• Title/Summary/Keyword: Cervical length measurement

Search Result 17, Processing Time 0.022 seconds

Study of Radiographic Measurement on Cervical Misalignments in Scalenus Anticus Syndrome (사각근 증후군 환자의 경추 부정렬에 관한 방사선 사진 분석)

  • Keum, Dong-Ho;Kang, Ji-Hun
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.45-56
    • /
    • 2007
  • Objectives : We investigated the possibility of cervical spine misalignment caused by scalenus anticus syndrome to find out how it affects cervical spine misalignments. Methods : 28 patients with scalenus anticus syndrome (sample group), along with 21 participants without neck pain (control group), who attended the Dept. of Oriental Rehabilitation Medicine, College of Oriental Medicine, Dong-guk University from the 20th of June to the 30th of November, 2006 were investigated. After researching misalignments through neutrality, flexion and extension lateral x-ray examination views, we measured the difference of each length of cervical spine misalignment. We analyzed the relationships among the neutrality lateral, flexion lateral and extension lateral positions. Results : We found with statistical significance that there were differences in length of cervical spine misalignments between the sample and control groups. Furthermore, we found that C3 and C4 vertebra bodies were shown in lateral neutrality position, only C3 vertebra body in flexion lateral position, and C2, C3, and C4 vertebra bodies in extension lateral position. Conclusions : It is considered that scalenus anticus syndrome could increase cervical spine misalignment which could be a factor in causing cervical spine disease.

  • PDF

Biomechanical Effectiveness and Anthropometric Design Aspects of 3-dimensional Contoured Pillow

  • Kim, Jong Hyun;Won, Byeong Hee;Sim, Woo Sang;Jang, Kyung Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.503-517
    • /
    • 2016
  • Objective: The aim of this study was to evaluate the effectiveness of 3 dimensional contoured pillow through analyzing contact pressure and to suggest its design guidelines through analyzing the posture of head and neck area. Background: The quality of sleep is a very important factor closely related with human's health. To improve the quality of sleep, the verification of design factors affecting the posture of the head and neck is needed, and a pillow design that can induce proper posture is required. Method: This study measured the contact pressures of the two reference groups (bead and cotton pillows) as a method to evaluate the design effectiveness of the contoured pillow. This study proposed 3-dimensional design guidelines by drawing anthropometry (head length) affecting cervical curvature angle (CCA) through the measurement of the participants' cervical curvature angles. Results: In the design effectiveness evaluation, the contact pressure of cervical region was higher than that of a reference group (cotton pillow), and contract area increased, and contract pressure decreased in the shape distributing the occipital region's body pressure. This study proposed pillow's cervical supporting height by percentile of a head length [head length (%tile) (cervical supporting height) affecting the posture of the head and neck: 14.6cm (5%tile) (6.2cm), 15.5cm (25%tile) (6.7cm), 16.4cm (50%tile) (7.1cm), and 19.3cm (75%tile) (8.9cm)]. Conclusion: This study confirmed the contoured pillow's design effectiveness maintaining cervical angle comfortable to sleep with the shape supporting the cervical vertebrae and by reducing the contact load of the occipital region. Also, this study proposed pillow design guidelines based on the 3-dimensional contoured pillow design effectiveness, through which the study laid the foundation for pillow design in a systematic method. Application: The results of this study are expected to be utilized as the basis data by which the optimum pillow type and pillow design according to main percentile can be standardized.

Sizing System Development of Korean Structural Firefighting Protective Clothing (한국 소방용 방화복의 치수체계 개발)

  • Han, Sul-Ah;Nam, Yun-Ja;Choi, Young-Lim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.5
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

Study on body measurement of fetuses and neonates in Korean native goats (한국재래산양(韓國在來山羊)의 태아(胎兒) 및 신생자(新生仔)의 체적측정치(體尺測定値)에 관(關)한 연구(硏究))

  • Kim, Chong-sup;Choe, Sang-yong;Chung, Hyon-sik;Kim, Taeg-seog
    • Korean Journal of Veterinary Research
    • /
    • v.28 no.2
    • /
    • pp.213-219
    • /
    • 1988
  • The measurement was investigated with 18 heads of fetus(60, 90, 120 days of gestation) and neonate in Korean native goats. The results were summerized as follows: 1. The crown-rump length of fetuses at 60, 90, 120 days of gestation and neonate was 8.71, 20.83, 31.10 and 34.93 cm, respectively. 2. The length of small intestine at 60, 90, 120 days of gestation and neonate was 32.28, 157.10, 303.52 and 457.06 cm, respectively. 3. The length of large intestine at 60, 90, 120 days of gestation and neonate was 9.20, 37.70, 82.06 and 94.46 cm, respectively. 4. The ratio of intestinal length to crown-rump length at 60, 90, 120 days of gestation and neonate was 4.76, 9.45, 12.40 and 15.79 times, respectively. 5. At 60 days of gestation, the total length of the vertebral column was $7.40{\pm}0.72cm$, The mean length of each segment of the vertebral column was $1.55{\pm}0.20cm$ in cervical, $2.29{\pm}0.21cm$ in thoracic, $1.46{\pm}0.10cm$ in lumbar, $0.51{\pm}0.04cm$ in sacral and $1.59{\pm}0.17cm$ in coccygeal vertebrae. 6. At 90 days of gestation, the total length of the vertebral column was $16.52{\pm}0.80cm$. The mean length of each segment of the vertebral column was $3.72{\pm}0.12cm$ in cervical, $5.09{\pm}0.26cm$ in thoracic, $3.22{\pm}0.04cm$ in lumbar, $1.97{\pm}0.03cm$ in sacral and $2.64{\pm}0.35cm$ in coccygeal vertebrae. 7. At 120 days of gestation, the total length of the vertebral column was $26.35{\pm}0.34cm$. The mean length of each segment of the vertebral column was $6.09{\pm}0.16cm$ in cervical, $7.81{\pm}0.07cm$ in thoracic, $5.08{\pm}0.07cm$ in lumbar, $3.07{\pm}0.02cm$ in and $4.31{\pm}0.02cm$ in coccygeal vertebrae. 8. In the neonate, the total length of the vertebral column was $32.41{\pm}1.57cm$. The mean length of each segment of vertebral was $7.70{\pm}0.25cm$ in cervical, $9.97{\pm}0.68cm$ in thoracic, $5.58{\pm}0.44cm$ in lumbar, $3.85{\pm}0.15cm$ in sacral and $5.05{\pm}0.06cm$ coccygeal vertebrae. 9. The chest girth at 60, 90, 120 days of gestation and neonate was $6.13{\pm}0.51$, $13.45{\pm}0.84$, $20.28{\pm}1.53$ and $22.94{\pm}1.75cm$, respectively. 10. The head length at 60, 90, 120 days of gestation and neonate was $2.93{\pm}0.07$, $6.67{\pm}0.13$, $8.84{\pm}0.51$ and $9.76{\pm}0.44cm$, respectively. 11. The width of the head at 60, 90, 120 days of gestation and neonate was $2.20{\pm}0.13$, $4.45{\pm}0.11$, $5.33{\pm}0.20$ and $5.51{\pm}0.32cm$, respectively.

