• Title/Summary/Keyword: Channel Width

Search Result 808, Processing Time 0.027 seconds

High resolution flexible e-paper driven by printed OTFT

  • Hu, Tarng-Shiang;Wang, Yi-Kai;Peng, Yu-Rung;Yang, Tsung-Hua;Chiang, Ko-Yu;Lo, Po-Yuan;Chang, Chih-Hao;Hsu, Hsin-Yun;Chou, Chun-Cheng;Hsieh, Yen-Min;Liu, Chueh-Wen;Hu, Jupiter
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.421-427
    • /
    • 2009
  • We successfully fabricated 4.7-inch organic thin film transistors array with $640{\times}480$ pixels on flexible substrate. All the processes were done by photolithography, spin coating and ink-jet printing. The OTFT-Electrophoretic (EP) pixel structure, based on a top gate OTFT, was fabricated. The mobility, ON/OFF ratio, subthreshold swing and threshold voltage of OTFT on flexible substrate are: 0.01 ^2/V-s, 1.3 V/dec, 10E5 and -3.5 V. After laminated the EP media on OTFT array, a panel of 4.7-inch $640{\times}480$ OTFT-EPD was fabricated. All of process temperature in OTFT-EPD is lower than $150^{\circ}C$. The pixel size in our panel is $150{\mu}m{\times}150{\mu}m$, and the aperture ratio is 50 %. The OTFT channel length and width is 20 um and 200um, respectively. We also used OTFT to drive EP media successfully. The operation voltages that are used on the gate bias are -30 V during the row data selection and the gate bias are 0 V during the row data hold time. The data voltages that are used on the source bias are -20 V, 0 V, and 20 V during display media operation.

  • PDF

CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module (공기식 태양광/열 시스템 공기채널 내 여러 저항체 설치에 따른 전열성능에 관한 CFD 해석)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Kim, Young-Bok;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.33-43
    • /
    • 2018
  • PV/Thermal module is the combined system, which consist of a photovoltaic module and solar thermal collector that can obtain electrical power and thermal energy simultaneously. Thus the power generation can be increase by decreasing the temperature of photovoltaic module and thermal energy retrieved from module also can be used for heating system. In this study, Heat transfer performance of air type PV/Thermal module was confirmed with various bottom obstacles that can be installed easily to real photovoltaic module by CFD (computational fluid dynamics) analysis. Eight type obstacles were investigated according to the shape and arrangement. As a result, nusselt number represent heat transfer performance was increased about 86% compare with the basic type PV/Tthermal module that has no obstacle and triangle type obstacle had higher value than other types. But pressure drop was also increased with increment of heat transfer enhancement. Thus the performance factor considering both heat transfer and pressure drop was confirmed and V-fin type obstacle arranged in a row for Reynolds number below 9,600 and protrusion type obstacle arranged in zigzag for Reynolds number above 14,400 were shown higher performance factor than other types. From these results, V-fin type obstacle arranged in row and protrusion type obstacle arranged in zigzag were considered as a proper type for applying to real PV/thermal module according to operating condition. But the heat transfer performance can be changed by the geometric conditions of obstacle such as height, width, length and arrangement. Thus, it could also confirmed that the optimal condition and arrangement of this obstacle need to be found in further study.

Experimental Investigation on the Droplet Entrainment in the Air-Water Horizontal Stratified Flow (물-공기 수평 성층류 유동조건에서 액적이탈 현상에 대한 실험연구)

  • Bae, Byeong Geon;Yun, Byong Jo;Kim, Kyoung Doo;Bae, Byoung Uhn
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.114-122
    • /
    • 2015
  • In the high convective gas flow condition, irregular shaped water waves from which droplet entrainment occurs are generated under horizontally stratified two-phase flow condition. KAERI proposed a new mechanistic droplet entrainment model based on the momentum balance equation consisting of the shear stress, surface tension, and gravity forces. However, this model requires correlation or experimental data of several physical parameters related to the wave characteristics. In the present study, we tried to measure the physical parameters such as wave slope, wave hypotenuse length, wave velocity, wave frequency, and wavelength experimentally. For this, an experiment was conducted in the horizontal rectangular channel of which width, height, and length are, respectively, 40 mm, 50 mm, and 4.2 m. In the present test, the working fluids are chosen as air and water. The PIV technique was applied not only to obtain images for phase interface waves but also to measure the velocity field of the water flow. Additionally, we developed the parallel wire conductance probe for the confirmation of wave height from PIV image. Finally, we measured the physical parameters to be used in the validation of new droplet entrainment model.

