• Title/Summary/Keyword: Check Sheet

Search Result 89, Processing Time 0.027 seconds

A Method of Calculating Baseline Productivity by Reflecting Construction Project Data Characteristics (건설 프로젝트 데이터 특성을 반영한 기준생산성 산정 방법)

  • Kim Eunseo;Kim Junyoung;Joo Seonu;Ahn Changbum;Park Moonseo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.3
    • /
    • pp.3-11
    • /
    • 2023
  • This research examines the need for a quantitative and objective method of calculating baseline productivity in the construction industry, which is known for its high volatility in performance and productivity. The existing literature's baseline productivity calculation methods rely heavily on subjective criteria, limiting their effectiveness. Additionally, data collection methods such as the "Five-minute Rating" are costly and time-consuming, making it challenging to collect detailed data at construction sites. To address these issues, this study proposes an objective baseline calculation method using unimpacted productivity BP, a work check sheet to systematically record detailed data, and a data collection and utilization process that minimizes cost and time requirements. This paper also suggests using unimpacted productivity BP and comparative analysis to address the objectivity and reliability issues of existing baseline productivity calculation methods.

Survey of Actual Conditions of Material Safety Data Sheet and Quantitative Risk Assessment of Toxic Substances : Substitutes for Degreasing Agents (일부 대체세정제 제조업체의 물질안전보건자료의 실태와 그 화학물질의 유해성 평가에 관한 연구)

  • Yoon, Chong-Guk;Jeon, Tae-Won;Chung, Chin-Kap;Lee, Myung-Hee;Lee, Sang-Il;Cha, Sang-Eun;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.18-26
    • /
    • 2000
  • Since the regulation of MSDS (Material Safety Data Sheets) had started from July 1996, employers were required to furnish MSDS for the chemicals in use in their workplace. However, many MSDS did not contain upright information for the chemicals, and they were not updated regularly, and were not written in the standard format required by the Industrial Safety and Health Act (ISHA). The purposes of this study were 1) to examine the reliability of MSDS for mixed solvents, 2) to provide reliable MSDS to employers or employees, 3) to find out any difficulties in implementing MSDS after the initiation, and 4) to promote regular MSDS updating and to ensure the reliability of MSDS for chemical manufacturers. To check the reliability of MSDS of mixed chemicals, 21 samples of mostly degreasing solvents were collected along with their MSDS from the work place. The samples were analyzed by gas chromatography-mass selective detector(GC-MSD). Their components were classified as saturated hydrocarbon, cyclic hydrocarbon, aromatics, and halogen containing hydrocarbon, and the amount of each class were measured. Manufacture's MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. Finally, each item of MSDS was evaluated whether the MSDS correspond to the regulation required by ISHA. The results were following: 1) most of the degreasing solvents in MSDS were incorrect in their composition and contents, 2) the information in the MSDS including hazard classification, exposure level, toxicity, regulatory information were incorrectly provided, and 3) some MSDS did not disclose carcinogens in their MSDS. Continuous monitoring of MSDS was required to ensure reliability of MSDS. The Chemicals containing hydrocarbons from C10-C15 need to be tested to provide toxicity data. In addition, governmental support for providing correct MSDS was recommended to ensure reliability of MSDS. The MSDS regulation relating to the confidential business information may need to be revised to ensure reliability of MSDS.

  • PDF

RF and Optical properties of Graphene Oxide

  • Im, Ju-Hwan;Rani, J.R.;Yun, Hyeong-Seo;O, Ju-Yeong;Jeong, Yeong-Mo;Park, Hyeong-Gu;Jeon, Seong-Chan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.68.1-68.1
    • /
    • 2012
  • The best part of graphene is - charge-carriers in it are mass less particles which move in near relativistic speeds. Comparing to other materials, electrons in graphene travel much faster - at speeds of $10^8cm/s$. A graphene sheet is pure enough to ensure that electrons can travel a fair distance before colliding. Electronic devices few nanometers long that would be able to transmit charge at breath taking speeds for a fraction of power compared to present day CMOS transistors. Many researches try to check a possibility to make it a perfect replacement for silicon based devices. Graphene has shown high potential to be used as interconnects in the field of high frequency electrical devices. With all those advantages of graphene, we demonstrate characteristics of electrical and optical properties of graphene such as the effect of graphene geometry on the microwave properties using the measurements of S-parameter in range of 500 MHz - 40 GHz at room temperature condition. We confirm that impedance and resistance decrease with increasing the number of graphene layer and w/L ratio. This result shows proper geometry of graphene to be used as high frequency interconnects. This study also presents the optical properties of graphene oxide (GO), which were deposited in different substrate, or influenced by oxygen plasma, were confirmed using different characterization techniques. 4-6 layers of the polycrystalline GO layers, which were confirmed by High resolution transmission electron microscopy (HRTEM) and electron diffraction analysis, were shown short range order of crystallization by the substrate as well as interlayer effect with an increase in interplanar spacing, which can be attributed to the presence of oxygen functional groups on its layers. X-ray photoelectron Spectroscopy (XPS) and Raman spectroscopy confirms the presence of the $sp^2$ and $sp^3$ hybridization due to the disordered crystal structures of the carbon atoms results from oxidation, and Fourier Transform Infrared spectroscopy (FTIR) and XPS analysis shows the changes in oxygen functional groups with nature of substrate. Moreover, the photoluminescent (PL) peak emission wavelength varies with substrate and the broad energy level distribution produces excitation dependent PL emission in a broad wavelength ranging from 400 to 650 nm. The structural and optical properties of oxygen plasma treated GO films for possible optoelectronic applications were also investigated using various characterization techniques. HRTEM and electron diffraction analysis confirmed that the oxygen plasma treatment results short range order crystallization in GO films with an increase in interplanar spacing, which can be attributed to the presence of oxygen functional groups. In addition, Electron energy loss spectroscopy (EELS) and Raman spectroscopy confirms the presence of the $sp^2$ and $sp^3$ hybridization due to the disordered crystal structures of the carbon atoms results from oxidation and XPS analysis shows that epoxy pairs convert to more stable C=O and O-C=O groups with oxygen plasma treatment. The broad energy level distribution resulting from the broad size distribution of the $sp^2$ clusters produces excitation dependent PL emission in a broad wavelength range from 400 to 650 nm. Our results suggest that substrate influenced, or oxygen treatment GO has higher potential for future optoelectronic devices by its various optical properties and visible PL emission.

