• Title/Summary/Keyword: Chairside

Search Result 38, Processing Time 0.03 seconds

Dental biomaterials for chairside CAD/CAM: State of the art

  • Lambert, Hugo;Durand, Jean-Cedric;Jacquot, Bruno;Fages, Michel
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.486-495
    • /
    • 2017
  • The wide use of chairside CAD/CAM restorations has increased the diversity of the restorative material. For the practitioner, the selection of the appropriate material is difficult amongst the variety offered by the market. Information on the characteristics of the products can be difficult to assess due to the lack of up-to-date classification and the lack of reliability of manufacturer's advertising. The purpose of this article is to structure the data on restorative materials provided by various sources in order for the practitioner to choose the product most suited to the clinical situation. The objective is to classify chairside CAD/CAM materials and to define their characteristics and indications.

Autogenous fresh demineralized tooth graft prepared at chairside for dental implant

  • Kim, Eun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.8.1-8.6
    • /
    • 2015
  • Background: This study aimed to evaluate the clinical usefulness of autogenous fresh demineralized tooth (auto-FDT) graft prepared at the chairside for alveolar bone grafting during dental implant surgery. Methods: In total, 38 patients requiring both tooth extraction (for endodontic or periodontal reasons or third molar extraction) and alveolar bone regeneration for dental implant placement were included. Within 2 h after clean extraction, the teeth were prepared at the chairside to serve as bone graft material. In the same sitting, blocks or chips of this graft material were used to reconstruct defects at the osteotomy site simultaneously with or before implant placement. Twelve months after prosthesis fabrication and placement, the clinical findings and implant success rates were evaluated. Histological studies were randomly conducted for selected cases. Results: Clinical evaluation showed favorable wound healing with minimal complications and good bone support for the implants. No implant was lost after 12 months of function following prosthetic rehabilitation. Histological examination revealed new bone formation induced by the graft material. Conclusions: Chairside preparation of autogenous fresh demineralized teeth after extraction can be a useful alternative to the use of autogenous bone or other graft materials for the immediate reconstruction of alveolar bone defects to facilitate subsequent implant placement.

An alternative treatment option for a bony defect from large odontoma using recycled demineralization at chairside

  • Lee, JuHyon;Lee, Eun-Young;Park, Eun-Jin;Kim, Eun-Suk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Odontoma is the most common odontogenic benign tumor, and the treatment of choice is generally surgical removal. After excision, bone grafts may be necessary depending on the need for further treatment, or the size and location of the odontoma. Although the osteogenic capacity of a demineralized tooth was verified as early as 1967 by Urist and many other investigators, the cumbersome procedure, including a long demineralization time, may be less than comfortable for clinicians. A modified ultrasonic technology, with periodic negative pressure and temperature control, facilitated rapid and aseptic preparation of demineralized teeth for bone grafts. This approach reduces the demineralization time dramatically (${\leq}80$ minutes), so that the graft material can be prepared chairside on the same day as the extraction. The purpose of this article is to describe two cases of large compound odonotomas used as graft material prepared chairside for enucleation-induced bony defects. These two clinical cases showed favorable wound healing without complications, and good bony support for future dental implants or orthodontic treatment. Finally, this report will suggest the possibility of recycling the benign pathologic hard tissue as an alternative treatment option for conventional bone grafts in clinics.

Effect of Gap between Expected Job and Performed Job on Turnover Intention and Job Satisfaction in Clinical Dental Hygienists (치과위생사의 기대업무와 수행업무 격차가 이직의도와 직무만족도에 미치는 영향)

  • Choi, Ha-Na;Bae, Hyun-Sook;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.11 no.5
    • /
    • pp.463-469
    • /
    • 2011
  • The purpose of this study was to investigate effect of gap between expected job and performed job on job satisfaction and turnover intention in clinical dental hygienists. A total 292 hygienist in dental hospitals and dental offices in nationwide completed a questionnaire on their daily routine job and job which they expected and measured gap between expected job and performed job, such as chairside assisting, preventive care, consultation, reception. The study showed the gap on chairside assisting job among age, career and showed the gap on consultation among age, education, career and showed the gap on reception among age, career. gap on chairside assisting, salary satisfaction, personal day affected job satisfaction and gap on chairside assisting, children, salary satisfaction affected turnover intention. The study showed that salary satisfaction and gap on chairside assisting associated with turnover intention and job satisfaction. Personal day affected job satisfaction but did not affect turnover intention.

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Association of chairside salivary aMMP-8 findings with periodontal risk assessment parameters in patients receiving supportive periodontal therapy

  • Schmalz, Gerhard;Kummer, Max Kristian;Kottmann, Tanja;Rinke, Sven;Haak, Rainer;Krause, Felix;Schmidt, Jana;Ziebolz, Dirk
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.251-260
    • /
    • 2018
  • Purpose: The aim of this retrospective cross-sectional study was to evaluate whether salivary findings of active matrix-metalloproteinase 8 (aMMP-8) chairside (point of care; POC) tests were associated with periodontal risk assessment parameters in patients receiving supportive periodontal therapy (SPT). Methods: A total of 125 patients receiving regular SPT were included, and their records were examined. The following inclusion criteria were used: a diagnosis of chronic periodontitis, at least 1 non-surgical periodontal treatment (scaling and root planning) with following regular SPT (minimum once a year), at least 6 remaining teeth, and clinical and aMMP-8 findings that were obtained at the same appointment. In addition to anamnestic factors (e.g., smoking and diabetes), oral hygiene indices (modified sulcus bleeding index [mSBI] and approximal plaque index), periodontal probing depth simultaneously with bleeding on probing, and dental findings (number of decayed, missing, and filled teeth) were recorded. Salivary aMMP-8 levels were tested using a commercial POC test system (Periomarker, Hager & Werken, Duisburg, Germany). Statistical analysis was performed using the t-test, Mann-Whitney U test, Fisher's exact test, and ${\chi}^2$ test, as appropriate (P<0.05). Results: Only the mSBI was significantly associated with positive salivary aMMP-8 findings (aMMP-8 positive: $27.8%{\pm}20.9%$ vs. aMMP-8 negative: $18.0%{\pm}14.5%$; P=0.017). No significant associations were found between aMMP-8 and smoking, diabetes, periodontal parameters, or parameters related to the maintenance interval (P>0.05). Conclusions: Salivary aMMP-8 chairside findings were not associated with common parameters used for periodontal risk assessment in patients receiving SPT. The diagnostic benefit of POC salivary aMMP-8 testing in risk assessment and maintenance interval adjustment during SPT remains unclear.

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.

Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging

  • Laura Vitoria Rizzatto;Daniel Meneghetti;Marielle Di Domenico;Julia Cadorin Facenda;Katia Raquel Weber;Pedro Henrique Corazza;Marcia Borba
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.136-144
    • /
    • 2023
  • PURPOSE. The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CADCAM materials after aging. MATERIALS AND METHODS. A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS. The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION. The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.