• Title/Summary/Keyword: Channel uncertainty

Search Result 116, Processing Time 0.025 seconds

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

Beamforming Optimization for Multiuser Two-Tier Networks

  • Jeong, Young-Min;Quek, Tony Q.S.;Shin, Hyun-Dong
    • Journal of Communications and Networks
    • /
    • v.13 no.4
    • /
    • pp.327-338
    • /
    • 2011
  • With the incitation to reduce power consumption and the aggressive reuse of spectral resources, there is an inevitable trend towards the deployment of small-cell networks by decomposing a traditional single-tier network into a multi-tier network with very high throughput per network area. However, this cell size reduction increases the complexity of network operation and the severity of cross-tier interference. In this paper, we consider a downlink two-tier network comprising of a multiple-antenna macrocell base station and a single femtocell access point, each serving multiples users with a single antenna. In this scenario, we treat the following beamforming optimization problems: i) Total transmit power minimization problem; ii) mean-square error balancing problem; and iii) interference power minimization problem. In the presence of perfect channel state information (CSI), we formulate the optimization algorithms in a centralized manner and determine the optimal beamformers using standard convex optimization techniques. In addition, we propose semi-decentralized algorithms to overcome the drawback of centralized design by introducing the signal-to-leakage plus noise ratio criteria. Taking into account imperfect CSI for both centralized and semi-decentralized approaches, we also propose robust algorithms tailored by the worst-case design to mitigate the effect of channel uncertainty. Finally, numerical results are presented to validate our proposed algorithms.

The analysis Influencing Mobile Channel Loyalty using a Transaction Cost Theory (거래비용이론을 이용한 모바일 채널충성도에 미치는 영향 분석)

  • Jang, Sung-Hee;Jung, Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.10
    • /
    • pp.149-157
    • /
    • 2009
  • This study aims to empirically examine the factors influencing mobile channel loyalty. This study has been reviewed various theoretical research relating to mobile channel loyalty and transaction cost theory. The model was tested Structural Equation Modeling(SEM) using AMOS 7.0 analysis on the sample collected from 240 respondents. The result of hypothesis testing is as follows. First, asset specificity, uncertainty and transaction frequency were influenced by chanel satisfaction. Second, asset specificity was influenced negatively by chanel preference. Third, chanel satisfaction was influenced positively by chanel preference. Finally, chanel satisfaction and chanel preference were influenced positively by chanel loyalty.

A $0.18{\mu}m$ CMOS 3.2-Gb/s 4-PAM Serial Link Receiver Using Current Mode Signaling (Current Mode Signaling 방법을 이용한 $0.18{\mu}m$ CMOS 3.2-Gb/s 4-PAM Serial Link Receiver)

  • Lee, Jeong-Jun;Jeong, Ji-Kyung;Burm, Jin-Wook;Jeong, Young-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.79-85
    • /
    • 2009
  • The design of a 3.2 Gb/s serial link receiver in $0.18{\mu}m$ CMOS process is presented. The major factors limiting the performance of high-speed links are transmission channel bandwidth, timing uncertainty. The design uses a multi-level signaling(4-PAM) to overcome these problems. Moreover, to increase data bit-rate and lower BER, we designed this circuit by using a current mode amplifier, Current-mode Logic(CML) sampling latches. The 4-PAM receiver achieves 3.2 Gb/s and BER is less than $1.0\;{\times}\;10^{-12}$. The $0.5\;{\times}\;0.6\;mm^2$ chip consumes 49 mA at 3.2 Gb/s from a 1.8-V supply.

Construction Broadband CARS Spectrometer and Uncertainty Analysis of Temperature Measurement (광대역 CARS 분광기의 제작과 온도 측정의 정확도 분석)

  • 박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.226-232
    • /
    • 1993
  • A broadband CARS system is constructed for shot by shot measurement of a full CARS spectrum, which consists of a frequency doubled Nd:Yag laser, broadband mode-less laser and optical multi-channel analyzer installed in a double grating monochromator. To increase the accuracy of CARS temperature measurement and get better the fitting goodness, we have measured the slit function of the detection system and determined the analytical functional form of the slit function. Accuracy of the CARS system for temperature measurement is evaluated from the difference between the best-fit temperature of CARS spectrum and temperature of thermocouple reading. The uncertainty of the temperature measurement is found to be less than 1.5% in temperature range from 300 K to 1300 K.