  • PDF

A Study on the Nursing Time in Nursing Units in Hospital to Applied Computer System (전산 시스템이 도입된 일개 종합병원 간호단위의 간호시간 산정에 관한 연구)

  • 장춘자;강익화;이은자;김병연;이민숙
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.441-456
    • /
    • 1995
  • This study was done to determine direct and in-direct nursing time in nursing units in hospital to ap-plied computer system and expect that those results contribute to measure efficiency of nursing practice and planning of nursing manpower. The design for study was a descriptive study. The study results are as follows. 1. Patients admitted to the Internal Medicine and General Surgery units were grouped into four. Group Ⅰ, 32.9% of the total patients, consisted patients whose condition was considered minor Group Ⅱ, 26.1%, was of those whose condition was considered moderate, Group Ⅲ, 41. 8%, moderate severe and Group Ⅳ, 29.2% the most severe. 2. Nursing intervention times by care type were as follows four minutes spent for suction eight minutes, for simple position change, ten minutes, for sheet change, seven minutes for a hot or cool compress, six minutes for dressing change, four minutes for Ⅰ.M. injection, six minutes for patient health education and five minutes for body temperature check. 3. Direct care time by patient group revealed the following : Group Ⅰ rquired 191.4 minutes, Group Ⅱ required 331.1 minutes, Group Ⅲ rquired 499.4 minutes, and Group Ⅳ rquired 1328.0 minutes. 4. The ratio of time for adequate nursing care and direct care time in the Internal Medicine and Goneral Surgery units was 67.4%-83.4% and 94.7%-99.3% in the Intensie Care Unit. 5. Average daily direct care time per patient was 5.5 hours in the Internal Medicine unit and 11.5 hours in the Intensive Care Unit. 6. Time spent in indirect care was 48.3 minutes for computer recording,34.8 minutes for giving and receiving patient information for shift duty, 28.0 minutes for eating and resting time, 26.6 minutes for transfering and identifying patients, 25.6 minutes for identifying Doctor's order, 23.9 minutes for recording vital signs. 7. Time spent in indirect care was 282.2 minutes by head nurses (charge nurses), 258.7 minutes by nurses and 261.6 minutes by nurse aids. 8. The average nurse's workload was 9.3 hours and daily indirect nursing time required 46.3%-50. 5% of above mentioned workload time. .9. The average daily indirect care time per patient was expected to be 57.7 minutes in the Internal Medicine unit and 3.3 hours in the Intensive Care Unit.

  • PDF

2-Dimensional Equilibrium Analysis and Stability Analysis of Geotextile Tube by Hydraulic Model Test (지오텍스타일 튜브의 2차원 평형해석 및 수리모형시험을 통한 안전성 분석)

  • 신은철;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.251-260
    • /
    • 2002
  • Geotextile tribes are made of sewn geotextile sheet and hydraulically or mechanically filled with dredged materials. They have been applied in hydraulic and coastal engineering in recent years(shore protection structure, detached breakwater, groins, and jetty). Therefore, it is composed of geotextile and confined fill material. Recently, new preliminary design criteria supported by model and prototype tests, and some stability analysis calculations have been studied. The stability analysis of geotextile tube is composed of geotechnical and hydrodynamic analysis. The stability check points are sliding failure, overturning, bearing capacity failure against the wave attack. In this paper are presented the stability analysis method by empirical equation and 2-D equilibrium analysis for geotextile tube. Also, the hydraulic model tests were performed to verify the theoretical stability analysis with geotextile tube shape, filling ratio, significant wave height, and so on. The results of this study show that the stability of geotextile tube depends on the tube shape, contact area, projection area. The theoretical analysis and hydraulic model test show almost the same results.