  • PDF

A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination (경추 정면 검사에서 방사선 입사각에 관한 연구)

  • Jeung, Seung-Woon;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol;Park, Mi-Ja
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.83-92
    • /
    • 2012
  • In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were $15.9^{\circ}$, the twenties were $16.9^{\circ}$, the thirties were $16.6^{\circ}$, the forties were $16.2^{\circ}$, the fifties were $15.9^{\circ}$, and the sixties were $14.5^{\circ}$, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by $2^{\circ}$. When the incidence angle statistically analyzed with measurement of average length of cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

Effects of San-Yin-Jiao(SP6) Acupressure on Labor Pain, Delivery Time in Women during Labor (삼음교(SP6)지압이 산부의 분만통증, 분만소요시간에 미치는 효과)

  • 이미경
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.6
    • /
    • pp.753-761
    • /
    • 2003
  • Purpose: The study was done to examine the effects of San- Yin-Jiao(SP6) acupressure treatment on subjective labor pain, length of delivery time in women during labor. Method: The study design was a randomized controlled clinical trial study using a double-blinded method. Data were collected using a structured questionnaire, a subjective labor pain scale and measurement of delivery time. The experimental group(n=29) was received SP6 acupressure and control group(n=29), SP6 touch for the duration of each uterine contraction, during 30 minutes after 3cm dilatation of cervical os. Result: The subjective labor pain scores was significantly different between the two groups(p=0.042). The total length of delivery time in the group which had the SP6 acupressure was shorter than SP6 touch group (p=0.036). Conclusion: These findings showed that SP6 acupressure was effective related to labor pain, length of time for delivery. SP6 acupressure during labor could be applied as an effective nursing treatment.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

Comparative Analysis of Cervical Lateral Mass Screw Insertion among Three Techniques in the Korean Population by Quantitative Measurements with Reformatted 2D CT Scan Images : Clinical Research

  • Cho, Jae-Ik;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.3
    • /
    • pp.124-130
    • /
    • 2008
  • Objective : Our purpose of this study is to compare insertion angles and screw lengths from Roy-Camille, Magerl, and our designed method for cervical lateral mass screw fixation in the Korean population by quantitative measurement of reformatted two dimensional (2D) computed tomography (CT) images. Methods : We selected thirty Korean patients who were evaluated with thin section CT scans and reconstruction program to obtain reformatted 2D-CT images of the transversal plane passing the cranio-caudal angle using three different techniques. We measured the minimum angle to avoid vertebral artery (VA) injury, the ideal angle and depth for bicortical screwing of cervical lateral mass. Morphometric measurements of the lateral masses from C3-C7 were also taken. Results : In all three techniques, the mean safety angles from the VA were less than 8 degrees and the necessary depth of the screw was about 14 mm for safety to the VA and for the bicortical purchase. In our designed technique, the mean $\beta$ angles of each level from C3 to C7 were 29.0. 29.8. 29.5. 26.3. and 23.9 degrees, respectively. Conclusion : Results of this study and data from the literature indicate that differences may exist between the Korean and Western people in the length and angle for ideal lateral mass screw fixation. In addition, our technique needs further cadaveric and clinical study for safety and efficacy for being performed as alternative method for cervical lateral mass fixation.

The Study of Pain-Increased Factors on Cervical and Shoulder Pain by 3 Dimensional Moire Scanner (3차원 체형 측정기를 통한 경.견부 통증요인 분석)

  • Yang, Hoe-Song;Heo, Ja-Eun;Kim, Bo-Young;Seo, Dong-Yong;An, Chang-Heon;Yang, Hun-Kyung;Jeong, Chan-Ju;Lee, Hyoung-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to find out factors(shoulder level, acromion-occipital length, spine alignment, spine-scapula inferior angle length) of pain of neck & shoulder by 3 Dimensional Moire Scanner. 50 female student s aged 20 to 25 years old participated who lived in Sun-cheon si Jeonnam. They were examined with three measurement methods(Visual Analogue Scale : VAS, Algometer, 3 Dimensional Moire Scanner(IBS-2000). According to the results of multiple regression analysis. 1) There was a significant difference with shoulder level and spine-scapula inferior angle based on VAS. 2) There was a significant difference with shoulder level based of Algometer measurement value in Rhomboid muscles.

  • PDF