Numerical study on flow characteristics at dividing open-channel with changing bifurcation angle using TELEMAC-2D (TELEMAC-2D모형을 이용한 분류각 변화에 따른 개수로 흐름특성변화 수치모의 연구)

  • Jung, Daejin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.617-626
    • /
    • 2020
  • This study investigates changes of bifurcation discharge ratio, flow velocity distributions and characteristics of separation zone due to variation of bifurcation angle by using TELEMAC-2D model. When the bifurcation angle is reduced from 90° to 45° without changing the boundary conditions, the bifurcation discharge ratio increased by 1.5 times from 0.523 to 0.785 because of increasing the radius of curvatures, the inertia force of the downstream flow, and the pressure gradient by the downstream boundary conditions. The bifurcation discharge ratio increases non-linearly whenever the bifurcation angle decreases by 15° intervals from 90° to 45° in flow with the upstream Froude number of 0.45 to 0.74. In flow with a maximum Froude number of 0.74, the rate of increase for bifurcation discharge ratio is 31.1% and the minimum value. When the Froude number is 0.58, the bifurcation discharge ratio is 0.7 or less, and the maximum rate of increase for that ratio is 53.5%. As the upstream Froude number decreases less than 0.58, the bifurcation discharge ratio exceeds 0.7, and the rate of increase decreases. When the upstream Froude number is 0.4 higher, the dimensionless width and length changing ratio of the separation zone are about 2.56 and 5.5 times higher than in 0.4 or less.

Study on the Effect of Product Line Pricing on Loading Efficiency and Logistics Cost (상품라인별 가격결정이 적재효율 및 물류비에 미치는 영향에 관한 연구)

  • Jung, Sung-Tae;Yoon, Nam-Soo;Han, Kyu-Chul
    • Journal of Distribution Science
    • /
    • v.12 no.8
    • /
    • pp.55-69
    • /
    • 2014
  • Purpose - Despite the importance of price, many companies do not implement pricing policies smoothly, because typical price management strategies insufficiently consider logistics efficiency and an increase in logistics costs due to logistics waste. This study attempts to examine the effect of product line pricing, which corresponds to product mix pricing, on logistics efficiency in the case of manufacturer A, and analyzes how logistics performance changes in response to these variables. Research design, data, and methodology - This study, based on the case of manufacturer A, involved research through understanding the current status, analyses, and then proposing improvement measures. Among all the products of manufacturer A, product group B was selected as the research object, and its distribution channel and line pricing were examined. As a result of simulation, for products with low loading efficiency, improvement measures such as changing the number of bags in the box were suggested, and a quantitative analysis was conducted on how these measures influence logistics costs. The TOPS program was used for the Pallet loading efficiency simulation tool in this study. To prevent products from protruding out of the pallet, the maximum measurement was set as 0.0mm, and loading efficiency was based on the pallet area, and not volume. In other words, its size (length x width) was focused upon, following the purpose of this study and, then, the results were obtained. Results - As a result of the loading efficiency simulation, when the number of bags in the box was changed for 36 products with low average loading efficiency of 73.7%, as shown in