A Study on Risk Analysis and Acident Prevention Heater Interlock By-pass (Heater interlock by-pass로 인한 위험분석 및 사고방지에 대한 연구)

  • Son Jae-geun;Park Kyo-Shik;Kang Tae-Yeon;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.24-27
    • /
    • 2003
  • In this paper it was investigated 15 heaters of CDU plant heater, NCC plant heater, CO plant heater, Aromatic plant heater and so on while running in our country. It was also analysed the standard of operation procedure, the action in alarm, the interlock system, the operating situation of the interlock by-pass and major accident about the heater and so on. This paper presents the installation of the on-line monitoring, the additional installation of the local pressure gauge and temperature gauge, the check in starting operation,'the management of the interlock by-pass, the change of manufacturer causing the disorder of instrument sensor, the management method of DCS alarm for methods of the interlock prevention and facilities improvement. It was few information about the heater interlock in the inside and outside of the country We mainly have studied with reflecting the opinion of the operator and manager on site, the sheet of process trouble and operation procedure and so on. we think that the accident relating to the interlock will significantly reduce if the companies apply the conclusion of this study(i.e. methods of the interlock prevention and facilities improvement).

  • PDF

Damage Status of Turnout System with Wooden Sleeper of Concrete Track on Urban Transit (도시철도 콘크리트궤도 목침목 분기기의 손상현황)

  • Choi, Jung-Youl;Han, Kyung-Sung;Bong, Jae-Gun;Jang, Cheol-Ju;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.379-385
    • /
    • 2019
  • The purpose of this study is to investigate the damage status of wood sleepers on concrete track of urban transit at different locations and to analyze the causes of damages. In addition, the turnout maintenance history during the service period of about 24 years was analyzed in conjunction with the train passing tonnage and that was to compare the current repair history. The most frequent damage components were rail, tie plate, spike and wooden sleeper. And, the damage caused by the defect of the rail fastening system such as spike and tie plate according to the deformation of the wooden sleeper was analyzed as the main type of damage. As a result, the damage of track components of turnout system was on the increase because they are directly affected by the train passing tonnage. The supplementary points of the check sheet for current turnout maintenance were derived and the improvement proposal was suggested based on the research results.

Synthesis of Reduced Graphene-metal Hybrid Materials via Ion-exchange Method and its Characterization (이온교환법에 의한 환원 그래핀-금속 하이브리드 소재의 합성 및 특성)

  • Park, Aeri;Kim, Sumin;Kim, Hyun;Han, Jong Hun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.25-37
    • /
    • 2020
  • In this study, hybridization of graphene oxide and metal was carried out by the functional groups containing oxygen and thermal treatment for reduction in order to enhance the electrical conductivity and magnetic properties of graphene materials. Graphene-metal hybrid materials were synthesized using the oxygen-containing functional groups (-OH, -COOH and so on) on the surface of graphene oxide by replacing them with metal ions via ion exchange method as well as thermal reduction. The metals used in this study were Fe, Ag, Ni, Zn, and Fe/Ag, and it was confirmed that metal particles of uniform size were well dispersed on the graphene surface through SEM, TEM, and EDS. All of the metal particles on the graphene surface had an oxide-crystalline structure. To check the electrical properties, sheet resistance of the rGO-metal hybrid sample was measured on the PET film made by the dip-coating, and the specific resistance was calculated by measuring the thickness of the specimen through SEM. As a result, the specific resistance was in the range of 2.14×10-5 and 3.5×10-3 ohm/cm.

Effect of Health Promotion and Characteristics of Elderly used Day Care Service in Community Health Practitioner's Post (보건진료소의 주간보호실 이용노인의 특성과 건강증진 정도)

  • Jeong, In-Suk;Cho, Yoo-Hyang;Park, Yoon-Chang
    • Journal of agricultural medicine and community health
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2002
  • This study was taken to provide data for the approaches of day care service for the elderly in community health practitioner's post through the study on the utilization rate, characteristics and health promotion that the elderly used the day care services. Data collection used three records that case management in take sheet, dementia check list and ADL record during the one year, from June 21, 2001 to June 30, 2002. During the one year, the elderly used day care services were 119 persons that 26.9% of the total elderly population, 1.5 time per used the elderly, and female elderly(88.9%) more used than male elderly. 39.5%of the elderly user have chronic diseases that was arthritis and hypertension and etc. 41.2% of the elderly users have dementia state that score was $17.39{\pm}7.17$(handicapped elderly), $18.43{\pm}7.36$(healthy elderly), but statistically not significant PADL score was $2.18{\pm}0.55$(handicapped elderly), $2.78{\pm}0.30$(healthy elderly), IADL score was $1.78{\pm}0.51$(handicapped elderly), $2.47{\pm}0.60$(healthy elderly) that were statistically significant. One year later, PADL and IADL of the elderly users were improved that statistically significant(p=0.01). The elderly users were wanted rehabilitation service(22.2%), talking service(20.6%), bath service(12.7%), food service(9.5%) of day care services in CHP's post. We are recommended that day care service for the elderly in CHP's post was very useful and contributed to promote ADL functions.

  • PDF