• 제목/요약/키워드: Characteristic impedance

검색결과 608건 처리시간 0.028초

Compact Branch-line Power Divider Using Connected Coupled-line Structure

  • Yun, Tae-Soon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.109-114
    • /
    • 2018
  • In order to improve performance for the size of the BLPD, the CCL is used for the realization as the delay line. As realizing lower coupling coefficient and lower characteristic impedance, the CCL has good performance of the phase delay. The CCL is applied as the compact BLPD with optimized coupling factor and matched impedance because the lower coupling coefficient and lower characteristic impedance are increased the size and the loss, respectively. Designed BLPD using the CCL has the size of $0.13{\lambda}_g{\times}0.13{\lambda}_g$ and the size-reduction ratio of fabricated BLPD using the CCL has 58.5% ($21.08{\times}21.40mm^2$). Also, fabricated BLPD is measured the insertion loss of 3.16dB at the center frequency of 1.78GHz and the 20dB bandwidth is 9.58%. Differenced magnitude and phase between threw port and coupled port are measured 0.1dB and $89.9^{\circ}$, respectively. These performances are almost same compared with the conventional BLPD. Suggested application of the CCL can be used various devices and circuits for the size-reduction.

뇌격전류 측정의 정확도에 영향을 미치는 요인 (Factors Affected the Accuracy of Lightning Current Measuring System)

  • 이복희;장근철;강성만;엄주홍;정길조;심응보;우정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF

고전압 임펄스궤도회로의 동작특성 연구 (Study on the Operating Characteristics of High Voltage Impulse Track Circuit)

  • 이태훈;박기범;전용주;류영태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1279-1284
    • /
    • 2008
  • This paper presents the operating characteristic of high voltage impulse(HVI) track circuit owing to the ill-contact of impedance bond lead wire. The characteristic operations of the track include rail voltage and current. Measurements are carried out using oscilloscope with current probe and it analyzed the abnormal operation due to connector of protective wire. Finally, suitable track circuit is proposed for conventional line, and operating characteristic of HVI track circuit is affected by bypass circuit.

  • PDF

λ/4 전송 선로와 π-네트워크를 이용한 UHF-대역 적응형 임피던스 정합 회로 설계 (A Design of Adaptive Impedance Tuning Circuit for UHF-Band Using λ/4 Transmission Line and π-Network)

  • 황수설;홍성용
    • 한국전자파학회논문지
    • /
    • 제23권3호
    • /
    • pp.367-376
    • /
    • 2012
  • 본 논문에서는 물리적인 환경 변화에 의해 발생될 수 있는 갑작스런 부하단 임피던스의 변화에 능동적으로 대응할 수 있는 적응형 임피던스 정합 회로를 구성하는 부정합 측정부, 임피던스 정합부, 조정 알고리즘부의 특성과 현재까지 진행된 연구 수준을 확인해 보았고, ${\lambda}/4$ 전송 선로와 ${\pi}$-네트워크를 이용하여 간단히 구성된 적응형 임피던스 정합 회로의 설계 결과를 보였다. 이를 위해 간단한 구성을 가지면서 반복적인 계산없이 임의의 부하단 임피던스를 바로 제어할 수 있는 적응형 임피던스 정합 회로를 제안하였고, 설계를 위한 계산식을 유도하였다. 또한, 유도된 계산식을 통해 최적화된 임피던스를 찾아주어 능동적으로 제어할 수 있는 조정 알고리즘도 제시하였다. 제안한 적응형 임피던스 정합 회로에서 유도된 계산식과 조정 알고리즘을 이용하여 시뮬레이션을 수행하였고, 시뮬레이션 결과 임의의 부하단 임피던스가 회로에 최적화된 임피던스로 능동적으로 제어 될 수 있음을 확인하였다.

옥내 전력선 통신 채널 임피던스 특성 측정 (Measurement of Channel Impedance Characteristics for Indoor Power Line Communications)

  • 허윤석;김철;홍봉화;이대영;전계석
    • 대한전자공학회논문지TC
    • /
    • 제42권11호
    • /
    • pp.79-86
    • /
    • 2005
  • 본 논문에서는 정상적으로 전기가 공급되고 있는 전력선상에서 주파수의 함수로 표현되는 임피던스 측정 방법을 기술한다. 측정방법으로 전력선 통신사용 주파수 $30Khz\~1Mhz$ 대역의 미소 신호를 연속적으로 전력선에 주입하고, 구현한 임피던스 측정 장치는 측정된 전압과 전류의 크기와 위상으로부터 옥내 채널 임피던스를 계산한다. 임피던스 측정에 있어 광대역 주파수 범위의 임피던스 대 주파수 특성을 수행한다. 구현된 임피던스 측정 장치는 옥내에서 발생하는 부하에 의해 변화하는 전력선 임피던스를 측정하여 전력선 통신 환경을 분석할 수 있는 장비이다. 측정된 데이터는 데이터베이스화 하여 전력선 통신 모뎀의 통신성능 평가 및 테스트 환경 기준 설정에 유용하게 사용될 수 있을 것이다.

