• 제목/요약/키워드: Chamber light

검색결과 357건 처리시간 0.031초

선박용 LED Chamber Light의 열 및 광학 특성에 관한 연구 (A Study on the Thermal and Optical Properties of a LED Chamber Light for Vessels)

  • 김상현;이도엽;김우성;장낙원
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.57-63
    • /
    • 2015
  • Recently, LED is widely used in the kinds of display devices or lighting. In this paper, we fabricated LED chamber light for naval vessels to replace to conventional chamber light using incandescent lamp. The LED package of chamber light was designed with luminous intensity of 5.5 cd, color temperature of $6,000{\pm}500K$, forward voltage of 3~3.2 V and input current of 60 mA. A LED module was composed of 36 LED packages and metal PCB. The VF and luminous intensity of LED package were getting down when temperature increased. The temperature of LED chamber light was measured by changing the number of LED package and applied current for one hour when an electric current flow. The heat transfer capability have been improved by using metal PCB. The power consumption of LED chamber light reduced by 86% compared to the conventional chamber light using incandescent lamp.

부실식 정적연소실내 연소특성에 관한 연구 (II) 임계연락공의 형상변화에 따른 연소촉진효과 (Combustion Characteristics in a Constant Volume Combustion Chamber with Sub-Chamber (II) Effect of Combustion Promotion with Configuration Change of the Critical Passagehole)

  • 김봉석;권철홍;류정인
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2611-2623
    • /
    • 1993
  • To construct the design back data for a lean-burn gas engine, we investigated the combustion characteristics in the main chamber using a constant volume combustion chamber with subchamber. The combustion characteristics with configuration change of the critical passageholes have been studied by taking pressure data, schlieren photograph, ion current and light emission signal of flame. Heat release rate with various critical passageholes also have been analysed by using the combustion model of a prechamber diesel engine. It was found that combustion characteristics in the main combustion chamber were greatly influenced by the geometric configurations of critical passagehole.

LED Chamber System을 이용한 광질 및 광조사 방법 제어가 국화 배양소식물체의 생장에 미치는 영향 (Effects of Light Quality and Lighting Type Using an LED Chamber System on Chrysanthemum Growth and Development Cultured In Vitro)

  • 허정욱;이용범;장유섭;이정택;이덕배
    • 한국환경농학회지
    • /
    • 제29권4호
    • /
    • pp.374-380
    • /
    • 2010
  • 본 연구에서는 농촌진흥청에서 개발한 LED Chamber System을 이용하여 명기시간 동안 광질과 광조사 방법 제어가 단절단엽의 국화 배양소식물체(Dendranthema grandiflorum L., cv. 'Cheonsu')의 생장에 미치는 영향을 검토하였다. 실험은 청색, 적색 및 녹색의 단일광질 또는 청색+적색, 청색+녹색 및 적색+녹색의 혼합광질 조건하에서 이들 광질을 명기 16시간 동안 연속적으로 또는 초당 50회 간격과 분당 20초간격으로 간헐적으로 제어하면서 42일간 수행하였다. 총 일장을 4시간 단축한 분당 20초 간격의 간헐조사는 관행의 형광등 연속조사에 비해 국화의 절간길이 신장에 의한 신초신장을 촉진하였으나, 배양소식물체의 양적생장은 연속광 처리에 의해 유의하게 증가하였다. 한편, 명기동안 녹색광을 초당 50회 간격으로 간헐제어한 경우 연속조사에 비해 건물중이나 엽면적 증대와 같은 양적생장은 억제되었으나 형태적인 면에서의 절간신장은 촉진되었다. 따라서, LED Chamber System을 이용한 광질이나 광조사 방법의 제어는 관행의 형광등 이용 연속조사에 비해 명기시간 단축에 의한 전력소모량 감소 및 기내 배양소식물체의 생장이나 형태제어에 효과적인 배양기술로 이용 가능할 것으로 판단된다.

