared to the voltage to drive pump chamber are $15^{\circ}$ for inlet check valve and $195^{\circ}$ for outlet. Based on the obtained results, a sheet-type active shuttle valve that has a unified valve-body for inlet and outlet check valves is proposed. A micropump with an effective size of $10mm{\times}10mm{\times}10mm$ is fabricated and the basic characteristics are experimentally investigated.

  • PDF

High-output Piezoelectric Micropump Using Active Check Valves (능동형 체크 밸브를 이용한 고출력 압전 마이크로펌프)

  • Park, Jung-Ho;Yoshida, Kazuhiro;Yokota, Shinichi;Ham, Young-Bog;Yun, So-Nam
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1864-1869
    • /
    • 2003
  • A novel piezoelectric micropump using active check valves in place of conventional passive check valves in inlet and outlet has been proposed and investigated. It actively controls open/close motion of check valves using piezoelectric actuator for expansion/contraction of pump chamber. In this paper, bi-directional flow characteristics and load characteristics are experimentally investigated using an adequate timing control for valve closing motion with a prototype micropump fabricated with the effective size of $17{\times}8{\times}11mm^{3}$. From the experimental results, it is ascertained that optimal values of phase shift against voltage to drive pump chamber for realization of a miniaturized but powerful micropump, are $15^{\circ}$ in inlet check valve and $195^{\circ}$ in outlet. Based on the obtained results, a sheet-type active shuttle valve that has a unified valve-body for inlet and outlet check valves is proposed. A micropump with the effective size of $10{\times}10{\times}10mm^{3}$ is fabricated and basic characteristics are experimentally investigated.

  • PDF

Development of Check-list for BIM Based Architectural Design Quality Check (BIM 기반 건축설계 품질검토를 위한 체크리스트 개발 연구)

  • Choi, Jungsik;Kim, Inhan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.3
    • /
    • pp.177-188
    • /
    • 2013
  • The construction industry consists of various and massive architectural information as an architectural process includes a variety of design stages with cooperation of many disciplines. Particularly, architectural information is generated and managed through the life cycle of a building, from conceptual design stage to the construction and maintenance. A Building Information Model (BIM) serves as a shared knowledge resource for information about a facility forming a reliable basis for decisions during its life-cycle from inception onward. BIM technology accomplished quantitative development being utilized in various disciplines. However, it is necessary to develop environment and requirement for qualitative improvement of BIM based project. Particularly, requirement is very important for architectural design evaluations. The purpose of this study is to develop and apply of quality control check-list for improving the quality of architectural design in BIM environments. To achieve this purpose, the authors have investigated case study for open BIM data quality control (software, guideline and application case) and classified quality control targets according to physical/logical quality control and data quality. In addition, the authors have defined open BIM based quality control process and developed quality control check-list. Finally, the authors have developed automatic quality check system using requirements for efficient quality control based on open BIM.

A Basic Study for Selecting the Project Risk Management Check List (PRM(Project Risk Management) 체크리스트 항목 선정을 위한 기초연구)

  • Bang, Hong-Song;Kim, Jin-Kuk;Choi, Byung-Ju;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.99-100
    • /
    • 2017
  • In today's builders PRM(Project Risk Management) for Risk Management to fill out the competitive advantage, by and return it safe and take. But PRM has different standards for each construction company and can also see that even the list. In this study, consideration existing research through PRM by developing a list of check list to proceed to the basic research to help. In this study, PRM by creating a basis of the check list disclosed to the frame of reference. The results of this study by PRM of the check list for field application management system to provide a basis to build.

  • PDF

Formal Verification of PLC Program Safety in Manufacturing Automation System (생산자동화시스템 PLC 제어프로그램의 안전성 정형검증에 관한 연구)

  • Park, Chang Mok
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.179-192
    • /
    • 2015
  • In an automated industry PLC plays a central role to control the automation system. Therefore, fault free operation of PLC controlled automation system is essential in order to maximize a firm's productivity. A prior test of control system is a practical way to check fault operations, but it is a time consuming job and can not check all possible fault operation. A formal verification of PLC program could be a best way to check all possible fault situation. Tracing the history of the study on formal verification, we found three problems, the first is that a formal representation of PLC control system is incomplete, the second is a state explosion problem and the third is that the verification result is difficult to use for the correction of control program. In this paper, we propose a transformation method to reproduce the control system correctly in formal model and efficient procedure to verify and correct the control program using verification result. To demonstrate the proposed method, we provided a suitable case study of an automation system.