    , loading efficiency improved to 89.9%. Further, from calculating logistics cost based on the cost calculation standard of manufacturer A, the amount of annual logistics cost reduction amounted to 101,458,084 KRW. Given that the sum of the logistics cost of the product group B of manufacturing enterprises A is 400,340,850 KRW, it can be reduced by 25%, to 298,882,766 KRW. Although many methods improve loading efficiency, this study proved that logistics cost could be reduced by changing the number of bags within boxes. If this measure is applied to other items, visible logistics cost reduction effects will be realized through improvements in loading efficiency. Conclusions - Future pricing policies should consider their correlation with quality, loading efficiency, product specifications, and logistics standardization to prevent logistics waste, enabling management to improve earnings for companies. Thus, when companies decide pricing policies for new products, the aspects of merchandising and marketing should take priority; however, the aspect of logistics also needs to be considered as significant. Measures revealed by the study results are not only the responsibilities of manufacturing enterprises. Pricing policy agreements between manufacturing enterprises and distribution companies, and logistics factors related to price determination should be considered; further, governments should also support them for their collaborations. This will enable consumers to purchase quality products with low prices.

  • Effect on the Wake Flow according to Various length of Rectangular Cylinder in a Parallel Arrangement (병렬구조를 가진 장방형 실린더의 길이가 후류 유동에 미치는 영향)

    • Choe, Sang-Bom;Cho, Dae-Hwan
      • Journal of the Korean Society of Marine Environment & Safety
      • /
      • v.20 no.6
      • /
      • pp.760-767
      • /
      • 2014
    • An experimental study is carried out to investigate the effect of jet stream in the gab of rectangular cylinders with different length in a parallel arrangement by using PIV method in a circulating water channel. The height(h) of the rectangular cylinder and the gap between the cylinder is 10mm, and the width(B) which is 300mm. The length of the model for flow direction was applied to 30mm, 60mm, 90mm & 120mm, The aspect ratio of a model on the basis of height(H=30mm) is 1, 2, 3 and 4. Reynolds number $Re=1.4{\times}10^4$, $Re=2.0{\times}10^4$, $Re=2.9{\times}10^4$ based on the height(H) of model for the distance of tidal distributions as of water depth have been applied during the whole experiments. The measurement area was set to 5H rear of the cylinder. As a result, Vortex size in the wake area were increased as velocity increased. and high aspect ratio increased through-flow velocity component in the near wake. Velocity deficit increased highly after near-wake area and low aspect ratio.

    SPA-Resistant Unsigned Left-to-Right Receding Method (SPA에 안전한 Unsigned Left-to-Right 리코딩 방법)

    • Kim, Sung-Kyoung;Kim, Ho-Won;Chung, Kyo-Il;Lim, Jong-In;Han, Dong-Guk
      • Journal of the Korea Institute of Information Security & Cryptology
      • /
      • v.17 no.1
      • /
      • pp.21-32
      • /
      • 2007
    • Vuillaume-Okeya presented unsigned receding methods for protecting modular exponentiations against side channel attacks, which are suitable for tamper-resistant implementations of RSA or DSA which does not benefit from cheap inversions. The proposed method was using a signed representation with digits set ${1,2,{\cdots},2^{\omega}-1}$, where 0 is absent. This receding method was designed to be computed only from the right-to-left, i.e., it is necessary to finish the receding and to store the receded string before starting the left-to-right evaluation stage. This paper describes new receding methods for producing SPA-resistant unsigned representations which are scanned from left to right contrary to the previous ones. Our contributions are as follows; (1) SPA-resistant unsigned left-to-right receding with general width-${\omega}$, (2) special case when ${\omega}=1$, i.e., unsigned binary representation using the digit set {1,2}, (3) SPA-resistant unsigned left-to-right Comb receding, (4) extension to unsigned radix-${\gamma}$ left-to-right receding secure against SPA. Hence, these left-to-right methods are suitable for implementing on memory limited devices such as smartcards and sensor nodes

    Modeling 2D residence time distributions of pollutants in natural rivers using RAMS+ (RAMS+를 이용한 하천에서 오염물질의 2차원 체류시간 분포 모델링)