  • PDF

Model Matching for Composite Asynchronous Sequential Machines in Cascade Connection (직렬 결합된 복합 비동기 순차 머신을 위한 모델 정합)

  • Yang, Jung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.253-261
    • /
    • 2013
  • In this paper, we study the problem of controlling composite asynchronous sequential machines. The considered asynchronous machine consists of two input/state machines in cascade connection, where the output of the front machine is delivered to the input channel of the rear machine. The objective is to design a corrective controller realizing model matching such that the stable state behavior of the closed-loop system matches that of a reference model. Since the controller receives the state feedback of the rear machine only, there exists uncertainty about the present state of the front machine. We specify the existence condition for a corrective controller given the uncertainty. The design procedure for the proposed controller is described in a case study.

On Robust MMSE-Based Filter Designs for Multi-User Peer-to-Peer Amplify-and-Forward Relay Systems (증폭 및 전달 릴레이 기반 다중 사용자 피어투피어 통신 시스템에서 강인한 MMSE 필터 설계 방법)

  • Shin, Joonwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.9
    • /
    • pp.798-809
    • /
    • 2013
  • In this paper, we propose robust relay and destination filter design methods for the multi-user peer-to-peer amplify-and-forward relaying systems while taking imperfect channel knowledge into consideration. Specifically, the relay and destination filter sets are developed to minimize the sum mean-squared-error (MSE). We first present a robust joint optimum relay and destination filter calculation method with an iterative algorithm. Motivated by the need to reduce computational complexity of the iterative scheme, we then formulate a simplified sum MSE minimization problem using the relay filter decomposability, which lead to two robust sub-optimum non-iterative design methods. Finally, we propose robust modified destination filter design methods which require only local channel state information between relay node and a specific destination node. The analysis and simulation results verify that, compared with the optimum iterative method, the proposed non-iterative schemes suffer a marginal loss in performance while enjoying significantly improved implementation efficiencies. Also it is confirmed that the proposed robust filter design methods provide desired robustness in the presence of channel uncertainty.

The Influence of Transaction Cost Approach Factor on Channel Loyalty (거래비용접근방법 불확실성요인과 거래관계성이 채널 충성도에 미치는 영향에 관한 연구)

  • Lee, Ji-eun
    • Management & Information Systems Review
    • /
    • v.33 no.2
    • /
    • pp.281-299
    • /
    • 2014
  • This study using a transaction cost approach perspective, this paper presents a model for understanding shopper's buying behavior. Finally, based on the results of these studies, this paper suggests practical implications to companies establishing their management strategy of the channels. In order to achieve the research purpose, it derived hypotheses from the literature studies and conducted questionnaire survey for the buyer who actually purchased by distribution channels. In this paper, 876 of the samples has been used in practice and with those samples it analyzes its empirical testing through reliability verification, validation, factor analysis, correlation analysis and covariance structure analysis.

  • PDF

Application of Micro-Thin Laser sheet and Mixed Solvent for Micro-LIF Measurement in a Microchannel (마이크로 채널 내부의 Micro-LIF 측정을 위한 마이크로 레이저 평면빔과 혼합용매의 적용)

  • Yoon Sang Youl;Kim Jae Min;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.86-89
    • /
    • 2004
  • One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1$ to 3(3 or 5(5 pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

Hydrazine Doped Graphene and Its Stability

  • Song, MinHo;Shin, Somyeong;Kim, Taekwang;Du, Hyewon;Koo, Hyungjun;Kim, Nayoung;Lee, Eunkyu;Cho, Seungmin;Seo, Sunae
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.192-199
    • /
    • 2014
  • The electronic property of graphene was investigated by hydrazine treatment. Hydrazine ($N_2H_4$) highly increases electron concentrations and up-shifts Fermi level of graphene based on significant shift of Dirac point to the negative gate voltage. We have observed contact resistance and channel length dependent mobility of graphene in the back-gated device after hydrazine monohydrate treatment and continuously monitored electrical characteristics under Nitrogen or air exposure. The contact resistance increases with hydrazine-treated and subsequent Nitrogen-exposed devices and reduces down in successive Air-exposed device to the similar level of pristine one. The channel conductance curve as a function of gate voltage in hole conduction regime keeps analogous value and shape even after Nitrogen/Air exposure specially whereas, in electron conduction regime change rate of conductance along with the level of conductance with gate voltage are decreased. Hydrazine could be utilized as the highly effective donor without degradation of mobility but the stability issue to be solved for future application.