UVLED 광원을 이용한 광촉매 VOC 제거 특성 평가시 온도에 따른 농도 변화에 관한 연구 (A Study of the Temperature Dependency for Photocatalytic VOC Degradation Chamber Test Under UVLED Irradiations)

  • 문지연;이규상;김선민
    • Korean Chemical Engineering Research
    • /
    • 제53권6호
    • /
    • pp.755-761
    • /
    • 2015
  • 광촉매의 VOC 제거 특성 평가에 관한 최근의 연구는 온도 변화가 거의 없는 상태에서 실시되었다. 온도 변화를 적게하기 위해 광량이 높은 UVLED를 챔버 위부에 배치하게 되면 광촉매와의 거리가 멀어져 그만큼 효율이 감소할 수 밖에 없으며 광촉매의 효율 향상을 위해서는 광원과 광촉매의 거리를 가까이 해야 할 필요가 있다. 본 연구에서는 UVLED 광원과 광촉매와의 거리를 가까이 두어 온도가 변하는 VOC 제거 시스템을 제작하였다. 광촉매로는 자외선 광원에서 반응하는 상용 $TiO_2$와 vanadium 이온을 도핑시킨 $TiO_2$를 사용하였으며 제작된 챔버를 이용하여 광촉매 효율을 평가하였다. VOC 제거 평가 시 테스트 전후 온도는 약 $20^{\circ}C$ 상승하여 UVLED 광원에 의해 변화된 온도로 VOC의 농도를 보정하여 온도에 따른 VOC 제거 효율 변화를 확인하였다. 보정 전후의 제거 효율을 비교하면 43~46%의 차이를 보였다. 챔버 내 온도 상승이 p-xylene의 농도 변화에 큰 영향을 주며 이를 보정하여 광촉매의 VOC 제거 효율을 평가할 필요가 있음을 확인할 수 있었다.

광도가 서울 대기의 오존 생성 및 에어로졸 수 농도에 미치는 영향 (Effect of light intensity on the ozone formation and the aerosol number concentration of ambient air in Seoul)

  • 배귀남;박주연;김민철;이승복;문길주;김용표
    • 한국입자에어로졸학회지
    • /
    • 제4권1호
    • /
    • pp.9-20
    • /
    • 2008
  • The effect of light intensity on the ozone formation and the aerosol number concentration during the photochemical reactions of ambient air was investigated in an indoor smog chamber. The smog chamber consists of a housing, 64 blacklights, and a $2.5-m^3$ reaction bag made of Teflon film. The bag was filled with the unfiltered ambient air in Seoul from January 10 to March 18, 2002. In this work, the photolysis rate of $NO_2$, $k_1$ was used as an index of light intensity. Three levels of light intensity were controlled by changing the number of blacklights turned on among 64 blacklights: $0.29min^{-1}$ (50%), $0.44min^{-1}$ (75%), $0.57min^{-1}$ (100%). The ozone concentration increased rapidly within 10 minutes after irradiation irrespective of light intensity, thereafter it increased linearly during the irradiation. The ozone production rate seems to be dependent on both the light intensity and the quality of ambient air introduced into the reaction bag. The change in aerosol number concentration also depended on both the light intensity and the ambient air quality, especially aerosol size distribution. Based on the initial ambient aerosol size distributions, the photochemical potential for aerosol formation and growth is classified into two cases. One is the case showing aerosol formation and growth processes, and the other is the case showing no apparent change in particle size distribution.

  • PDF

Analysis of the experimental cooling performance of a high-power light-emitting diode package with a modified crevice-type vapor chamber heat pipe

  • Kim, Jong-Soo;Bae, Jae-Young;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권8호
    • /
    • pp.801-806
    • /
    • 2015
  • The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

광학입자센서 내 유동장과 측정영역이 측정효율에 미치는 영향 (Effect of Flow Field and Detection Volume in the Optical Particle Sensor on the Detection Efficiency)

  • 김영길;전기수;김태성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3162-3167
    • /
    • 2007
  • The OPS (Optical Particle Sensor) using light scattering from the particles (real-time measurement without physical contact to the particles) can be used for cleanroom or atmospheric environment monitoring. For particles smaller than 300 nm, the detection efficiency becomes lower as scattered light decreases with particle size. To obtain higher detection efficiency with small particles, the flow field in particle chamber and the detection volume should be designed optimally to achieve maximum scattered light from the particles. In this study, a commercial computational fluid dynamics software FLUENT was used to simulate the gas flow field and particle trajectories with various optical chamber designs for 300 nm PSL particle. For estimation of laser viewing volume, we used a commercial computational optical design program ZEMAX. The results will be a great help in the development of OPS which can measure small particles with higher detection efficiency.

