• 제목/요약/키워드: Characteristic variation

검색결과 1,461건 처리시간 0.026초

히트펌프 시스템의 시설원예 적용에 관한 실험적 연구 (An Experimental Study on Applying Heat Pump System to Facility Horticulture House)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

프린트형 안테나의 접지면 크기에 따른 안테나 특성 변화에 관한 연구 (A Study on the Antenna Characteristic Variation according to Ground Plane Size of Print Type Antenna)

  • 송면규;양규식
    • 한국정보통신학회논문지
    • /
    • 제4권2호
    • /
    • pp.365-370
    • /
    • 2000
  • 본 논문에서는 접지면의 크기가 안테나의 성능에 미치는 영향을 분석하기 위하여 기존의 프린트형 안테나의 특성 개선 요구에 부응한 안테나를 설계ㆍ제작하여 프린트형 안테나의 접지면의 크기에 따른 특성을 측정, 분석하여 최적의 접지면 크기를 산출하였다. 폴디드 안테나의 특성에 미치는 접지면 효과를 알아보기 위해 동박판을 잘라 기존의 폴디드 슬롯 안테나의 접지면을 확장시켰을 때 임피던스 및 방사 특성의 변화를 조사한 결과 임피던스 특성에는 별로 영향을 주지 않았으나, 방사 특성에는 많은 영향을 미치고 있음을 확인 할 수 있었다. 접지면의 크기를 고려한 엄격한 설계를 위해서는 복잡한 과정을 거쳐야 하지만, 접지면의 효과를 무시할 수 있는 적당한 크기를 산정하여 제작한다면 좀더 간단하게 안테나를 제작할 수 있을 것이다.

  • PDF

개별 부하모델링을 위한 부하의 합리적인 특성실험 (Reasonable Load Characteristic Experiment for Component Load Modeling)

  • 지평식;이종필;임재윤;추진부;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.45-52
    • /
    • 2002
  • Load modeling is classified into two methods according to approaching method, so called the measurement and component-based method. The measurement method is to model the load characteristics measured directly at substations and feeders. But it is difficult to measure continuously load characteristics from naturally occurring. system variation. The component-based method consists of the fellowing process; component load modeling, composition rate estimation and aggregation of component loads, etc. In this paper, the characteristic experiment of component loads was performed to obtain data for the component load modeling as the component-based method. At first, representative component loads were selected by the proposed method considering the accuracy of load modeling and the performance possibility of component load experiment in the laboratory. Also an algorithm was Proposed to identify the reliability of data obtained from the component load characteristic experiments. In addition, the results were presented as the case studies.

다실린더기관 흡기관내의 압력변동과 체적효율에 관한 연구 (A Study on the Pressure Variation of Intake Pipe and the Volumetric Efficiency in a Multi-Cylinder Engine)

  • 서정일;조진호;김형섭;김병주
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.179-188
    • /
    • 1990
  • 본 연구에서는 4사이클, 4실린더기관을 대상으로 하고 흡배기계의 유동특성에 관계되는 인자들을 고려하여 가스교환 과정 시뮬레이션과 실험을 수행하였다. 관내 의 유동현상의 해석에는 압력, 속도의 변화에 대하여 추종성이 좋은 특성곡선법을 이 용하였으며 실험에 있어서 흡기관내의 압력은 직접 제작한 데이터처리장치를, 실린더 내의 압력은 연소압력계측장치를 이용하여 측정하였다. 연구의 목적은 시뮬레이션에 의하여 흡기관내의 압력변동 및 체적효율을 계산한 결과와 실험결과를 비교검토함으로 서 특성곡선법에 의한 본 해석결과의 타당성과 실제기관에의 적용성을 확인하고 흡배 기계의 형상과 치수, 흡배기밸브의 개폐시기, 압축비 등과 체적효율 및 관내의 압력변 동과의 관계를 구명하여 흡기관의 동적효과를 이용할 수 있는 흡기계의 최적설계 및 개선을 위한 자료를 얻고자 한다.