A Method for Automatic Generating Check Sheet of Jig and Die in Automobile Components Using CAD Model (CAD모델을 이용한 자동차 프레스 부품 검사 치구 체크 시트의 자동 생성방법)

  • 박성도;이철수
    • Korean Journal of Computational Design and Engineering
    • /
    • v.7 no.2
    • /
    • pp.102-109
    • /
    • 2002
  • This paper presents a method for automatic generating of check sheet to measure deep-drawn sheet metal. By using polyhedral model of CAD, the proposed procedure calculates measuring points automatically. The results of measure are exported to MS-Excel. The proposed method is implemented by API functions and C language using SPEED plus CAD/CAM system and MS-Window OLE.

Risk Management and Strategies in Airport Security Check (공항 보안검색에 있어서의 위험관리와 대응과제)

  • Kim, Jae-Woon
    • Korean Security Journal
    • /
    • no.34
    • /
    • pp.89-113
    • /
    • 2013
  • Travel by airplane using airport in globalized modern society is familiar to our life but such airport can be a target of terrorists who would threaten our safety. However, aviation terrorism which is represented by 9.11 terror gives horror beyond our imagination to modern people. Since the first airplane hijacking in Peru in 1931 happened, security organization in each nation has taken various prevention measures to block aviation terrorism. The most realistic measures to prevent aviation terrorism would be security check activity to control approach of terrorist that passengers on airplane and cargos are checked to find out dangerous article like explosive etc. But security check activity in Korea shifted to security check activity focused on private security for efficiency of airport operation differently from security check activity in advanced countries where public interests is strengthened according to risk of terror after 9.11 system. That is, since Incheon airport opened in March 2001, security check system focused on the police was changed. Now Incheon international airport Corporation instructs and supervises security check job and private security personnel are in charge of actual security check activity. But this check system has limitation in blocking terror activity by terrorists which is systematized and intelligent as time passes due to deteriorated job satisfaction of private security personnel and confusing supervising system. Accordingly, it is suggested to introduce risk management skill which is one of management strategy of private corporation for security check activity to prevent terror activity. With this skill, risk factors of aviation terror are identified and analyzed regularly, and each process such as setting of priority, activity to reduce risk, and assessment of security is carried out. And it would be necessary to do efforts, for example, to properly change level of security check according to threat of terror such as to place policeman at airport security in case threat of terror is severe. On the other hand, it is necessary to establish national police organization for good communication of security check activity in field and supervising function, which can encourage systematization and specialization of aviation security job.

  • PDF

Pressure Transfer Analysis and Experimental Verification of Thin Plate Spring Type Check Valve Considering P-delta Effect (P-delta 효과를 고려한 박판 스프링 형 체크밸브의 압력전달 해석 및 실험적 검증)

  • Hwang, Yong-Ha;Nguyen, Anh Phuc;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.32-39
    • /
    • 2018
  • In this paper, the calculation of the theoretical pressure transfer ratio due to the deformation of the thin-plate spring type check valve applied to the small piezoelectric-hydraulic pump was carried out. A thin-plate check valve is a flexible body that is deformed by an external force. The deformation of the check valve affects the rate at which the chamber pressure is transferred to the load pressure. The theoretical pressure transfer ratio for each model was calculated to compare the difference between the assumption that the thin-plate check valve is a rigid body and that of the flexible body model. The P-delta effect was considered for the calculation of the pressure transfer ratio of the flexible check valve model. In addition, a verification test for the calculated pressure transfer ratio obtained by considering the deformation of the flexible check valve model was carried out. The load pressure was measured by applying a thin-plate and ball-thin plate spring type check valves, respectively. The experimental pressure transfer ratio was calculated using the respective load pressure obtained from the experiments. The validity of the pressure transfer analysis of the check valve, taking into consideration the P-delta effect, was verified by comparing it with the theoretically calculated pressure transfer ratio.