  • PDF

투과손실 예측을 위한 유한요소 해석과 소형 잔향실 실험의 비교에 검증에 관한 연구 (Study of Sound Transmission Characteristics of using a Scale Reverberation Chamber and vibro acoustic FEM)

  • 이준헌;김범수;김관주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.92-95
    • /
    • 2011
  • The walls of modern train cars are required to have higher transmission loss since modern train have had high speed and light weight. The method based on Reverberation Chamber like KS F 2808 could be used to measure transmission loss. However, this method has difficulty in that constrained Standard of it requires extremely large facilities. Recently, the method based on Scale Reverberation Chamber is used as an alternative to Reverberation Chamber. The method of Scale Reverberation Chamber is known to be small and economical but it provides standing wave that directly influences measurement error. Therefore, this research is focus on predicting standing waves based on method of FFM and reducing measurement error by changing shape of chamber.

  • PDF

LED-Equipped Y-Maze Chamber에 대한 긴털가루응애 성충의 방제효과 (Controlling Tyrophagus putrescentiae Adults in LED-Equipped Y-Maze Chamber)

  • 이상민;이정빈;이회선
    • Journal of Applied Biological Chemistry
    • /
    • 제58권2호
    • /
    • pp.101-104
    • /
    • 2015
  • 긴털가루응애 성충을 청색(470 nm), 녹색(520 nm), 황색(590 nm)과 적색(625 nm) light-emitting diode (LED)에서 파장별 광량을 20, 40 및 60 lx로 달리하여 주광성 행동반응 판별장치(LED-equipped Y-maze chamber)에서 상업적 양성대조구 BLB와 유인활성을 비교하였다. 긴털가루응애는 사용된 청색, 녹색, 황색 및 적색 LED 파장과 20, 40 및 60 lx 광량에서 특별한 행동반응특성을 발견하지 못하였으며, 양성대조구로 이용된 BLB에서도 긴털가루응애는 음성/양성주광성 반응을 보이지 않았다. 이러한 결과를 근거로 긴털가루응애는 LED 주광성 행동반응 판별장치에서는 친환경적 해충방제 가능성을 제시하지 못했다.

온도와 광도가 톨루엔-NOx-공기 혼합물의 광산화 반응에 미치는 영향의 비교 (Comparison of Temperature and Light Intensity Effects on the Photooxidation of Toluene-NOx-Air Mixture)

  • 주옥정;배귀남;최지은;이승복;김영성;문길주;윤순창
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.353-363
    • /
    • 2007
  • To differentiate temperature effect from the light intensity effect on the formation of secondary products during the photooxidation of toluene-$NO_x$-air mixtures, steady-state air temperature was changed from $20^{\circ}C\;to\;33^{\circ}C$ at the same light intensity of $0.39min^{-1}$ in an indoor smog chamber. Smog chamber consisted of 64 blacklights and a $5.8m^3$ reaction bag made of Teflon film. Air temperature was controlled by an air-conditioning system. The starting time for rapid conversion of NO to $NO_2$ was slightly delayed with decreasing air temperature. In contrast to light intensity effect, the ozone formation time and the ozone production rate were insensitive to air temperature. Although the formation time for secondary organic aerosols was not changed, the particle number concentration increased with temperature. However, the newly formed secondary organic aerosol mass at lower temperature was higher than that at higher temperature. Since light intensity significantly affected the starting time and quantity of ozone and aerosol formation, it is considered that the temperature could contribute partly the quantity of aerosol formation during the photooxidation of toluene-$NO_x$-air mixtures.