    • Kim, Jun Song;Seo, Il Won;Shin, Jaehyun;Jung, Sung Hyun;Yun, Se Hun
      • Journal of Korea Water Resources Association
      • /
      • v.54 no.7
      • /
      • pp.495-507
      • /
      • 2021
    • With the recent industrial development, accidental pollution in riverine environments has frequently occurred. It is thus necessary to simulate pollutant transport and dispersion using water quality models for predicting pollutant residence times. In this study, we conducted a field experiment in a meandering reach of the Sum River, South Korea, to validate the field applicability and prediction accuracy of RAMS+ (River Analysis and Modeling System+), which is a two-dimensional (2D) stream flow/water quality analysis program. As a result of the simulation, the flow analysis model HDM-2Di and the water quality analysis model CTM-2D-TX accurately simulated the 2D flow characteristics, and transport and mixing behaviors of the pollutant tracer, respectively. In particular, CTM-2D-TX adequately reproduced the elongation of the pollutant cloud, caused by the storage effect associated with local low-velocity zones. Furthermore, the transport model effectively simulated the secondary flow-driven lateral mixing at the meander bend via 2D dispersion coefficients. We calculated the residence time for the critical concentration, and it was elucidated that the calculated residence times are spatially heterogeneous, even in the channel-width direction. The findings of this study suggest that the 2D water quality model could be the accidental pollution analysis tool more efficient and accurate than one-dimensional models, which cannot produce the 2D information such as the 2D residence time distribution.

    Evaluation of Debonding Defects in Railway Concrete Slabs Using Shear Wave Tomography (전단파 토모그래피를 활용한 철도 콘크리트 궤도 슬래브 층분리 결함 평가)

    • Lee, Jin-Wook;Kee, Seong-Hoon;Lee, Kang Seok
      • Journal of the Korea institute for structural maintenance and inspection
      • /
      • v.26 no.3
      • /
      • pp.11-20
      • /
      • 2022
    • The main purpose of this study is to investigate the applicability of the shear wave tomography technology as a non-destructive testing method to evaluate the debonding between the track concrete layer (TCL) and the hydraulically stabilized based course (HSB) of concrete slab tracks for the Korea high-speed railway system. A commercially available multi-channel shear wave measurement device (MIRA) is used to evaluate debonding defects in full-scaled mock-up test specimen that was designed and constructed according to the Rheda 200 system. A part of the mock-up specimen includes two artificial debonding defects with a length and a width of 400mm and thicknesses of 5mm and 10mm, respectively. The tomography images obtained by a MIRA on the surface of the concrete specimens are effective for visualizing the debonding defects in concrete. In this study, a simple image processing method is proposed to suppress the noisy signals reflected from the embedded items (reinforcing steel, precast sleeper, insert, etc.) in TCL, which significantly improves the readability of debonding defects in shear wave tomography images. Results show that debonding maps constructed in this study are effective for visualizing the spatial distribution and the depths of the debondiing defects in the railway concrete slab specimen.

    Examination for Controlling Chloride Penetration of Concrete through Micro-Cracks with Surface Treatment System (표면도장공법을 적용한 미세균열 콘크리트의 염소이온 침투 제어 특성)

    • Yoon, In-Seok;Chae, Gyu-Bong
      • KSCE Journal of Civil and Environmental Engineering Research
      • /
      • v.28 no.5A
      • /
      • pp.729-735
      • /
      • 2008
    • For well-constructed concrete, its service life is a long period and it has an enough durability performance. For cracked concrete, however, it is clear that cracks should be a preferential channel for the penetration of aggressive substance such as chloride ions accoding to author's previous researches. Even though crack width can be reduced due to the high reinforcement ratio, the question is to which extend these cracks may jeopardize the durability of cracked concrete. If the size of crack is small, surface treatment system can be considered as one of the best options to extend the service life of concrete structures exposed to marine environment simply in terms of cost effectiveness versus durability performance. Thus, it should be decided to undertake an experimental study to deal with the effect of different types of surface treatment system, which are expected to seal the concrete and the cracks to chloride-induced corrosion in particular. In this study, it is examined the effect of surfaced treated systems such as penetrant, coating, and their combination on chloride penetration through microcracks. Experimental results showed that penetrant can't cure cracks. However, coating and combined treatment can prohibit chloride penetration through cracks upto 0.06 mm, 0.08 mm, respectively.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.