The Characteristic Modes and Structures of Bluff-Body Stabilized Flames in Supersonic Coflow Air

  • Kim, Ji-Ho;Yoon, Young-Bin;Park, Chul-Woung;Hahn, Jae-Won
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권3호
    • /
    • pp.386-397
    • /
    • 2012
  • The stability and structure of bluff-body stabilized hydrogen flames were investigated numerically and experimentally. The velocity of coflowing air was varied from subsonic velocity to a supersonic velocity of Mach 1.8. OH PLIF images and Schlieren images were used for analysis. Flame regimes were used to classify the characteristic flame modes according to the variation of the fuel-air velocity ratio, into jet-like flame, central-jet-dominated flame, and recirculation zone flame. Stability curves were drawn to find the blowout regimes and to show the improvement in flame stability with increasing lip thickness of the fuel tube, which acts as a bluff-body. These curves collapse to a single line when the blowout curves are normalized by the size of the bluff-body. The variation of flame length with the increase in air flow rate was also investigated. In the subsonic coflow condition, the flame length decreased significantly, but in the supersonic coflow condition, the flame length increased slowly and finally reached a near-constant value. This phenomenon is attributed to the air-entrainment of subsonic flow and the compressibility effect of supersonic flow. The closed-tip recirculation zone flames in supersonic coflow had a reacting core in the partially premixed zone, where the fuel jet lost its momentum due to the high-pressure zone and followed the recirculation zone; this behavior resulted in the long characteristic time for the fuel-air mixing.

분사기 배열과 추진제 유량 변화에 의한 축소형 연소기의 연소특성 (Combustion Characteristics of Sub-scale Combustors on the variation of propellant mass flow and injector arrangement)

  • 이광진;서성현;김성구;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.168-172
    • /
    • 2008
  • 추진제 유량 변화와 분사기 배열에 따른 특성속도를 연구하기 위해 축소형 연소기를 이용하여 연소시험을 수행하였다. 그 결과 유사한 압력과 혼합비 조건에서 효과적인 비 단위 면적당 유량 범위가 존재함을 알 수 있었고 최외곽 분사기로부터 막 냉각이 적용된 연소실 벽면까지의 거리 증가는 연소실 내 저 혼합비 영역을 증가시키고 특성속도를 저감시키는 기능을 하는 것으로 해석결과 나타났다. 즉, 이 2가지 설계요소는 주어진 연소압력에서 액체로켓엔진 연소기의 성능을 향상시킬 수 있는 중요한 인자임을 확인하였다.

  • PDF

Lamb skin 코팅용 polyether polyol을 이용한 hard segment를 형성하는 polyurethane compound의 합성 및 물성에 관한 연구 (A study on properties and synthesis of polyurethane compound formed hard segments by polyether polyol for lamb skin coat)

  • 이주엽;남상성
    • 한국응용과학기술학회지
    • /
    • 제31권2호
    • /
    • pp.296-304
    • /
    • 2014
  • 본 연구에서는 hard segment를 형성하고 있는 폴리우레탄을 합성한 다음 피혁산업에서 마감 코팅시 많이 사용되고있는 폴리에틸렌왁스의 적하량을 점차 증가시켜 필름 및 Lam skin에 코팅에 적용하여 변화하는 물성을 측정하였다. 내용제성 측정 결과 높은 내용제성 물성을 지닌 폴리우레탄 수지에 폴리에틸렌왁스의 함량에 따른 물성적 변화는 크게 나타나지 않았다. 인장 강도 측정치에서는 폴리우레탄 단독 필름의 측정치가 $1.235kg_f/mm^2$로 가장 높은 수치를 나타내었으며, 폴리에틸렌왁스의 함량이 제일 높은 PUD-EW3가 가장 낮은 인장력 $1.022kg_f/mm^2$를 나타내었다. 또한 내마모도 측정에서는 PUD가 제일 높은 52.22 5mg.loss로 우수한 물성변화를 나타내었고, 연실율의 경우 역시 우레탄 단독 코팅인 PUD가 698%로 가장 높은 수치를 나타내었다.