Ti:$LiNbO_3$ 진행파 광변조기의 FEM 전극해석 및 대역폭 예측 (FEM analysis of Ti:$LiNbO_3$ optical modulator's traveling-wave electrodes and estimation of modulation band-width)

  • 김창민;한상필
    • 전자공학회논문지A
    • /
    • 제32A권2호
    • /
    • pp.96-110
    • /
    • 1995
  • Traveling-wave electrodes for the high-speed Ti:LiNbO$_{3}$ modulators are designed. For a solution to the problems of 1) phase-velocity mismatching between the optical wave and the Modulating M/W, 2) M/W electrode characteristic impedance mismateching, we assume devices with 1$\mu$m thick SiO$_{2}$ buffer layer between the electrode and the Ti:LiNbO$_{3}$ substrate. The electrode analyses are performed by the FEM using the second-order triangular elements. The optimum design parameters to satisfy the phase-velocity matching and the characteristic impedance matching are sought for. By use of the analyses' results, a Mach-Zehnder optical modulator with a CPW electrode is designed as an example. the band-width estimation is also illustrated.

  • PDF

초전도 케이블의 퀜치 특성에 대한 계통안전성 제어방식 (Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable)

  • 이근준;황시돌;이정필;김창현;박희철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2004
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, and HTS cable could be one of the countermeasure to solve the transfer limit as its higher current capacity and lower impedance[1]. However, the quench characteristic of HTS cable makes HTS cable to loss its superconductivity, and therefore change the impedance of the line and power system operating condition dramatically. This pheonominum threats not only HTS cable safety but also power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method by FCL(Fault Current Limiter) was suggested.

  • PDF

정합회로 설계를 위한 초음파 진동자 Modeling S/W Tool 구현 (Ultrasonic Sensor Modeling S/W Tool for matching circuit design)

  • 편용국
    • 한국컴퓨터산업학회논문지
    • /
    • 제5권1호
    • /
    • pp.177-182
    • /
    • 2004
  • 소나 센서부 설계 시 개별 센서에 대한 정합회로의 설계는 전체 가중회로의 특성에 매우 큰 영향을 미친다. 그러나 많은 경우 정합회로를 설계하는데 있어서 경험에 의한 수작업으로 수행하거나 매우 간단한 모델을 설정하여 그것을 바탕으로 설계하는 예가 많다. 다양한 센서에 대해서 유연하게 대응하는데 한계를 갖고 있고 또 많은 오류를 동반하기 때문에 정합회로 설계에 많은 시행착오를 초래한다. 본 연구에서는 다양한 센서에 유연하게 대응하는 정합회로 설계 도구를 구성하는 첫 단계로써 실제 소나 센서의 특성 측정 및 그를 바탕으로 한 소자 모델링을 일괄 작업화한 설계 프로그램을 구성하여, 그 구성과 기능에 대해서 설명하고자 한다.

  • PDF

고온 초전도 전력 케이블의 고장전류 특성 해석 (Fault current characteristic analysis of HTS power cable)

  • 김진근;이재득;김재호;김아롱;조전욱;심기덕;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.629-630
    • /
    • 2008
  • Before applying the HTS power cable to the real utility, the system needs to be analyzed using certain simulation tools. The impedance of superconductor is changed due to the magnitude of current, temperature, and magnetic field. PSCAD/EMTDC does not provide the superconductor component which has the impedance characteristic. The authors have developed the HTS power cable component in EMTDC program which included the same electrical characteristics as real HTS power cable previously. Based on the research results, the authors analyzed fault current characteristics of HTS power cable using the developed EMTDC model component.

  • PDF

전송선 이론에 의한 적외선 흡수 구조체의 흡수율 모의시험 (Modeling and simulation on an IR absorbing structure with the cascaded transmission line model)

  • 박승만
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1725-1729
    • /
    • 2013
  • In this paper, the modeling and simulation of infrared absorption in an infrared absorbing structure with the cascaded transmission line model were carried out. Each layer in the infrared absorbing structure can be modeled as a characteristic impedance of the cascaded transmission line model. The simulation results show that the cavity thickness to get a maximum absorption should be less than a quarter wavelength, which is somewhat different from prevalent thickness. It can be assured that the sheet resistance of an absorbing layer to get a maximum absorption is $377{\Omega}/{\square}$, that the thickness of the absorbing layer dose not affect the spectral characteristics of absorption. It is also shown that the thickness of the active layer is not critical to the IR absorption. It can also be assured that the validation of this modeling is proved in comparison with the previous results from similar absorbing structures.