브랜치라인 커플러 결합을 이용한 가변 전력 분배기 회로 (A variable power divider circuit using the combine characteristic of the branchline coupler)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.245-251
    • /
    • 2017
  • 제안된 가변 전력 분배기는 입력된 신호를 동일한 신호 전력으로 분배하는 2-way 윌킨슨 전력 분배기, 90도 위상변화가 가능한 두 개의 가변 위상 변환기, 두 개의 경로 신호를 결합하는 브랜치라인 커플러로 구성된다. 제안된 가변전력 분배기는 이론적으로 가변 위상 변환기의 90도 위상 변화에 의해 브랜치라인 커플러의 두 개 출력 단자에 ${\infty}:1$에서 ${\infty}:1$까지 전력 분배 비율로 출력할 수 있다. 제안된 가변 전력 분배기는 중심주파수 1.7 GHz에서 Taconic사의 TLX-9 20mil을 이용하여 제작해 동작 특성을 확인하였다. 제작된 회로는 1.7 GHz에서 두 개 출력 단자에 1:100에서부터 200:1까지 전력 분배 비율의 변화가 가능하였으며, 1.65-1.75 GHz 주파수 대역에서 다양한 전력 분배 비율에 대하여 입력 반사계수 약 -16 dB 이하, 삽입 손실 약 -1.0 dB, 두 출력 단자의 격리 특성 약 -17 dB 이하의 안정적인 특성을 보였다.

CIP 부피비에 따른 이방성 MRE의 전단계수 변화율 (The Variation Rate of Shear Modulus for Anisotropic Magneto-rheological Elastomer due to Volume Fraction of CIP)

  • 정운창;윤지현;양인형;이유엽;오재응
    • 한국소음진동공학회논문집
    • /
    • 제21권12호
    • /
    • pp.1132-1137
    • /
    • 2011
  • MRE(magneto-rheological elastomers) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb vibration of broader frequency range. These characteristic phenomena result from the orientation of magnetic particles named carbonyl iron powder(CIP) in rubber matrix. In this paper, simulation on variation rate of shear modulus for anisotropic MRE due to volume fraction of CIP and an effective permeability model was applied to predict the field-induced shear modulus of MREs. Also, the variation rate of shear modulus for anisotropic MRE was derived using magneto-mechanical theory. Based on Maxwell-Garnett mixing rule, the increment of shear modulus was calculated to evaluate the shear modulus of MREs with column structure of CIP due to induced current. The simulation results on variation rate of shear modulus can be applied to the variable mechanical system of MRE such as tunable vibration absorber, stiffness variable bush and mount.

주파수 변동시 불평형 전압에 강인한 DSC-PLL 설계 연구 (The Design of Robust DSC-PLL under Distorted Grid Voltage Contained Unbalance on Frequency Variation)

  • 이재도;차한주
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1447-1454
    • /
    • 2018
  • In this paper, the design of robust DSC-PLL(Delayed Signal Cancellation Phase Locked Loop) is proposed for coping with frequency variation. This method shows significant performance for detection of fundamental positive sequence component voltage when the grid voltage is polluted by grid unbalance and frequency variation. The feedback frequency estimation of DSC-PLL is tracking the drift in the phase by unbalance and frequency variation. The robust DSC PLL is to present the analysis on method and performance under frequency variations. These compensation algorithms can correct for discrepancies of changing the frequency within maximum 193[ms] and improve traditional DSC-PLL. Linear interpolation method is adopted to reduce the discretized errors in the digital implementation of the PLL. For verification of robust characteristic, PLL methods are implemented on FPGA with a discrete fixed point based. The proposed method is validated by both Matlab/Simulink and experimental results based on FPGA(XC7Z030).